19 January 2022 in Journal of Magnetic Resonance Imaging
Magnetic resonance imaging (MRI) is increasingly utilized as a radiation‐free alternative to computed tomography (CT) for the diagnosis and treatment planning of musculoskeletal pathologies. MR imaging of hard tissues such as cortical bone remains challenging due to their low proton density and short transverse relaxation times, rendering bone tissues as nonspecific low signal structures on MR images obtained from most sequences. Developments in MR image acquisition and post‐processing have opened the path for enhanced MR‐based bone visualization aiming to provide a CT‐like contrast and, as such, ease clinical interpretation. The purpose of this review is to provide an overview of studies comparing MR and CT imaging for diagnostic and treatment planning purposes in orthopedic care, with a special focus on selective bone visualization, bone segmentation, and three‐dimensional (3D) modeling. This review discusses conventional gradient‐echo derived techniques as well as dedicated short echo time acquisition techniques and post‐processing techniques, including the generation of synthetic CT, in the context of 3D and specific bone visualization. Based on the reviewed literature, it may be concluded that the recent developments in MRI‐based bone visualization are promising. MRI alone provides valuable information on both bone and soft tissues for a broad range of applications including diagnostics, 3D modeling, and treatment planning in multiple anatomical regions, including the skull, spine, shoulder, pelvis, and long bones.Level of Evidence: 3Technical Efficacy: Stage 3
8 October 2019 in Magnetic Resonance in Medicine
CBCornelis A. T. van Den Berg
Cornelis A. T. van Den Berg
+5
Purpose: To study the influence of gradient echo–based contrasts as input channels to a 3D patch‐based neural network trained for synthetic CT (sCT) generation in canine and human populations.Methods: Magnetic resonance images and CT scans of human and canine pelvic regions were acquired and paired using nonrigid registration. Magnitude MR images and Dixon reconstructed water, fat, in‐phase and opposed‐phase images were obtained from a single T1‐weighted multi‐echo gradient‐echo acquisition. From this set, 6 input configurations were defined, each containing 1 to 4 MR images regarded as input channels. For each configuration, a UNet‐derived deep learning model was trained for synthetic CT generation. Reconstructed Hounsfield unit maps were evaluated with peak SNR, mean absolute error, and mean error. Dice similarity coefficient and surface distance maps assessed the geometric fidelity of bones. Repeatability was estimated by replicating the training up to 10 times.Results: Seventeen canines and 23 human subjects were included in the study. Performance and repeatability of single‐channel models were dependent on the TE‐related water–fat interference with variations of up to 17% in mean absolute error, and variations of up to 28% specifically in bones. Repeatability, Dice similarity coefficient, and mean absolute error were statistically significantly better in multichannel models with mean absolute error ranging from 33 to 40 Hounsfield units in humans and from 35 to 47 Hounsfield units in canines.Conclusion: Significant differences in performance and robustness of deep learning models for synthetic CT generation were observed depending on the input. In‐phase images outperformed opposed‐phase images, and Dixon reconstructed multichannel inputs outperformed single‐channel inputs.
1 December 2020 in Radiotherapy and Oncology
To assess the feasibility of magnetic resonance imaging (MRI)-only treatment planning for photon and proton radiotherapy in children with abdominal tumours. The study was conducted on 66 paediatric patients with Wilms' tumour or neuroblastoma (age 4 ± 2 years) who underwent MR and computed tomography (CT) acquisition on the same day as part of the clinical protocol. MRI intensities were converted to CT Hounsfield units (HU) by means of a UNet-like neural network trained to generate synthetic CT (sCT) from T1- and T2-weighted MR images. The CT-to-sCT image similarity was evaluated by computing the mean error (ME), mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and Dice similarity coefficient (DSC). Synthetic CT dosimetric accuracy was verified against CT-based dose distributions for volumetric-modulated arc therapy (VMAT) and intensity-modulated pencil-beam scanning (PBS). Relative dose differences (Ddiff) in the internal target volume and organs-at-risk were computed and a three-dimensional gamma analysis (2 mm, 2%) was performed. The average ± standard deviation ME was -5 ± 12 HU, MAE was 57 ± 12 HU, PSNR was 30.3 ± 1.6 dB and DSC was 76 ± 8% for bones and 92 ± 9% for lungs. Average Ddiff were 99% (range [85; 100]%) for VMAT and >96% (range [87; 100]%) for PBS. The deep learning-based model generated accurate sCT from planning T1w- and T2w-MR images. Most dosimetric differences were within clinically acceptable criteria for photon and proton radiotherapy, demonstrating the feasibility of an MRI-only workflow for paediatric patients with abdominal tumours.
30 June 2021 in Journal of Orthopaedic Research
This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three‐dimensional radiofrequency‐spoiled T1‐weighted multi‐echo gradient‐echo MR images using a commercially available deep learning‐enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center‐edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center‐to‐midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in‐training on CT and sCT images. The reliability and agreement of CT‐ and sCT‐based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland–Altman plots, and two one‐sided tests for equivalence. The surface distance between CT‐ and sCT‐based bone models were on average submillimeter. CT‐ and sCT‐based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology.
16 October 2020 in American Journal of Physiology-Heart and Circulatory Physiology
First, our proposed methods for CV parameter estimation and a comprehensive set of methods from the literature were tested using in silico and clinical datasets. Second, optimized algorithms for estimating cBP from aortic flow were developed and tested for a wide range of cBP morphologies, including catheter cBP data. Third, a dataset of simulated cBP waves was created using a three-element Windkessel model. Fourth, the Windkessel model dataset and optimized algorithms are freely available.
30 October 2023 in Journal of Orthopaedic Research
This study aims at assessing approaches for generating high‐resolution magnetic resonance imaging‐ (MRI‐) based synthetic computed tomography (sCT) images suitable for orthopedic care using a deep learning model trained on low‐resolution computed tomography (CT) data. To that end, paired MRI and CT data of three anatomical regions were used: high‐resolution knee and ankle data, and low‐resolution hip data. Four experiments were conducted to investigate the impact of low‐resolution training CT data on sCT generation and to find ways to train models on low‐resolution data while providing high‐resolution sCT images. Experiments included resampling of the training data or augmentation of the low‐resolution data with high‐resolution data. Training sCT generation models using low‐resolution CT data resulted in blurry sCT images. By resampling the MRI/CT pairs before the training, models generated sharper images, presumably through an increase in the MRI/CT mutual information. Alternatively, augmenting the low‐resolution with high‐resolution data improved sCT in terms of mean absolute error proportionally to the amount of high‐resolution data. Overall, the morphological accuracy was satisfactory as assessed by an average intermodal distance between joint centers ranging from 0.7 to 1.2 mm and by an average intermodal root‐mean‐squared distances between bone surfaces under 0.7 mm. Average dice scores ranged from 79.8% to 87.3% for bony structures. To conclude, this paper proposed approaches to generate high‐resolution sCT suitable for orthopedic care using low‐resolution data. This can generalize the use of sCT for imaging the musculoskeletal system, paving the way for an MR‐only imaging with simplified logistics and no ionizing radiation.