Musculoskeletal disorders in the workplace are a growing problem in Europe. The measurement of these disorders in a working environment presents multiple limitations concerning equipment and measurement reliability. The aim of this study was to evaluate the use of inertial measurement units against a reference system for their use in the workplace. Ten healthy volunteers conducted three lifting methods (snatching, pushing, and pulling) for manhole cover using a custom-made tool weighting 20 and 30 kg. Participants’ back and dominant arm were equipped with IMU, EMG, and reflective markers for VICON analysis and perception of effort was estimated at each trial using a Visual Analog Scale (VAS). The Bland–Altman method was used and results showed good agreement between IMU and VICON systems for Yaw, Pitch and Roll angles (bias values < 1, −4.4 < LOA < 3.6°). EMG results were compared to VAS results and results showed that both are a valuable means to assess efforts during tasks. This study therefore validates the use of inertial measurement units (IMU) for motion capture and its combination with electromyography (EMG) and a Visual Analogic Scale (VAS) to assess effort for use in real work situations.
The use of Inertial Measurement Units (IMUs) can provide embedded motion data to improve clinical application. The objective of this study was to validate a newly designed IMU system. The validation is provided through two main methods, a classical sensor validation achieved on a six-degrees-of-freedom hexapod platform with controlled linear and rotation motions and a functional validation on subjects performing squats with segmental angle measurement. The kinematics of the sensors were measured by using an optoelectronic reference system (VICON) and then compared to the orientation and raw data of the IMUs. Bland–Altman plots and Lin’s concordance correlation coefficient were computed to assess the kinematic parameter errors between the IMUs and VICON system. The results showed suitable precision of the IMU system for linear, rotation and squat motions.
Optoelectronic motion capture systems using reflective markers are widely employed to quantify human movement. Conventional shoe-mounted markers provide only an indirect estimate of foot motion because they assume that foot and shoe move as a single segment. The aim of this proof-of-concept study was to develop and evaluate a magnetic marker-based method for quantifying foot motion within a shoe. The process uses pairs of disc-shaped neodymium magnets, with one magnet attached to the foot and the other embedded in a marker on the shoe surface. In this configuration, this magnetic marker can follow the magnet placed on the foot in motion by sliding along the surface of the shoe. Controlled movements of a rigid 3D-printed foot were performed inside an immobile shoe using a six-axis robotic arm. The magnetic marker method and the conventional method using taped markers on the shoe surface were compared with the reference displacement of the foot within the shoe during 2 rotational and 1 translational movements. While the taped markers remained fixed in their initial positions, the magnetic markers captured at least 63%, and up to 91%, of the reference foot motion. This innovative magnetic marker method represents a breakthrough by successfully tracking in-shoe foot motions. It opens up highly promising perspectives for motion analysis in research, rehabilitation, and ergonomics, including applications for footwear manufacturers, as it effectively addresses the long-standing “hidden foot” problem.
Un modèle complet permettant de simuler la dynamique d'un nano-aérosol est présenté et discuté. On considère une équation Eulérienne de type « Diffusion-Inertia » réécrite en moments en incluant un terme source de coagulation. Le phénomène de dépôt est pris en compte par l'intermédiaire d'une condition aux limites sur le flux de moments à la paroi. L'expression de la granulométrie en moments permet d'obtenir une très bonne efficacité de calcul et rend ainsi le modèle utilisable pour des applications industrielles ou en santé au travail. L'implémentation de cette approche dans un code de CFD est validée sur des cas simples par comparaison avec une méthode des classes ainsi que des données expérimentales. La méthode des moments n'introduit pas de biais particulier et les résultats numériques sont en accord avec les résultats expérimentaux. Un nouveau dispositif expérimental, qui consiste en une enceinte ventilée, est également proposé afin de maîtriser au mieux l'écoulement et de caractériser la morphologie des agrégats générés. La confrontation entre les résultats numériques et expérimentaux met en évidence le fait que la détermination des paramètres fractals est un élément clé de la modélisation