Julia Greenfield

Dr. Julia Greenfield

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RHRémy Hubaut
Rémy Hubaut
RGRomain GUICHARD
Romain GUICHARD
JGJulia Greenfield
Julia Greenfield
MBMathias Blandeau
Mathias Blandeau
Musculoskeletal disorders in the workplace are a growing problem in Europe. The measurement of these disorders in a working environment presents multiple limitations concerning equipment and measurement reliability. The aim of this study was to evaluate the use of inertial measurement units against a reference system for their use in the workplace. Ten healthy volunteers conducted three lifting methods (snatching, pushing, and pulling) for manhole cover using a custom-made tool weighting 20 and 30 kg. Participants’ back and dominant arm were equipped with IMU, EMG, and reflective markers for VICON analysis and perception of effort was estimated at each trial using a Visual Analog Scale (VAS). The Bland–Altman method was used and results showed good agreement between IMU and VICON systems for Yaw, Pitch and Roll angles (bias values < 1, −4.4 < LOA < 3.6°). EMG results were compared to VAS results and results showed that both are a valuable means to assess efforts during tasks. This study therefore validates the use of inertial measurement units (IMU) for motion capture and its combination with electromyography (EMG) and a Visual Analogic Scale (VAS) to assess effort for use in real work situations.

20 August 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JKJohannes Knitza
Johannes Knitza
RHRagip Hasanaj
Ragip Hasanaj
JBJonathan Beyer
Jonathan Beyer
FGFranziska Ganzer
Franziska Ganzer
ASAnna Slagman
Anna Slagman
KDKatharina Dechant
Katharina Dechant
Background: Emergency departments (EDs) are frequently overcrowded and increasingly used by nonurgent patients. Symptom checkers (SCs) offer on-demand access to disease suggestions and recommended actions, potentially improving overall patient flow. Contrary to the increasing use of SCs, there is a lack of supporting evidence based on direct patient use. Objective: This study aimed to compare the diagnostic accuracy, safety, usability, and acceptance of 2 SCs, Ada and Symptoma. Methods: A randomized, crossover, head-to-head, double-blinded study including consecutive adult patients presenting to the ED at University Hospital Erlangen. Patients completed both SCs, Ada and Symptoma. The primary outcome was the diagnostic accuracy of SCs. In total, 6 blinded independent expert raters classified diagnostic concordance of SC suggestions with the final discharge diagnosis as (1) identical, (2) plausible, or (3) diagnostically different. SC suggestions per patient were additionally classified as safe or potentially life-threatening, and the concordance of Ada’s and physician-based triage category was assessed. Secondary outcomes were SC usability (5-point Likert-scale: 1=very easy to use to 5=very difficult to use) and SC acceptance net promoter score (NPS). Results: A total of 450 patients completed the study between April and November 2021. The most common chief complaint was chest pain (160/437, 37%). The identical diagnosis was ranked first (or within the top 5 diagnoses) by Ada and Symptoma in 14% (59/437; 27%, 117/437) and 4% (16/437; 13%, 55/437) of patients, respectively. An identical or plausible diagnosis was ranked first (or within the top 5 diagnoses) by Ada and Symptoma in 58% (253/437; 75%, 329/437) and 38% (164/437; 64%, 281/437) of patients, respectively. Ada and Symptoma did not suggest potentially life-threatening diagnoses in 13% (56/437) and 14% (61/437) of patients, respectively. Ada correctly triaged, undertriaged, and overtriaged 34% (149/437), 13% (58/437), and 53% (230/437) of patients, respectively. A total of 88% (385/437) and 78% (342/437) of participants rated Ada and Symptoma as very easy or easy to use, respectively. Ada’s NPS was –34 (55% [239/437] detractors; 21% [93/437] promoters) and Symptoma’s NPS was –47 (63% [275/437] detractors and 16% [70/437]) promoters. Conclusions: Ada demonstrated a higher diagnostic accuracy than Symptoma, and substantially more patients would recommend Ada and assessed Ada as easy to use. The high number of unrecognized potentially life-threatening diagnoses by both SCs and inappropriate triage advice by Ada was alarming. Overall, the trustworthiness of SC recommendations appears questionable. SC authorization should necessitate rigorous clinical evaluation studies to prevent misdiagnoses, fatal triage advice, and misuse of scarce medical resources. Trial Registration: German Register of Clinical Trials DRKS00024830; https://drks.de/search/en/trial/DRKS00024830

14 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JGJulia Greenfield
Julia Greenfield
VDVéronique Delcroix
Véronique Delcroix
WEWafae Ettaki
Wafae Ettaki
RDRomain Derollepot
Romain Derollepot
LPLaurence Pair-Ficout
Laurence Pair-Ficout
MRMaud Ranchet
Maud Ranchet
Cortical activity and walking speed are known to decline with age and can lead to an increased risk of falls in the elderly. Despite age being a known contributor to this decline, individuals age at different rates. This study aimed to analyse left and right cortical activity changes in elderly adults regarding their walking speed. Cortical activation and gait data were obtained from 50 healthy older individuals. Participants were then grouped into a cluster based on their preferred walking speed (slow or fast). Analyses on the differences of cortical activation and gait parameters between groups were carried out. Within-subject analyses on left and right–hemispheric activation were also performed. Results showed that individuals with a slower preferred walking speed required a higher increase in cortical activity. Individuals in the fast cluster presented greater changes in cortical activation in the right hemisphere. This work demonstrates that categorizing older adults by age is not necessarily the most relevant method, and that cortical activity can be a good indicator of performance with respect to walking speed (linked to fall risk and frailty in the elderly). Future work may wish to explore how physical activity training influences cortical activation over time in the elderly.

19 January 2024 in JMIR Preprints
Verified
Preprint
Open access
JKJohannes Knitza
Johannes Knitza
RHRagip Hasanaj
Ragip Hasanaj
JBJonathan Beyer
Jonathan Beyer
FGFranziska Ganzer
Franziska Ganzer
ASAnna Slagman
Anna Slagman
KDKatharina Dechant
Katharina Dechant
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Emergency departments (EDs) are frequently overcrowded and increasingly used by nonurgent patients. Symptom checkers (SCs) offer on-demand access to disease suggestions and recommended actions, potentially improving overall patient flow. Contrary to the increasing use of SCs, there is a lack of supporting evidence based on direct patient use. Objective: This study aimed to compare the diagnostic accuracy, safety, usability, and acceptance of 2 SCs, Ada and Symptoma. Methods: A randomized, crossover, head-to-head, double-blinded study including consecutive adult patients presenting to the ED at University Hospital Erlangen. Patients completed both SCs, Ada and Symptoma. The primary outcome was the diagnostic accuracy of SCs. In total, 6 blinded independent expert raters classified diagnostic concordance of SC suggestions with the final discharge diagnosis as (1) identical, (2) plausible, or (3) diagnostically different. SC suggestions per patient were additionally classified as safe or potentially life-threatening, and the concordance of Ada’s and physician-based triage category was assessed. Secondary outcomes were SC usability (5-point Likert-scale: 1=very easy to use to 5=very difficult to use) and SC acceptance net promoter score (NPS). Results: A total of 450 patients completed the study between April and November 2021. The most common chief complaint was chest pain (160/437, 37%). The identical diagnosis was ranked first (or within the top 5 diagnoses) by Ada and Symptoma in 14% (59/437; 27%, 117/437) and 4% (16/437; 13%, 55/437) of patients, respectively. An identical or plausible diagnosis was ranked first (or within the top 5 diagnoses) by Ada and Symptoma in 58% (253/437; 75%, 329/437) and 38% (164/437; 64%, 281/437) of patients, respectively. Ada and Symptoma did not suggest potentially life-threatening diagnoses in 13% (56/437) and 14% (61/437) of patients, respectively. Ada correctly triaged, undertriaged, and overtriaged 34% (149/437), 13% (58/437), and 53% (230/437) of patients, respectively. A total of 88% (385/437) and 78% (342/437) of participants rated Ada and Symptoma as very easy or easy to use, respectively. Ada’s NPS was –34 (55% [239/437] detractors; 21% [93/437] promoters) and Symptoma’s NPS was –47 (63% [275/437] detractors and 16% [70/437]) promoters. Conclusions: Ada demonstrated a higher diagnostic accuracy than Symptoma, and substantially more patients would recommend Ada and assessed Ada as easy to use. The high number of unrecognized potentially life-threatening diagnoses by both SCs and inappropriate triage advice by Ada was alarming. Overall, the trustworthiness of SC recommendations appears questionable. SC authorization should necessitate rigorous clinical evaluation studies to prevent misdiagnoses, fatal triage advice, and misuse of scarce medical resources. Trial Registration: German Register of Clinical Trials DRKS00024830; https://drks.de/search/en/trial/DRKS00024830

22 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
JWJun Wang
Jun Wang
JGJulia Greenfield
Julia Greenfield
PMPeter Mitrouchev
Peter Mitrouchev
GLGuiqin Li
Guiqin Li
FQFranck Quaine
Franck Quaine
During manual operations, the human brain relies on mediated visual stimuli such as color to estimate an object’s weight and adjust muscle force through the central nervous system (CNS). This study examines the neuromuscular “reality gap” induced by the color–weight illusion (CWI) during repetitive lifting tasks in an augmented reality (AR) interface. We analyzed the median frequency (MDF) and Co-Contraction Index (CCI) of the biceps and triceps muscles to quantify physiological strain under varying luminance conditions in both AR and physical environments. The results reveal that AR significantly amplifies the CWI, with black stimuli triggering an aggressive joint-stiffening strategy in the AR group (APG). Compared with the physical reality group, the AR group showed lower overall endurance (91.4 ± 22.8 vs. 100.1 ± 12.5 repetitions) and a stronger physiological response to the black stimulus. In the AR group, the black condition was associated with a terminal CCI of 84.7 ± 25.4% and an MDF decline of approximately 21.7 Hz, whereas the corresponding contrast was attenuated in the physical reality group. These findings demonstrate a critical decoupling between behavioral output and internal physiological strain, indicating that the CNS treats virtual visual cues as high-reliability signals that increase metabolic “bio-cost” despite task completion parity. This research identifies a “masking effect” where behavioral metrics hide severe ergonomic risks, providing novel approaches for managing musculoskeletal health in industrial settings and personalizing coordination training in clinical rehabilitation.

15 July 2025 in EULAR Rheumatology Open
Verified
Journal Article
Open access
JKJohannes Knitza
Johannes Knitza
JMJohanna Mucke
Johanna Mucke
FMFelix Muehlensiepen
Felix Muehlensiepen
TXTingting Xiong
Tingting Xiong
MGManuel Grahammer
Manuel Grahammer
MKMartin Krusche
Martin Krusche
The growing shortage of rheumatologists threatens rheumatology care. Patient self-assessment and asynchronous virtual visits may improve efficiency. This study assessed the concordance of face-to-face (F2F) and virtual visit-based treatment decisions in individuals with rheumatoid arthritis (RA), incorporating patient self-assessment. This prospective 3-month multicentre trial recruited RA patients across 4 university centres in Germany. Patients used a medical app to document the results of a self-performed C-reactive protein (CRP) test, joint count, therapeutic suggestions, and electronic patient-reported outcomes (ePROs) before their regular F2F consultations and ePROs on a weekly basis in-between consultations. Independent tele-rheumatologists provided treatment recommendations based on these data. The primary outcome was the level of agreement between tele-rheumatologists and patients on treatment decisions (escalation, unchanged, de-escalation), compared with F2F rheumatologists’ decisions. Secondary outcomes included change in patient activation (Patient Activation Measure [PAM]) and in patient-perceived ability to assess their disease activity. A total of 208 consultations and 114 patients (80.7% female, mean age 51.6 years) were included. Most often (63%), treatment remained unchanged, whereas 24% required escalation and 14% de-escalation. F2F treatment decisions aligned with tele-rheumatologist decisions in 77% of cases and patient suggestions in 67% of cases. The accuracy of tele-rheumatologist decisions was 77% for maintaining treatment, 87% for de-escalation, and 91% for escalation. No significant changes in patient activation and patients’ ability to assess their disease activity were observed. The study demonstrated substantial agreement between virtual asynchronous and F2F treatment decisions. However, further refinement of asynchronous care models and validation studies is crucial.