Jorge Aramburu

Dr. Jorge Aramburu

Universidad de Navarra, TECNUN Escuela de Ingeniería
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2020 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Open access
JHJorge Mariscal Harana
Jorge Mariscal Harana
Peter CharltonPeter Charlton
Peter Charlton
SVSamuel Vennin
Samuel Vennin
Jorge AramburuJorge Aramburu
Jorge Aramburu
MFMateusz Cezary Florkow
Mateusz Cezary Florkow
JAJordi Alastruey
Jordi Alastruey
First, our proposed methods for CV parameter estimation and a comprehensive set of methods from the literature were tested using in silico and clinical datasets. Second, optimized algorithms for estimating cBP from aortic flow were developed and tested for a wide range of cBP morphologies, including catheter cBP data. Third, a dataset of simulated cBP waves was created using a three-element Windkessel model. Fourth, the Windkessel model dataset and optimized algorithms are freely available.

13 September 2021 in CardioVascular and Interventional Radiology
Verified
Journal Article
Open access
PDF file
Jorge AramburuJorge Aramburu
Jorge Aramburu
RARaúl Antón
Raúl Antón
MRMacarena Rodríguez-Fraile
Macarena Rodríguez-Fraile
BSBruno Sangro
Bruno Sangro
JBJosé Ignacio Bilbao
José Ignacio Bilbao
Yttrium-90 radioembolization (RE) is a widely used transcatheter intraarterial therapy for patients with unresectable liver cancer. In the last decade, computer simulations of hepatic artery hemodynamics during RE have been performed with the aim of better understanding and improving the therapy. In this review, we introduce the concept of computational fluid dynamics (CFD) modeling with a clinical perspective and we review the CFD models used to study RE from the fluid mechanics point of view. Finally, we show what CFD simulations have taught us about the hemodynamics during RE, the current capabilities of CFD simulations of RE, and we suggest some future perspectives.


31 March 2016 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Jorge AramburuJorge Aramburu
Jorge Aramburu
RARaúl Antón
Raúl Antón
ARAlejandro Rivas
Alejandro Rivas
Juan Carlos RamosJuan Carlos Ramos
Juan Carlos Ramos
BSBruno Sangro
Bruno Sangro
JBJosé Ignacio Bilbao
José Ignacio Bilbao

27 July 2017 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Jorge AramburuJorge Aramburu
Jorge Aramburu
RARaúl Antón
Raúl Antón
ARAlejandro Rivas
Alejandro Rivas
Juan Carlos RamosJuan Carlos Ramos
Juan Carlos Ramos
BSBruno Sangro
Bruno Sangro
JBJosé Ignacio Bilbao
José Ignacio Bilbao

16 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RARaúl Antón
Raúl Antón
JAJavier Antoñana
Javier Antoñana
Jorge AramburuJorge Aramburu
Jorge Aramburu
AEAna Ezponda
Ana Ezponda
EPElena Prieto
Elena Prieto
MRMacarena Rodríguez-Fraile
Macarena Rodríguez-Fraile
Radioembolization (RE) with yttrium-90 (90Y) microspheres, a transcatheter intraarterial therapy for patients with liver cancer, can be modeled computationally. The purpose of this work was to correlate the results obtained with this methodology using in vivo data, so that this computational tool could be used for the optimization of the RE procedure. The hepatic artery three-dimensional (3D) hemodynamics and microsphere distribution during RE were modeled for six 90Y-loaded microsphere infusions in three patients with hepatocellular carcinoma using a commercially available computational fluid dynamics (CFD) software package. The model was built based on in vivo data acquired during the pretreatment stage. The results of the simulations were compared with the in vivo distribution assessed by 90Y PET/CT. Specifically, the microsphere distribution predicted was compared with the actual 90Y activity per liver segment with a commercially available 3D-voxel dosimetry software (PLANET Dose, DOSIsoft). The average difference between the CFD-based and the PET/CT-based activity distribution was 2.36 percentage points for Patient 1, 3.51 percentage points for Patient 2 and 2.02 percentage points for Patient 3. These results suggest that CFD simulations may help to predict 90Y-microsphere distribution after RE and could be used to optimize the RE procedure on a patient-specific basis.