Eshetu Tadesse Ymer

Mr. Eshetu Tadesse Ymer

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2024 in Heliyon
Verified
Journal Article
Open access
Debela A. TeKlemariyemDebela A. TeKlemariyem
Debela A. TeKlemariyem
EYEshetu Tadesse Ymer
Eshetu Tadesse Ymer
Venkata Ramayya AnchaVenkata Ramayya Ancha
Venkata Ramayya Ancha
BZBalewgize Amare Zeru
Balewgize Amare Zeru
This research examines the optimal 3D geometric parameters and shape of empty diffusers to enhance the mass flow rate of the HAWT rotor plane using a detailed parametric study. Previous works have investigated the use of diffusers to augment turbine power output; however, different curvature surfaces and the effects of all associated angles have not been considered for a thorough evaluation. This work mainly focuses on analyzing the effect of opening angles (2° to 22°), inlet shroud angles (8° to 24°), flange height ratios, flange angles (0° and 15°), and shape of the diffuser as well as flanges on velocity, pressure at the diffuser entry, and through the diffuser section at a wind speed of 4.5 m/s. At an inlet-shroud angle of 24° and an opening angle of 8°, with a diffuser flange height-throat diameter ratio of 0.3, the system achieved an 82.9% increase in flowrate. The diffuser with an inlet shroud-side lower stepped flange showed an optimum velocity of 9.12 m/s (maximum) and 8.2 m/s (average), resulting in a 102.66% and 82.2% increase in velocity, respectively. The percentage increase in velocity of the present study is 92.61%, compared with the previous maximum increase in rate of 53.8%, and then an increase in velocity of 38.81% was obtained. The optimum speed occurred at 0.175 m from the inlet section of the diffuser, indicating where the turbine should best be located. The CFD results from this work were validated with experimental data from the literature, showing a good agreement between the two. Integrated diffuser-turbine system simulation and experimental work with field tests are recommended as a way forward.


1 September 2026 in Environmental Research Communications
Verified
Journal Article
Open access
EYEshetu Tadesse Ymer
Eshetu Tadesse Ymer
HLHirpa G. Lemu
Hirpa G. Lemu
ATAbduselam Aliyi Teso
Abduselam Aliyi Teso
MTMesay Alemu Tolcha
Mesay Alemu Tolcha
This study investigates the aging and performance degradation of crystalline silicon photovoltaic (PV) modules installed in Jimma, Ethiopia, a region characterized by high solar irradiance (5–6 kWh m − 2 d − 1 ), elevated temperatures, and humidity levels up to 85%. Polycrystalline and monocrystalline PV modules, aged 4 to 28 years, were evaluated using a current–voltage measurements normalized to standard test conditions. All modules exhibited significant encapsulant discoloration, cell cracks, and delamination, along with browning and yellowing of ethylene vinyl acetate. The annual degradation rates of power output, short-circuit current, and open-circuit voltage were approximately 1.53%, 0.88%, and 0.67%,with an associated uncertainty of ± 0.32 % for polycrystalline modules, and 1.58%, 1.196%, and 0.616%,with an associated uncertainty of ± 0.0 .26 % for monocrystalline modules, respectively, which exceeds typical manufacturer warranty limits of 0.5% to 0.7% per year. Performance degradation was further worsened by an increase in series resistance, resulting from metalization corrosion, solder joint fatigue, and microcracks, which reduced the fill factor and maximum power output. Concurrently, a decrease in shunt resistance, associated with encapsulant browning, moisture ingress, and delamination, increased leakage currents and reduced carrier collection efficiency. Consequently, power loss was dominated by declines in short-circuit current, linking optical, physical, and resistive degradation to electrical performance deterioration. The fast degradation observed in Jimma highlights the strong influence of high temperature and humidity on PV module longevity, emphasizing the need for climate-specific energy yield predictions and the deployment of PV technologies with enhanced durability in tropical environments.