Giannis Papadopoulos

Mr. Giannis Papadopoulos

Deparment of Mechanical Engineering, University of Western Macedonia, Kozáni, Dytikí Makedonía, Greece
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2024 in Environmental Research
Verified
Journal Article
Open access
Pedro BrancoPedro Branco
Pedro Branco
Sofia SousaSofia Sousa
Sofia Sousa
MDMarzena Roza Dudzińska
Marzena Roza Dudzińska
DRDuygu Gazioglu Ruzgar
Duygu Gazioglu Ruzgar
MMMustafa Mutlu
Mustafa Mutlu
AWAnnemarie Weersink
Annemarie Weersink
Indoor air quality (IAQ) in educational facilities is crucial due to the extended time students spend in those environments, affecting their health, academic performance, and attendance. This paper aimed to review relevant parameters (building characteristics and factors related with occupancy and activities) for assessing IAQ in educational facilities, and to identify the parameters to consider when performing an IAQ monitoring campaign in schools. It also intended to identify literature gaps and suggest future research directions. A narrative literature review was conducted, focusing on seven key parameters: building location, layout and construction materials, ventilation and air cleaning systems, finishing materials, occupant demographics, occupancy, and activities. The findings revealed that carbon dioxide (CO2) levels were predominantly influenced by classroom occupancy and ventilation rates, while particulate matter (PM) concentrations were significantly influenced by the building's location, design, and occupant activities. Furthermore, this review highlighted the presence of other pollutants, such as trace metals, polycyclic aromatic hydrocarbons (PAHs), carbon monoxide (CO), nitrogen dioxide (NO2), ozone (O3), and radon, linking them to specific factors within the school environment. Different IAQ patterns, and consequently different parameters, were observed in various school areas, including classrooms, canteens, gymnasiums, computer rooms, and laboratories. While substantial literature exists on IAQ in schools, significant gaps still remain. This study highlighted the need for more studies in middle and high schools, as well as in other indoor microenvironments within educational settings beyond classrooms. Additionally, it underscored the need for comprehensive exposure assessments, long-term studies, and the impacts of new materials on IAQ including the effects of secondary reactions on surfaces. Seasonal variations and the implications of emerging technologies were also identified as requiring further investigation. Addressing those gaps through targeted research and considering the most updated standards and guidelines for IAQ, could lead to define more effective strategies for improving IAQ and safeguarding the students' health and performance.

25 April 2022 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
GPGiannis Papadopoulos
Giannis Papadopoulos
ETEvangelos I. Tolis
Evangelos I. Tolis
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
Investigation of Indoor Environmental Quality (IEQ) in various types of buildings has currently evolved into a rather intense research activity. IEQ refers to the acceptable levels of thermal, visual and acoustic comfort in addition to Indoor Air Quality (IAQ). In the proposed work, a systematic measurement campaign in university classrooms in the Educational School of the University of Western Macedonia, Florina, Greece, is presented; the campaign was performed by the end of the Spring Semester, in free-running classrooms. Measurements include thermal comfort parameters, as well as IAQ ones, namely volatile organic compounds (VOCs), CO2 and NO2 concentration. Lighting and acoustic measurements are also performed, contributing to an integrated IEQ assessment. As far as thermal comfort is concerned, a questionnaire survey aims at providing insight into the validity of the examined comfort models. i.e. Fanger’s and adaptive one. CFD analysis, according to the DesignBuilder software, allows the investigation of spatial phenomena in terms of thermal comfort, as well as the evaluation of the effect of different scenarios regarding the degree of crowding in the classes and windows opening. All in all, the proposed analysis represents an integrated experimental and simulation approach, for the evaluation of IEQ of a demanding space.

1 January 2020 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
GPGiannis Papadopoulos
Giannis Papadopoulos
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
ETEvangelos Tolis
Evangelos Tolis
Investigation of thermal comfort in various types of buildings is a rather intense research activity by recent years. Besides thermal comfort, the Indoor Air Quality (IAQ) is also important for the sensation of humans in indoor environments, as well as for their health. In the proposed work, a systematic measurement campaign in university classrooms in the Educational School of the University of Western Macedonia, Florina, Greece, is presented; the campaign was performed through winter time, noting that the University lies on the coldest thermal zone on a country level. Measurements include thermal comfort parameters, as well as IAQ ones, namely volatile organic compounds (VOCs), aldehydes and NO2concentration.As far as thermal comfort is concerned, Fanger’s thermal comfort indices are calculated, on the basis of the measured data; a comparison is made through the support of questionnaires investigating the actual thermal comfort level of the students while being in the classrooms, aiming at providing information on an adaptive sensation level. In terms of air quality, measurements are made both indoors and outdoors, allowing the determination of indoor/outdoor correlations.

9 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
PTPanagiotis Tzimas
Panagiotis Tzimas
Evangelos TolisEvangelos Tolis
Evangelos Tolis
GPGiannis Papadopoulos
Giannis Papadopoulos
AAAristeidis Afentoulidis
Aristeidis Afentoulidis
Manolis SouliotisManolis Souliotis
Manolis Souliotis
Wineries present significant interest on a research level, combining Indoor Air Quality (IAQ) issues related with substances emitted through the wine production, as well as the need for minimizing conventional energy consumption (optimizing energy performance). In the proposed work, experimental and theoretical analyses are presented which aim to achieve both targets, that of improved indoor climate and energy performance. An extensive measurement campaign was implemented, regarding indoor climate thermal parameters, as well as concentration of substances (CO2, VOCs, NO2) affecting IAQ. The results of the parameters were exploited for the assessment of indoor climate; moreover, data from indoor thermal parameters together with values of specific parameters related to the efficiency of the individual devices were utilized in the development of the energy model. The model was used to formulate and evaluate proposals for reducing the energy consumption of the winery. The proposals include the use of Renewable Energy Sources (RES) and, in particular, the installation of a photovoltaic array on the roof of the premises. Finally, an economic and technical study was carried out to determine the performance of the suggested interventions and the expected payback period.

10 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
GPGiannis Papadopoulos
Giannis Papadopoulos
Evangelos TolisEvangelos Tolis
Evangelos Tolis
Giorgos PanarasGiorgos Panaras
Giorgos Panaras
This study presents a combined investigation of indoor environmental conditions and energy performance in a naturally ventilated aquatic center in Western Macedonia, Greece. The experimental analysis was conducted over nine days during the summer. The operative temperature exceeded the acceptable limits for most days, while the same can be stated for the PMV, demonstrating high indoor air and radiant temperature values. The weaknesses of applying the above thermal comfort models in this type of buildings are also discussed. Relative humidity presents generally acceptable values during operation time, indicating the contribution of natural ventilation; nevertheless, as demonstrated by the CO2 concentration values, the ventilation rate can be further increased. On the basis of the above findings, a renovation scenario has been formulated, considering the installation of an air-conditioning system, as well as specific interventions, towards the improvement of the building envelope and systems’ thermal performance. A dynamic energy analysis, based on Energy Plus software, had energy savings of 9%, noting the considerable upgrade of indoor conditions. Overall, the proposed combined investigation approach proved to be suitable for such a complicated problem, as the one of indoor aquatic centers, presenting a high generalization potential.

14 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ioannis SakellarisIoannis Sakellaris
Ioannis Sakellaris
GPGiannis Papadopoulos
Giannis Papadopoulos
Dikaia SaragaDikaia Saraga
Dikaia Saraga
TXThalia Xenofontos
Thalia Xenofontos
Evangelos TolisEvangelos Tolis
Evangelos Tolis
JBJohn G. Bartzis
John G. Bartzis
This study investigated the indoor environment quality (IEQ) of eight office buildings of interest due to: (a) their location at the region of Western Macedonia, Greece, which is an area characterized by aggravated air quality and is currently in a transition phase because of changes in the energy production strategy to reduce the use of lignite as an energy fuel; and (b) the survey’s timing, characterized by new working conditions implemented during the COVID-19 pandemic period. In-site measurements were performed to identify the indoor air pollutants to which the occupants were exposed, while questionnaires were collected regarding the participants’ perception of the working environment conditions, indoor air quality, and health symptoms. The statistical analysis results showed that the most-reported health symptoms were headache, dry eyes, and sneezing. The acceptance of new working conditions showed a significant correlation with their overall comfort and health perception. Occupants in offices with higher pollutant concentrations, such as NO2, benzene and toluene, were more likely to report health symptoms. The evaluation of the plausible health risks for the occupants of the buildings with carcinogenic and no-cancer models showed that health problems could exist despite low pollutant concentration levels.