Rémy Hubaut

Dr. Rémy Hubaut

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RHRémy Hubaut
Rémy Hubaut
RGRomain GUICHARD
Romain GUICHARD
JGJulia Greenfield
Julia Greenfield
MBMathias Blandeau
Mathias Blandeau
Musculoskeletal disorders in the workplace are a growing problem in Europe. The measurement of these disorders in a working environment presents multiple limitations concerning equipment and measurement reliability. The aim of this study was to evaluate the use of inertial measurement units against a reference system for their use in the workplace. Ten healthy volunteers conducted three lifting methods (snatching, pushing, and pulling) for manhole cover using a custom-made tool weighting 20 and 30 kg. Participants’ back and dominant arm were equipped with IMU, EMG, and reflective markers for VICON analysis and perception of effort was estimated at each trial using a Visual Analog Scale (VAS). The Bland–Altman method was used and results showed good agreement between IMU and VICON systems for Yaw, Pitch and Roll angles (bias values < 1, −4.4 < LOA < 3.6°). EMG results were compared to VAS results and results showed that both are a valuable means to assess efforts during tasks. This study therefore validates the use of inertial measurement units (IMU) for motion capture and its combination with electromyography (EMG) and a Visual Analogic Scale (VAS) to assess effort for use in real work situations.

9 June 2022 in Technologies
Verified
Journal Article
Open access
PDF file
MBMathias Blandeau
Mathias Blandeau
RGRomain GUICHARD
Romain GUICHARD
RHRémy Hubaut
Rémy Hubaut
SLSébastien Leteneur
Sébastien Leteneur
The use of Inertial Measurement Units (IMUs) can provide embedded motion data to improve clinical application. The objective of this study was to validate a newly designed IMU system. The validation is provided through two main methods, a classical sensor validation achieved on a six-degrees-of-freedom hexapod platform with controlled linear and rotation motions and a functional validation on subjects performing squats with segmental angle measurement. The kinematics of the sensors were measured by using an optoelectronic reference system (VICON) and then compared to the orientation and raw data of the IMUs. Bland–Altman plots and Lin’s concordance correlation coefficient were computed to assess the kinematic parameter errors between the IMUs and VICON system. The results showed suitable precision of the IMU system for linear, rotation and squat motions.