Mathias Blandeau

Dr. Mathias Blandeau

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RHRémy Hubaut
Rémy Hubaut
RGRomain GUICHARD
Romain GUICHARD
JGJulia Greenfield
Julia Greenfield
MBMathias Blandeau
Mathias Blandeau
Musculoskeletal disorders in the workplace are a growing problem in Europe. The measurement of these disorders in a working environment presents multiple limitations concerning equipment and measurement reliability. The aim of this study was to evaluate the use of inertial measurement units against a reference system for their use in the workplace. Ten healthy volunteers conducted three lifting methods (snatching, pushing, and pulling) for manhole cover using a custom-made tool weighting 20 and 30 kg. Participants’ back and dominant arm were equipped with IMU, EMG, and reflective markers for VICON analysis and perception of effort was estimated at each trial using a Visual Analog Scale (VAS). The Bland–Altman method was used and results showed good agreement between IMU and VICON systems for Yaw, Pitch and Roll angles (bias values < 1, −4.4 < LOA < 3.6°). EMG results were compared to VAS results and results showed that both are a valuable means to assess efforts during tasks. This study therefore validates the use of inertial measurement units (IMU) for motion capture and its combination with electromyography (EMG) and a Visual Analogic Scale (VAS) to assess effort for use in real work situations.

26 April 2023 in Journal of Biomechanics
Verified
Journal Article
Closed access
MBMathias Blandeau
Mathias Blandeau
RGRomain Guichard
Romain Guichard
RHRémy Hubaut
Rémy Hubaut
SLSébastien Leteneur
Sébastien Leteneur

9 June 2022 in Technologies
Verified
Journal Article
Open access
PDF file
MBMathias Blandeau
Mathias Blandeau
RGRomain GUICHARD
Romain GUICHARD
RHRémy Hubaut
Rémy Hubaut
SLSébastien Leteneur
Sébastien Leteneur
The use of Inertial Measurement Units (IMUs) can provide embedded motion data to improve clinical application. The objective of this study was to validate a newly designed IMU system. The validation is provided through two main methods, a classical sensor validation achieved on a six-degrees-of-freedom hexapod platform with controlled linear and rotation motions and a functional validation on subjects performing squats with segmental angle measurement. The kinematics of the sensors were measured by using an optoelectronic reference system (VICON) and then compared to the orientation and raw data of the IMUs. Bland–Altman plots and Lin’s concordance correlation coefficient were computed to assess the kinematic parameter errors between the IMUs and VICON system. The results showed suitable precision of the IMU system for linear, rotation and squat motions.

18 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
SSseyed Mohammadreza Shokouhyan
seyed Mohammadreza Shokouhyan
MBMathias Blandeau
Mathias Blandeau
LWLaura Wallard
Laura Wallard
TGThierry Marie Guerra
Thierry Marie Guerra
PPPhilippe Pudlo
Philippe Pudlo
FBFranck Barbier
Franck Barbier
Neuro mechanical time delay is inevitable in the sensorimotor control of the body due to sensory, transmission, signal processing and muscle activation delays. In essence, time delay reduces stabilization efficiency, leading to system instability (e.g., falls). For this reason, estimation of time delay in patients such as people living with spinal cord injury (SCI) can help therapists and biomechanics to design more appropriate exercise or assistive technologies in the rehabilitation procedure. In this study, we aim to estimate the muscle onset activation in SCI people by four strategies on EMG data. Seven complete SCI individuals participated in this study, and they maintained their stability during seated balance after a mechanical perturbation exerting at the level of the third thoracic vertebra between the scapulas. EMG activity of eight upper limb muscles were recorded during the stability. Two strategies based on the simple filtering (first strategy) approach and TKEO technique (second strategy) in the time domain and two other approaches of cepstral analysis (third strategy) and power spectrum (fourth strategy) in the time–frequency domain were performed in order to estimate the muscle onset. The results demonstrated that the TKEO technique could efficiently remove the electrocardiogram (ECG) and motion artifacts compared with the simple classical filtering approach. However, the first and second strategies failed to find muscle onset in several trials, which shows the weakness of these two strategies. The time–frequency techniques (cepstral analysis and power spectrum) estimated longer activation onset compared with the other two strategies in the time domain, which we associate with lower-frequency movement in the maintaining of sitting stability. In addition, no correlation was found for the muscle activation sequence nor for the estimated delay value, which is most likely caused by motion redundancy and different stabilization strategies in each participant. The estimated time delay can be used in developing a sensory motor control model of the body. It not only can help therapists and biomechanics to understand the underlying mechanisms of body, but also can be useful in developing assistive technologies based on their stability mechanism.

30 October 2024 in Gait & Posture
Verified
Journal Article
Closed access
JGJulia Greenfield
Julia Greenfield
RGRomain Guichard
Romain Guichard
RKRomain Kubiak
Romain Kubiak
MBMathias Blandeau
Mathias Blandeau

10 August 2025 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
MVMaria Vinti
Maria Vinti
MBMathias Blandeau
Mathias Blandeau
HPHélène Pillet
Hélène Pillet
WSWafa Skalli
Wafa Skalli
PDPhilippe Decq
Philippe Decq
EHEmilie Hutin
Emilie Hutin