Guoguang Rong

Prof. Dr. Guoguang Rong

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Guoguang RongGuoguang Rong
Guoguang Rong
YZYuqiao Zheng
Yuqiao Zheng
Mohamad SawanMohamad Sawan
Mohamad Sawan
Wearable sensors have gained popularity over the years since they offer constant and real-time physiological information about the human body. Wearable sensors have been applied in a variety of ways in clinical settings to monitor health conditions. These technologies require energy sources to carry out their projected functionalities. In this paper, we review the main energy sources used to power wearable sensors. These energy sources include batteries, solar cells, biofuel cells, supercapacitors, thermoelectric generators, piezoelectric and triboelectric generators, and radio frequency (RF) energy harvesters. Additionally, we discuss wireless power transfer and some hybrids of the above technologies. The advantages and drawbacks of each technology are considered along with the system components and attributes that make these devices function effectively. The objective of this review is to inform researchers about the latest developments in this field and present future research opportunities.

28 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
Zina FredjZina Fredj
Zina Fredj
Guoguang RongGuoguang Rong
Guoguang Rong
Mohamad SawanMohamad Sawan
Mohamad Sawan
Enzymatic biofuel cells (EBFCs) have emerged as a transformative solution in the quest for sustainable energy, offering a biocatalyst-driven alternative for powering wearable and implantable self-powered biosensors. These systems harness renewable enzyme activity under mild conditions, positioning them as ideal candidates for next-generation biosensing applications. Despite their promise, their practical deployment is limited by challenges such as low power density, restricted operational lifespan, and miniaturization complexities. This review provides an in-depth exploration of the evolving landscape of EBFC technology, beginning with fundamental principles and the latest developments in electron transfer mechanisms. A critical assessment of enzyme immobilization techniques, including physical adsorption, covalent binding, entrapment, and cross-linking, underscores the importance of optimizing enzyme stability and catalytic activity for enhanced bioelectrode performance. Additionally, we examine advanced bioelectrode materials, focusing on the role of nanostructures such as carbon-based nanomaterials, noble metals, conducting polymers, and metal–organic frameworks in improving electron transfer and boosting biosensor efficiency. Also, this review includes case studies of EBFCs in wearable self-powered biosensors, with particular attention to the real-time monitoring of neurotransmitters, glucose, lactate, and ethanol through sweat analysis, as well as their integration into implantable devices for continuous healthcare monitoring. Moreover, a dedicated discussion on challenges and trends highlights key limitations, including durability, power management, and scalability, while presenting innovative approaches to address these barriers. By addressing both technical and biological constraints, EBFCs hold the potential to revolutionize biomedical diagnostics and environmental monitoring, paving the way for highly efficient, autonomous biosensing platforms.

28 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
YZYuqiao Zheng
Yuqiao Zheng
SBSumin BIAN
Sumin BIAN
JSJiacheng Sun
Jiacheng Sun
LWLiaoyong Wen
Liaoyong Wen
Guoguang RongGuoguang Rong
Guoguang Rong
Mohamad SawanMohamad Sawan
Mohamad Sawan
Cost-effective, rapid, and sensitive detection of SARS-CoV-2, in high-throughput, is crucial in controlling the COVID-19 epidemic. In this study, we proposed a vertical microcavity and localized surface plasmon resonance hybrid biosensor for SARS-CoV-2 detection in artificial saliva and assessed its efficacy. The proposed biosensor monitors the valley shifts in the reflectance spectrum, as induced by changes in the refractive index within the proximity of the sensor surface. A low-cost and fast method was developed to form nanoporous gold (NPG) with different surface morphologies on the vertical microcavity wafer, followed by immobilization with the SARS-CoV-2 antibody for capturing the virus. Modeling and simulation were conducted to optimize the microcavity structure and the NPG parameters. Simulation results revealed that NPG-deposited sensors performed better in resonance quality and in sensitivity compared to gold-deposited and pure microcavity sensors. The experiment confirmed the effect of NPG surface morphology on the biosensor sensitivity as demonstrated by simulation. Pre-clinical validation revealed that 40% porosity led to the highest sensitivity for SARS-CoV-2 pseudovirus at 319 copies/mL in artificial saliva. The proposed automatic biosensing system delivered the results of 100 samples within 30 min, demonstrating its potential for on-site coronavirus detection with sufficient sensitivity.

23 September 2021 in Advanced Materials Technologies
Verified
Journal Article
Open access
PDF file
YSYi Su
Yi Su
NLNing Li
Ning Li
LWLang Wang
Lang Wang
RLRui Lin
Rui Lin
YZYuqiao Zheng
Yuqiao Zheng
Mohamad SawanMohamad Sawan
Mohamad Sawan
Recent advances in wearable bioelectronics have driven various healthcare applications, such as the monitoring, sensing, and treating of various diseases. However, unsustainable batteries and toxic power solutions hinder their use at the skin interface or in vivo. As a promising power solution, supercapacitors have attracted the attention of researchers. However, there are still several drawbacks, such as the transparency, stretchability, biocompatibility, and flexibility of these materials, when these energy reservoirs are used as power supplies for skin‐interfaced electronics. In this work, a novel microfabrication approach for fabricating supercapacitors using anodic aluminum oxide templates is presented. In this work, a large capacitance value of 15.02 mF cm−2, as well as good transparency, stretchability, and biocompatibility are obtained. Thus, it is verified that the proposed supercapacitors are suitable as skin‐interfaced power solutions.

31 August 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Guoguang RongGuoguang Rong
Guoguang Rong
Yankun XuYankun Xu
Yankun Xu
Mohamad SawanMohamad Sawan
Mohamad Sawan
We describe a machine learning (ML) approach to processing the signals collected from a COVID-19 optical-based detector. Multilayer perceptron (MLP) and support vector machine (SVM) were used to process both the raw data and the feature engineering data, and high performance for the qualitative detection of the SARS-CoV-2 virus with concentration down to 1 TCID50/mL was achieved. Valid detection experiments contained 486 negative and 108 positive samples, and control experiments, in which biosensors without antibody functionalization were used to detect SARS-CoV-2, contained 36 negative samples and 732 positive samples. The data distribution patterns of the valid and control detection dataset, based on T-distributed stochastic neighbor embedding (t-SNE), were used to study the distinguishability between positive and negative samples and explain the ML prediction performance. This work demonstrates that ML can be a generalized effective approach to process the signals and the datasets of biosensors dependent on resonant modes as biosensing mechanism.

11 December 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Guoguang RongGuoguang Rong
Guoguang Rong
Mohamad SawanMohamad Sawan
Mohamad Sawan
Tamm Plasmon Polariton (TPP) is a nanophotonic phenomenon that has attracted much attention due to its spatial strong field confinement, ease of mode excitation, and polarization independence. TPP has applications in sensing, storage, lasing, perfect absorber, solar cell, nonlinear optics, and many others. In this work, we demonstrate a biosensing platform based on TPP resonant mode. Both theoretical analyses based on the transfer matrix method and experimental validation through nonspecific detection of liquids of different refractive indices and specific detection of SARS-CoV-2 nucleocapsid protein (N-protein) are presented. Results show that the TPP biosensor has high sensitivity and good specificity. For N-protein detection, the sensitivity can be up to 1.5 nm/(µg/mL), and the limit of detection can reach down to 7 ng/mL with a spectrometer of 0.01 nm resolution in wavelength shift. Both nonspecific detection of R.I. liquids and specific detection of N-protein have been simulated and compared with experimental results to demonstrate consistency. This work paves the way for design, optimization, fabrication, characterization, and performance analysis of TPP based biosensors.