Zuzana Kolková

Dr. Zuzana Kolková

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Energy Reports
Verified
Journal Article
Open access
PBPavol Belany
Pavol Belany
PHPeter Hrabovsky
Peter Hrabovsky
ZKZuzana Kolková
Zuzana Kolková

26 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPavol Mičko
Pavol Mičko
DHDávid Hečko
Dávid Hečko
AKAndrej Kapjor
Andrej Kapjor
RNRadovan Nosek
Radovan Nosek
ZKZuzana Kolková
Zuzana Kolková
NKNikola Čajová Kantová
Nikola Čajová Kantová
The high-energy requirements of cleanrooms are the main motivation for optimizing their operational conditions. The ventilation system consumes the most energy in order to ensure the precise air conditioning of the room (filtration, temperature, and humidity adjustment). The main function of the ventilation system is to keep particle concentration to a minimum. This work deals with the optimization of an experimental operating room via the optimization of air supply through the distribution element (laminar airflow ceiling) in the range of 0.15–0.25 m·s−1. The laminar airflow between the distribution element and the patient is influenced by the operating light and different airflow velocities. These factors affect changes in particle concentration. Ansys Fluent software was used to investigate the nature of the flow, velocity profiles, and particle trajectories. The results of our numerical simulation demonstrate that a suitable flow rate setting increases the efficiency of particle reduction in the operating table area by up to 54%, which can, in turn, reduce operating costs. The simulated air velocity profile was subsequently verified using the particle image velocimetry (PIV) method. The typical size of particles monitored for in cleanrooms is 0.5 μm according to ISO EN 7. Therefore, the results of this study should be helpful in correctly designing distribution elements for clean rooms.

1 January 2023 in Technológ
Verified
Journal Article
Open access
PDF file
UŽUniversity of Žilina
University of Žilina
ZKZuzana Kolková
Zuzana Kolková
JMJozef Matušov
Jozef Matušov
AZAugustín Zubo
Augustín Zubo
ASAleš Stupka
Aleš Stupka
JJJan Jandík
Jan Jandík
The comprehensive experimental facility for battery storage introduces an innovative approach to analysing and optimizing the performance of energy storage systems. Designed with consideration for energy flow and overall capacity, it utilizes testing of key components such as batteries with a battery management system and power inverters. The facility, housed in two standard 20ft freight containers, not only enables efficient testing but also offers advantages in terms of cost-effectiveness, customization, mobility, and the possibility of parallel tests. The containers also serve as laboratory cells, providing an isolated environment for precise experiments. The division of the container into three main sections - power, control, and testing - brings a systematic approach to experiments with a focus on safety features. Implemented fire barriers and resilient windows ensure a secure environment for the development and testing of battery storage, contributing to the advancement of modern energy technologies.