Pavol Mičko

Dr. Pavol Mičko

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPavol Mičko
Pavol Mičko
DHDávid Hečko
Dávid Hečko
AKAndrej Kapjor
Andrej Kapjor
RNRadovan Nosek
Radovan Nosek
ZKZuzana Kolková
Zuzana Kolková
NKNikola Čajová Kantová
Nikola Čajová Kantová
The high-energy requirements of cleanrooms are the main motivation for optimizing their operational conditions. The ventilation system consumes the most energy in order to ensure the precise air conditioning of the room (filtration, temperature, and humidity adjustment). The main function of the ventilation system is to keep particle concentration to a minimum. This work deals with the optimization of an experimental operating room via the optimization of air supply through the distribution element (laminar airflow ceiling) in the range of 0.15–0.25 m·s−1. The laminar airflow between the distribution element and the patient is influenced by the operating light and different airflow velocities. These factors affect changes in particle concentration. Ansys Fluent software was used to investigate the nature of the flow, velocity profiles, and particle trajectories. The results of our numerical simulation demonstrate that a suitable flow rate setting increases the efficiency of particle reduction in the operating table area by up to 54%, which can, in turn, reduce operating costs. The simulated air velocity profile was subsequently verified using the particle image velocimetry (PIV) method. The typical size of particles monitored for in cleanrooms is 0.5 μm according to ISO EN 7. Therefore, the results of this study should be helpful in correctly designing distribution elements for clean rooms.

12 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PMPavol Mičko
Pavol Mičko
RNRadovan Nosek
Radovan Nosek
PHPeter Hrabovský
Peter Hrabovský
DHDávid Hečko
Dávid Hečko
Forced ventilation is applied in clean rooms, specifically operating rooms, to ensure the health of both the patient and the medical staff. Ventilation reduces the risk of patient contamination, and its parameters are legally prescribed. In addition to preventing contamination, the ventilation system also ensures the creation of a comfortable environment for personnel who spend a large amount of working time in the operating room. This research focuses on the appropriate design of the air flow rate from the distribution element to the operating room. The PMV and PPD indexes were used to evaluate thermal comfort for human beings. The measurements of parameters determining thermal comfort took place in a laboratory with an accurate model of the operating room, including equipment and HVAC system, during the summer months, in cooling mode. Discharge speeds in the range of 0.15–0.175 m/s were evaluated as the most comfortable, with the PPD index ranging up to 22%. There was a significant increase in user dissatisfaction up to the limit of 70% at higher discharge speeds.

29 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DHDávid Hečko
Dávid Hečko
Milan MalchoMilan Malcho
Milan Malcho
PMPavol Mičko
Pavol Mičko
NKNikola Čajová Kantová
Nikola Čajová Kantová
ZKZuzana Kolková
Zuzana Kolková
PBPavol Belany
Pavol Belany
For countries with limited access to conventional hydrocarbon gases, methane hydrates have emerged as a potential energy source. In view of the European Union’s requirements to reduce the energy intensity of technological processes and increase energy security, it appears promising to accumulate natural gas and biomethane in the form of hydrate structures and release them if necessary. Storing gas in this form in an energy-efficient manner creates interest in developing and innovating technologies in this area. Hydrates that form in gas pipelines are generated by a more or less random process and are an undesirable phenomenon in gas transportation. In our case, the process implemented in the proposed experimental device is a controlled process, which can generate hydrates in orders of magnitude shorter times compared to the classical methods of generating natural gas hydrates in autoclaves by saturating water only. The recirculation of gas-saturated water has been shown to be the most significant factor in reducing the energy consumption of natural gas hydrate generation. Not only is the energy intensity of generation reduced, but also its generation time. In this paper, a circuit diagram for an experimental device for natural gas hydrate generation is shown with complete description, principle of operation, and measurement methodology. The natural gas hydrate formation process is analyzed using a mathematical model that correlates well with the measured hydrate formation times. Hydrates may become a current challenge in the future and, once verified, may find applications in various fields of technology or industry.