In this paper, flow characteristics of a two-phase loop thermosyphon under vertical reciprocating vibration are visually investigated with N-pentane as the working fluid. The tests are performed for a heating power range of 20 W to 40 W, the filling ratio of 30 % to 70%, and a 30 m•s-2, 35 Hz vertical reciprocating vibration. The effect of vertical vibration on flow characteristics of the two-phase loop thermosyphon is investigated by comparing the obtained results with those acquired in static, thereby providing a basis for explaining the heat transfer process of two-phase loop thermosyphon under vibration. The results indicate that vertical vibration promotes the rupture of a liquid plug and the transformation of the plug flow to annular flow or wavy flow. Furthermore, the vertical vibration does not change the distribution law of liquid flow velocity in the two-phase loop thermosyphon. However, it will reduce the overheating and flow velocity in the two-phase loop thermosyphon at the start-up. With an increase in the heating power, the influence of vertical vibration on liquid flow velocity is reduced due to continuous disturbance of the working medium in the two-phase loop thermosyphon.
Perfect optical vortices (POVs), consists of a single bright ring structure, has been widely studied owing to its radius independent of orbital angular momentum (OAM). However, most of the existing works about POVs are limited to single ring structure. Flexible shaping of intensity distribution of POVs is vital for multiple applications. In this paper, we propose a method generate phase tunable multi-ring perfect optical vortices (MR-POVs) where each ring size is independent of its OAM. The scheme is based on the radical discontinuous spiral phase plate (RD-SPP) which introduces controllable phase jumps along radial direction. It is experimentally demonstrated that the vortex nature of the MR-POVs through an interferometric method, showing that each ring of MR-POVs possesses same topological charge value (magnitude and sign), and the intensity ratio between each ring can be freely regulated by adjusting phase distribution, which could offer more flexible optical gradient force for guiding and transporting particles. In addition, simulation and experimental results show that the integer and fractional MR-POV can generated by the independent regulation of angular and radial factors. This work expands our understanding of multi-ring POV and may provide a new idea for optical tweezers and OAM communications.
The two phase loop thermosyphon (TPLT) is generally a technique used in conjunction with a fan when cooling an electronic chip to enhance the cooling effect. In this context, the TPLT heat transfer efficiency is directly affected by the vibration caused by the associated fan. In this paper, the heat transfer performances of TPLTs with diameters of 4mm, 6mm and 8mm were experimentally investigated under a heating power capacity ranging from 40 W to 400 W, a filling ratio of 40 % to 70%, and a 30 m•s-2 35 Hz vertical reciprocating vibration. The heat transfer performance of the TPLT is compared to the case of operation under the same working conditions in a static state. The influence of the vibration state caused by the fan rotation on the heat transfer performance of TPLTs with different diameters is analyzed and discussed. The obtained results indicated that vertical vibration does not change the trend of TPLT heat transfer performance with the corresponding heating power capacity under each pipe diameter. On the other hand, it was found that the vibration enhances or inhibits the heat transfer characteristics of TPLT, affected by the pipe diameter, the heating power capacity, and the liquid filling ratio.