Huyen Tran Tran

Ms. Huyen Tran Tran


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2025 in Batteries
Verified
Journal Article
Open access
PDF file
IAIntizar Abbas
Intizar Abbas
HTHuyen Tran Tran
Huyen Tran Tran
TTTran Thi Ngoc Tran
Tran Thi Ngoc Tran
TPThuy Linh Pham
Thuy Linh Pham
ESEui-Chol Shin
Eui-Chol Shin
Jong-Sook LeeJong-Sook Lee
Jong-Sook Lee
Conventional applications of the Galvanostatic Intermittent Titration Technique (GITT) and EIS for estimating chemical diffusivity in battery electrodes face issues such as insufficient relaxation time to reach equilibrium, excessively long pulse durations that violate the short-time diffusion assumption, and the assumption of sequential electrode reaction and diffusion processes. In this work, a quasi-equilibrium criterion of 0.1 mV h−1 was applied to NMC622 electrodes, yielding 8–9 h relaxations below 3.8 V, but above 3.8 V, voltage decayed linearly and indefinitely, even upon discharging titration, showing unusual nonmonotonic relaxation behavior. The initial 36-s transients of a 10-min galvanostatic pulse and diffusion impedance in series with the electrode reaction yielded consistent diffusivity values. However, solid-state diffusion in spherical active particles within porous electrodes, where ambipolar diffusion occurs in the pore electrolyte with t+=0.3, requires a physics-based three-rail transmission line model (TLM). The corrected diffusivity may be three to four times higher. An analytic two-rail TLM approximating the three-rail numerical model was applied to temperature- and frequency-dependent EIS data. This approach mitigates parameter ambiguity and unphysical correlations in EIS. Physics-based EIS enables the identification of multistep energetics and the diagnosis of performance and degradation mechanisms.

30 May 2024 in Inorganics
Verified
Journal Article
Open access
PDF file
TDTrung Doan
Trung Doan
John G. FisherJohn G. Fisher
John G. Fisher
Jong-Sook LeeJong-Sook Lee
Jong-Sook Lee
HTHuyen Tran Tran
Huyen Tran Tran
JGJie Gao
Jie Gao
JKJae-Hyeon Ko
Jae-Hyeon Ko
KNbO3 single crystals are grown by the self-flux method using K2CO3 as a flux, but often suffer from discolouration. In this work, KNbO3 single crystals were grown by the flux method using KBO2 as a flux. KNbO3 powder was prepared by the solid-state reaction of K2CO3 and Nb2O5. KBO2 was fabricated by the reaction of K2B4O7·4H2O and K2CO3. Single crystals of KNbO3 were grown in a Pt crucible and the structure and dielectric properties of the single crystals were investigated. X-ray diffraction showed the KNbO3 single crystals to have an orthorhombic Cmm2 perovskite unit cell at room temperature. The existence of ferroelastic domains was revealed by transmission electron microscopy. Electron probe microanalysis showed the single crystals to be stoichiometric and contain small amounts of B. Differential thermal analysis, Raman scattering and impedance spectroscopy were used to study the phase transitions. KBO2 may be a suitable flux for the growth of KNbO3 single crystals.

5 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
IAIntizar Abbas
Intizar Abbas
HTHuyen Tran Tran
Huyen Tran Tran
TTThi Ngoc Tran Tran
Thi Ngoc Tran Tran
TPThuy Linh Pham
Thuy Linh Pham
ESEui-Chol Shin
Eui-Chol Shin
Jong-Sook LeeJong-Sook Lee
Jong-Sook Lee
The galvanostatic intermittent titration technique (GITT) was applied to NMC622 positive electrodes, with Electrochemical Impedance Spectroscopy (EIS) performed at quasi-equilibrium conditions determined by cutoff criteria based on relaxation rates. Below an open-circuit voltage (OCV) of 3.8 V, the cutoff criterion of 0.1 mV h−1 was reached after approximately 8 hours. However, above 3.8 V, a non-saturating voltage decay was observed, increasing up to ∼0.56 mV h−1 above 4.1 V during charging steps. This persistent voltage decay upon subsequent discharging steps led to non-monotonic relaxation behavior. A pulse time of 10 minutes did not satisfy the t dependence required for GITT kinetic analysis. Instead, the initial 36-second transients were extended for chemical diffusivity evaluation, aligning with the Warburg-like response observed in EIS, consistent with the sequential reaction-diffusion assumption. GITT analysis for solid-state diffusivity is ineffective for spherical active particles dispersed in porous electrodes and performs even worse due to liquid-phase diffusion within the pores, where t+=0.3. The apparent SOC-independent chemical diffusivity obtained from GITT across both low and high OCV ranges suggests that the process is dominated by liquid-phase diffusion. The application of the physics-based three-rail transmission line model (TLM) developed by Gaberšček et al. in EIS holds practical potential for deconvoluting the two diffusion kinetics.

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
JLJong-Sook Lee
Jong-Sook Lee
HTHuyen Tran Tran
Huyen Tran Tran
CPChanwoo Park
Chanwoo Park
TPThuy Linh Pham
Thuy Linh Pham
ESEui-Chol Shin
Eui-Chol Shin
JYJi Haeng Yu
Ji Haeng Yu
Despite its indispensability, EIS has been ineffective in solid oxide cell characterizations. DRT, equivalent to (RQ) series modeling, is becoming popular, and the long-time frustrated community appears to give up the equivalent circuit parameter estimation. Percolating ionic-electronic networks, (surface/bulk) diffusion-reaction kinetics, and gas transport can be represented by the resistors and capacitors in the transmission line models. We had suggested a transmission line modeling of Ni-YSZ/LSM solid oxide cells [1, 2, 3], which now looks defective in several points. The responses of the percolating network and the diffusion-reaction kinetics were confounded in a single transmission line model. Side-by-side parallel electrode-reaction and gas-supply were artificially separated and connected in series. The impedance of the Ni-YSZ electrode appears to have been underestimated. Recent multiphysics simulations matching experimental results [4] provide valuable insight into these mechanisms. Equivalent circuit modeling, preferably analytical, provides the parameters of the transmission line models that can have a practical impact on the usefulness of EIS. Fig. 1 shows the combined model based on physics, partly empirically, for solid oxide cells. To deconvolute the components of the ionic-electronic rail, R ion and R eon , and the diffusion-reaction controlled mechanism in solid oxide cells, which should be distinguished from the Butler-Volmer mechanism in liquid electrochemistry [5, 6], a proper diffusion-reaction impedance should be put into the distributed shunt admittance, in parameters R d , C d , and R rxn . The model may vary with specific mechanisms such as diffusion-reaction in parallel or diffusion and local boundary reaction (spill-over). Surface or bulk diffusion may be differentiated by the diffusion geometry or by the magnitude of the parameters. Because the local gas concentration determines the activity driving the diffusion and reaction, gas transport needs to be spatially synchronized with electrode reaction represented by the transmission line with ionic and electronic rails. As the phenomena and the impedance behavior are similar to the salt concentration impedance in battery electrodes, an empirical three-rail transmission line model [7, 8, 9] is suggested. The ionic rail for reactive gas is connected to the unreactive gas transport rail R gas , comparable to the active and inert ions in the binary electrolyte model [10]. The C gas explains the gas concentration impedance. The gas conversion reaction for planar gas flow can be described by R conv C conv series circuit to C gas . If observable, additional effects like current-collecting layers, buffer layers, electronic leakage in the electrolytes, etc. can be added. The circuit model needs to be supported by the multiphysics simulation as [4]. The three-rail model requires the numerical calculation [10, 11, 12], which is not easy to apply to fitting the experimental data. An approximated two-rail model, which is analytical [13], has been recently developed [9,14], which can be powerfully employed for the least-squares fitting of the experimental data. The middle and bottom-rail parameters were combined into one-rail and the analytic two-rail model was applied to the EIS of Ni-YSZ supported button cell of 0.28 cm 2 LSM air electrode, reported previously [1,2], Fig. 2(a). Unlike the previous analysis, the distributed (surface) diffusion-reaction parameters of the Ni-YSZ (left) and LSM-YSZ (right) electrodes, R d L , R d R , R rxn L , R rxn R , are separated from the ionic rail resistance, R ion L , R ion R . The R ion L represents the overall ionic resistance through the cell, including gas-concentration impedance. The response of electrode-reaction and gas-concentration impedance of Ni-YSZ electrodes are at high and low frequencies, respectively, with LSM-YSZ electrode reaction in the middle-frequency range, as previously analyzed, but the parameters are more physically interrelated according to the model, Fig. 1, and the parameters are expected more accurate. Fig. 2(b) shows the EIS of Ni-YSZ supported cell with LSCF air electrode of 100 cm 2 area in a 10-cell stack under electrolysis for 1028 h. The well-separated circular low-frequency impedance is the gas conversion impedance, characteristic of the planar gas flow in stacks. It is described by R conv L - C conv L series circuit to C gas L . The inductive loop behavior indicated at the transition to the gas conversion impedance can be described by an inductor in series to R gas L , as for the battery impedance model [9]. The strong high-frequency inductance effect can be described by a constant phase element as Z ind = ( jω ) α L wire in parallel to R str , in contrast to L wire - R str model [1, 2] used in Fig. 2(a). The parameters not given are either unused since the response is not shown in the experimental data, or fitted negligibly small. The presented numerical simulations of the 3-rail model are based on the fit results using the approximate analytical model, which agrees more or less satisfactorily. Poor agreement between the two results indicates the improperness of the parameters. The fit results should be justified by the systematic and physics-based behavior with the experimental variables, not only by the fit quality. The behaviors of the circuit parameters with humidity, oxygen partial pressure, gas flow rates, current in fuel cell/electrolysis modes, and degradation will be presented. Shin E C, Ahn P A, Seo H H, Jo J M, Kim S D, Woo S K, Yu J H, Mizusaki J and Lee J S 2013 Solid State Ionics 232 80–96 Shin E C, Ahn P A, Seo H H, Nguyen D T, Kim S D, Woo S K, Yu J H and Lee J S 2015 Solid State Ionics 277 1–10 Shin E C, Ma J, Ahn P A, Seo H H, Nguyen D T and Lee J S 2016 Electrochim. Acta 188 240–253 Taubmann J, Sun X, Rizvandi O B and Frandsen H L 2023 Journal of Power Sources 588 233739 Mizusaki J, Amano K, Yamauchi S and Fueki K 1987 Solid State Ionics 22 313–322 Mizusaki J 2014 Electrochemistry 82 819–829 Gaberscek M 2021 Nat. Commun. 12 6513 Abbas I, Tran H T, Tran T N T, Pham T L, Shin E C, Park C W, Yu S B, Lee O J, Nguyen A G, Cho H H et al. 2025, submitted Park C W 2025 Ph.D. Thesis Chonnam National University Moskon J, Zuntar J, Talian S D, Dominko R and Gaberscek M 2020 J. Electrochem. Soc. 167 140539 Moskon J and Gaberscek M 2021 J. Power Sources Adv. 7 100047 Firm M, Moskon J, Kapun G, Talian S D, Kamsek A R, Stefancic M, Hocevar S, Dominko R and Gaberscek M 2024 J. Electrochem. Soc. 171 120543 Drvaric Talian S, Bobnar J, Sinigoj A R, Humar I and Gaberscek M 2019 J. Phys. Chem. C 123 27997–28007 Shin E C, Ryu J H, Ka B H, Lee J S, Jeong D H and Ho K 2025 Patent Application No. 10-2025-0001795, South Korea Figure 1 Figure 2