Jaimis Sajid Leon Colqui

Dr. Jaimis Sajid Leon Colqui

Universidade Estadual de Campinas, Campinas, São Paulo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
Rodolfo Antônio Ribeiro de MouraRodolfo Antônio Ribeiro de Moura
Rodolfo Antônio Ribeiro de Moura
Marco Aurélio Oliveira SchroederMarco Aurélio Oliveira Schroeder
Marco Aurélio Oliveira Schroeder
JFJosé Pissolato Filho
José Pissolato Filho
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
In most of the work that investigates the backflashover phenomenon due to direct lightning strikes, using EMT-type simulators, transmission lines are represented by the J. Marti model and the ground effect is computed employing J. R. Carson’s formulations. Thus, the ground displacement current is neglected, the line voltage definition corresponds to the wire potential formulation, and soil resistivity is considered frequency-independent. These considerations can lead to erroneous measurements of the occurrences of the backflashover phenomenon in the insulator strings of transmission line. In this sense, this paper presents a systematic sensitivity analysis study of lightning overvoltage in insulator strings considering more physically consistent models of the transmission line, which consider the displacement current, ground admittance correction, rigorous voltage definition, and frequency-dependent soil parameters. According to the results, for the case study, transmission line parameters modeling can present a maximum percentual difference of around 71.54%, considering the frequency range of first strokes. This difference leads to a percent difference of around 5.25% in the maximum overvoltage across the insulator strings. These differences confirm that the occurrence or not of backflashover in the insulator strings, including the disruption time, are sensitive to the line model considered.

25 August 2022 in IEEE Access
Verified
Journal Article
Open access
PBP. Juan Robles Balestero
P. Juan Robles Balestero
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
This work presents a transmission line model for simulating electromagnetic transients directly in the time domain. For this purpose, the exact equivalent $\pi $ -circuit is used, which represents the line taking into account its distributed and frequency-dependent parameters. The admittances that constitute the exact equivalent $\pi $ -circuit are approximated by rational functions using the vector fitting technique. Then, for each admittance, an electrical circuit is synthesized, consisting of an association of discrete elements (resistors, inductors, and capacitors) aiming at modeling the transmission line, thus allowing its use in any circuit simulation software and the eventual connection of nonlinear elements. From the simulation results, it is reasonable to state that the proposed model is a feasible representation, which aggregates the same features of the exact equivalent $\pi $ -circuit directly in the time domain, not only in steady state, but mainly during transients and also without the need for using convolutions, as well as inverse Laplace or Fourier transforms.

29 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
JAJesus Enrique Guevara Asorza
Jesus Enrique Guevara Asorza
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
JFJosé Pissolato Filho
José Pissolato Filho
This paper quantifies and discusses the increase in induced voltage on a sheath due to changes in duct banks in terms of type and dimensions along an underground transmission line, guaranteeing the ampacity required for a project. The four most common duct banks in double-circuit underground transmission lines with phase transposition were considered in this study, along with two special cross-bonding techniques: continuous cross-bonding (CCB) and sectionalized cross-bonding (SCB). These techniques aim to reduce sheath currents and enhance the distribution of the induced voltage on the sheath. The analysis considers two distinct scenarios in which the profile of the induced voltage is calculated: the first one accounts for underground obstructions, intersections with important traffic avenues, and ground with high excavation costs that force changes in the duct bank dimensions and configuration, which is the most exact and realistic case. The second one solely considers one typical configuration of a duct bank along the route. This last scenario is normally applied to calculate the induced voltage when an underground transmission design is required. The results show that when installing cables at a greater depth, it is imperative to increase the distance between them to guarantee the ampacity. The induced voltage on the sheath will rise as the distance increases. Furthermore, the results reveal that instead of calculating the induced voltage by considering the scenario that is exact and most like a real case, it is enough to calculate following the second scenario and then add a scaling factor according to each duct bank configuration.

27 January 2022 in IEEE Access
Verified
Journal Article
Open access
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
LELuis Carlos Timana Eraso
Luis Carlos Timana Eraso
PCPablo Torrez Caballero
Pablo Torrez Caballero
JFJose Pissolato Filho
Jose Pissolato Filho
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
Electromagnetic Transients Program make extensive use of transmission line models for the simulation of electromagnetic transients. This paper proposes a circuit representation of the modal transformation, more specifically Clarke’s matrix. The arrangement of ideal transformers we propose allows modal transformation to be directly implemented in software such as Alternative Transient Program - Electromagnetic Transients Program. We combined the proposed circuit with single-phase transmission line models that consider frequency independent and frequency dependent parameters to represent transposed three-phase transmission lines. The main advantage of the proposed approach is that it allows the implementation of new transmission line models without depending on models provided in applications. To show this capability, we included the frequency dependence of soil parameters in the simulations. Results show that the proposed model is accurate both in the frequency domain and in the time domain.

12 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
Anderson Ricardo Justo de AraújoAnderson Ricardo Justo de Araújo
Anderson Ricardo Justo de Araújo
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
JFJosé Pissolato Filho
José Pissolato Filho
The Lumped Parameter Model (LPM) is a known approach to represent overhead transmission lines (TLs), especially when these elements comprehend a few tens of kilometers. LPMs employ a large number of cascaded π-circuits to compute accurately the transient responses. These responses contain numerical spurious oscillations (NSO) characterized by erroneous peaks which distort the transient responses, mainly their peak values. Two modified LPM topologies composed of damping resistances inserted along the longitudinal or transversal branches of the cascaded π-circuits offer significant mitigations in the NSO. In this paper, in an effort to have the maximum mitigation of the NSO and low distortion in the transient responses, two modified topologies with optimized damping resistances are proposed to represent short TLs. Results demonstrate expressive attenuation in the peaks of NSO which reflect good agreement in comparison with the responses computed by the Bergeron’s line model. The mitigation of the NSO is carried out directly in the time domain and it does not require either analog or digital filters.Furthermore, no frequency-to-time transformations are necessary in this procedure. These alternative topologies can be incorporated into any electromagnetic transient program to study switching operations in power systems.

24 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
TPTainá Fernanda Garbelim Pascoalato
Tainá Fernanda Garbelim Pascoalato
Anderson Ricardo Justo de AraújoAnderson Ricardo Justo de Araújo
Anderson Ricardo Justo de Araújo
Jaimis Sajid Leon ColquiJaimis Sajid Leon Colqui
Jaimis Sajid Leon Colqui
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
JFJosé Pissolato Filho
José Pissolato Filho
This article investigates the influence of four causal frequency-dependent (FD) soil models and their impact on the responses of a multiphase overhead transmission line (OHTL) with ground wires, generated by a lightning strike. The FD models proposed by Longmire-Smith (LS), Messier (M), Portela (P) and Alípio-Visacro (AV) are considered. The ground-return impedance and admittance matrices are computed with the Nagakawa approach for both frequency-constant and FD soil models. The frequency-domain modal voltages and time-domain transient voltages are assessed in this work. Modal decomposition technique is used to study the attenuation constant, propagation velocity and voltages for each propagation mode. Simulations are carried out in a frequency range of 100 Hz to 10 MHz, for OHTLs with lengths of 1 and 10 km, on soils of 700 and 4000 Ω·m. Simulation results demonstrated that the Portela (P) model has resulted in more significant variation in the ground-return impedance and admittance, constant attenuation and propagation velocity in which a pronounced variation, especially at the high frequencies, is seen. On the other hand, Longmire-Smith (LS) and Messier (M) have produced similar results in both frequency and time domains. Additionally, the Alípio-Visacro (AV) model has produced intermediate responses, being the model recommended by CIGRÈ WG C4.33. Time-domain induced voltage waveforms obtained with the Portela (P) model has shown pronounced differences, especially at the peak values, for the high-resistive soil. This study demonstrates the importance of considering the FD soil models to assess the transient responses adequately, especially when OHTLs are on high-resistive soils.