Andrea Pautasso

Dr. Andrea Pautasso

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2020 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Open access
PDF file
APAndrea Pautasso
Andrea Pautasso
MCMarcello Capella
Marcello Capella
LBLuca Barberis
Luca Barberis
LDLuca Drocco
Luca Drocco
RVRiccardo Giai Via
Riccardo Giai Via
LSLuigi Sabatini
Luigi Sabatini
Purpose: The aim of this study was to define the subjective and objective clinical results of all-inside surgical technique at a medium-term follow-up and to compare these results with those obtained from antero-medial (AM) ACL reconstruction technique using hamstrings (HS) or bone-patellar tendon-bone (BpTB) grafts to detect eventual superiority of one technique to another. Methods: A retrospective analysis of routinely collected data was conducted. Inclusion criteria were ACL reconstruction through all-inside technique or AM technique with HS or BpTB performed between January 2015 and May 2018; age between 15 and 30 year old; minimum 24 months’ available follow-up. Exclusion criteria were contralateral ACL reconstruction; need for any other associated procedures during surgery. Clinical outcomes were assessed with KOOS, Lysholm, Tegner scores and KT-1000 device. Results: According to the selection criteria, 157 patients were enrolled and divided subsequently into 3 groups: all-inside (51 patients), AM-HS (53 patients) and AM-BpTB (53 patients). A significant postoperative improvement of each score in all groups was detected. The mean KT-1000 was 3.1 ± 1.0 mm in all-inside group, while 3.3 ± 1.4 mm and 2.5 ± 0.4 mm in AM-HS and AM-BpTB groups, respectively. Comparing the results obtained, no statistically significant difference was found between the three techniques (p = 0.27). Statistically significant differences were highlighted in surgical duration: all-inside method was the longest (117′), followed by AM-BpTB surgery (101′) and AM-HS technique (87′). Conclusions: The all-inside technique showed good postoperative results at medium-term follow-up. It could be a valuable solution for ACL reconstruction, especially in young patients due to its less invasiveness, despite surgical skills and time needed. Levels of evidence: Level IV.

1 January 2021 in Foot and Ankle Surgery
Verified
Journal Article
Closed access
FBFederico Bertolo
Federico Bertolo
APAndrea Pautasso
Andrea Pautasso
CCClaudio Cuocolo
Claudio Cuocolo
DIDaniela Invernizzi
Daniela Invernizzi
FAFrancesco Atzori
Francesco Atzori

1 November 2021 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Open access
PDF file
APAndrea Pautasso
Andrea Pautasso
IZIlaria Zorzolo
Ilaria Zorzolo
Enrico BellatoEnrico Bellato
Enrico Bellato
PPPietro Pellegrino
Pietro Pellegrino
AFA. Ferrario
A. Ferrario
FCF. Castoldi
F. Castoldi
Purpose: Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. Methods: Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. Results: At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. Conclusions: Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. Levels of evidence: Level II.

10 July 2021 in MUSCULOSKELETAL SURGERY
Verified
Journal Article
Open access
PDF file
APAndrea Pautasso
Andrea Pautasso
LSLuigi Sabatini
Luigi Sabatini
MCM. Capella
M. Capella
FSF. Saccia
F. Saccia
LRLorenzo Rissolio
Lorenzo Rissolio
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Purpose: The aim of this study was to evaluate the clinical outcomes of patients treated with anatomic medial patellofemoral ligament (MPFL) reconstruction with and without tibial tuberosity osteotomy (TTO). Correlations between patient's age, gender, pre-injury physical activity and the achieved results were investigated as secondary endpoints. Methods: An observational retrospective study with prospective collected data was performed. Inclusion criteria were: treatment with anatomic MPFL reconstruction with gracilis tendon according to Schӧttle’s technique performed between 2011 and 2017; associated TTO as unique accessory procedure; skeletal joint maturity; a minimum follow-up of 12 months after surgery. Clinical outcomes were assessed with the Kujala, Lysholm and Tegner scores. Results: Forty patients (42 knees) were included, 64% of them underwent TTO. The Kujala score significantly improved from 47.4 ± 17.6 preoperatively to 89.4 ± 13.6 postoperatively (p < 0.01). The average Lysholm score was 45.6 ± 20.5 preoperatively: it showed a significant increase to 89.8 ± 12.8 postoperatively (p < 0.01). Pre-injury mean Tegner was 5.9 ± 1.8, while it dropped to 3.0 ± 1.6 after injury. After surgery, Tegner resulted 4.9 ± 1.6. Forty-three percent of patients regained the pre-injury sport activity level. Redislocation rate was 2.4%. Conclusion: Anatomic MPFL reconstruction allows excellent patellar stability recovery, knee functionality improvement, return to Activities of Daily Living and a low redislocation rate. Better results were achieved in younger (under 30 years old) and higher sports activity-level subjects. The TTO association provided clinical results comparable to isolated MPFL reconstructions, suggesting that the two procedures can be safely accomplished together without affecting the positive outcomes. Level of evidence: Level IV.

1 January 2021 in JBJS Case Connector
Verified
Journal Article
Closed access
LSLuigi Sabatini
Luigi Sabatini
GNGiulia Nicolaci
Giulia Nicolaci
MGMatteo Giachino
Matteo Giachino
SRSalvatore Risitano
Salvatore Risitano
APAndrea Pautasso
Andrea Pautasso
AMAlessandro Maria MASSE'
Alessandro Maria MASSE'
Case: A 19-year-old woman with persistent anterior knee pain was diagnosed with a complex tibial and femoral torsional deformity (26° of femoral anteversion and 49° of tibial external rotation). To achieve the correct realignment of the lower limb, rotational double osteotomies were needed. After planning the correction on the computed tomography scan and three-dimensional (3D) model, a custom-made 3D-printed guiding system was produced to support the surgery. Conclusion: The 3D-printed planning model and the surgical guiding system are crucial elements to achieve optimal results for complex malalignment cases. The “tailored” guides led to a perfect match between the planned correction and the intraoperative result.

1 October 2023 in Annals of Joint
Verified
Journal Article
Open access
PDF file
APAndrea Pautasso
Andrea Pautasso
GBGiuseppe Bardellini
Giuseppe Bardellini
PSPlacido Stissi
Placido Stissi
FDFabio D'Angelo
Fabio D'Angelo
Background and Objective: Modular neck adapters allow different length and offset changes to reach a stable total hip arthroplasty (THA) and permit a quick partial hip revision procedure without removing the existing components. The literature is poor on this matter and about the long-term related outcomes. This narrative review summarizes the most recent literature about these devices as an option of surgical treatment in partial total hip arthroplasty revision (THAr) focusing on indications, clinical and radiological outcomes, and related complications. Methods: The narrative review of the current available literature was conducted in December 2022 through electronic database. The terms used were: “Head neck taper” OR “Merete BioBall” AND “revision Total Hip Arthroplasty (MeSH Terms)”. The timeframe was limited between 01/01/2000 and 01/12/2022. The studies regarding the clinical use of the Merete BioBall® system in hip revision surgery were included, while all the papers concerning modular stem prosthesis were excluded. Key Content and Findings: The surgical procedure is safe, quick and allows the surgeon to correct a well-fixed stem version, length and offset, besides retensioning soft tissues. Clinical and radiological outcomes are good with low complications rates. Conclusions: The modular neck adapter system seems to be a good surgical procedure for recurrent dislocation of THA, especially in case of a second THAr surgery. However, the main indication of adapter use remains the isolated acetabular cup revision. The related complications are rare: the worst is the re-dislocation due to an insufficient stem version and length correction. Re-dislocation rates reported in literature vary from 5.2% to 15%. Corrosion or fretting of the modular system are not reported in literature.