Luigi Brancato

Mr. Luigi Brancato

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2019 in Micromachines
Verified
Journal Article
Open access
DKDries Kil
Dries Kil
MCMarta Bovet Carmona
Marta Bovet Carmona
FCFrederik Ceyssens
Frederik Ceyssens
MDMarjolijn Deprez
Marjolijn Deprez
LBLuigi Brancato
Luigi Brancato
RPRobert Puers
Robert Puers
In the quest for chronically reliable and bio-tolerable brain interfaces there has been a steady evolution towards the use of highly flexible, polymer-based electrode arrays. The reduced mechanical mismatch between implant and brain tissue has shown to reduce the evoked immune response, which in turn has a positive effect on signal stability and noise. Unfortunately, the low stiffness of the implants also has practical repercussions, making surgical insertion extremely difficult. In this work we explore the use of dextran as a coating material that temporarily stiffens the implant, preventing buckling during insertion. The mechanical properties of dextran coated neural probes are characterized, as well as the different parameters which influence the dissolution rate. Tuning parameters, such as coating thickness and molecular weight of the used dextran, allows customization of the stiffness and dissolution time to precisely match the user’s needs. Finally, the immunological response to the coated electrodes was analyzed by performing a histological examination after four months of in vivo testing. The results indicated that a very limited amount of glial scar tissue was formed. Neurons have also infiltrated the area that was initially occupied by the dissolving dextran coating. There was no noticeable drop in neuron density around the site of implantation, confirming the suitability of the coating as a temporary aid during implantation of highly flexible polymer-based neural probes.

8 August 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
LBLuigi Brancato
Luigi Brancato
GKGrim Keulemans
Grim Keulemans
TVTom Verbelen
Tom Verbelen
BMBart Meyns
Bart Meyns
RPRobert Puers
Robert Puers
The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS) pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD). A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS) and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode) and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg) and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h). During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

29 April 2022 in Biomolecules
Verified
Journal Article
Open access
PDF file
Costanza Eleonora MauriciCostanza Eleonora Maurici
Costanza Eleonora Maurici
RCRobin Colenbier
Robin Colenbier
BWBritta Wylleman
Britta Wylleman
LBLuigi Brancato
Luigi Brancato
EZEke Myrte van Zwol
Eke Myrte van Zwol
JBJohannes Bogers
Johannes Bogers
Chemotherapy (CT) is the standard care for advanced pancreatic ductal adenocarcinoma (PDAC); however, with limited efficacy. Hyperthermia (HT) treatment has been suggested as a sensitizer to improve outcomes. However, the direct effect of the HT and CT combination is not fully understood. Therefore, we aim to assess the direct cytotoxic effect of HT in PDAC cells as monotherapy or in combination with chemotherapeutics. Different temperatures (37-, 40.5-, 41-, and 41.5 °C) and durations (6-, 12-, and 24 h) were tested in PDAC cell lines (BxPC-3, Capan-1, Capan-2, PANC-1, and MIA-PaCa-2). Different concentrations of gemcitabine, 5-fluorouracil, and cisplatin were also tested in these conditions. The impact on cell metabolic activity was determined by an MTS assay. Enhancement of chemosensitivity was assessed by a reduction in half-maximal inhibitory concentration (IC50). HT and chemotherapeutics interactions were classified as antagonistic, additive, or synergistic using the combination index. HT inhibited cell proliferation in a cell type, temperature, and duration-dependent manner. The induction of apoptosis was seen after 6 h of HT treatment, eventually followed by secondary necrosis. The HT and CT combination led to an IC50 reduction of the tested CT. At 12 h of HT, this effect was between 25 to 90% and reached a 95% reduction at 24 h. The additive or synergistic effect was demonstrated in all cell lines and chemotherapeutics, although, again, this depended on cell type, duration, and temperature. HT is cytotoxic and enhances the therapeutic effectiveness of gemcitabine, 5-fluorouracil, and cisplatin on PDAC cells. This result was further confirmed by the decrease in the expression of RRM2, TS, and ERCC1 in BxPC-3 and Capan-2 cells. These observations warrant further study in specific subsets of PDAC patients to improve their clinical outcomes.

29 June 2018 in Materials
Verified
Journal Article
Open access
PDF file
LBLuigi Brancato
Luigi Brancato
DDDeborah Decrop
Deborah Decrop
Jeroen LammertynJeroen Lammertyn
Jeroen Lammertyn
RPRobert Puers
Robert Puers
This paper investigates the effects on the blood compatibility of surface nanostructuring of Parylene-C coating. The proposed technique, based on the consecutive use of O2 and SF6 plasma, alters the surface roughness and enhances the intrinsic hydrophobicity of Parylene-C. The degree of hydrophobicity of the prepared surface can be precisely controlled by opportunely adjusting the plasma exposure times. Static contact angle measurements, performed on treated Parylene-C, showed a maximum contact angle of 158°. The nanostructured Parylene-C retained its hydrophobicity up to 45 days, when stored in a dry environment. Storing the samples in a body-mimicking solution caused the contact angle to progressively decrease. However, at the end of the measurement, the plasma treated surfaces still exhibited a higher hydrophobicity than the untreated counterparts. The proposed treatment improved the performance of the polymer as a water diffusion barrier in a body simulating environment. Modifying the nanotopography of the polymer influences the adsorption of different blood plasma proteins. The adsorption of albumin—a platelet adhesion inhibitor—and of fibrinogen—a platelet adhesion promoter—was studied by fluorescence microscopy. The adsorption capacity increased monotonically with increasing hydrophobicity for both studied proteins. The effect on albumin adsorption was considerably higher than on fibrinogen. Study of the proteins simultaneous adsorption showed that the albumin to fibrinogen adsorbed ratio increases with substrate hydrophobicity, suggesting lower thrombogenicity of the nanostructured surfaces. Animal experiments proved that the treated surfaces did not trigger any blood clot or thrombus formation when directly exposed to the arterial blood flow. The findings above, together with the exceptional mechanical and insulation properties of Parylene-C, support its use for packaging implants chronically exposed to the blood flow.

13 May 2019 in IEEE Sensors Letters
Verified
Journal Article
Closed access
JBJuncheng Bao
Juncheng Bao
Sen YANSen YAN
Sen YAN
TMTomislav Markovic
Tomislav Markovic
IOIlja Ocket
Ilja Ocket
DKDries Kil
Dries Kil
BNBart Nauwelaers
Bart Nauwelaers
In this paper, a miniaturized microwave resonator is designed and fabricated. A loop mode resonance is created when the permittivity difference of the two materials loaded in the two fluidic channels are sufficiently large. A highly concentrated electrical field is generated in a microfluidic channel loaded with deionized water to achieve high sensing spatial resolution within a sensing volume of 45 pL. On-wafer measurements are performed by keeping one channel unloaded as a reference while loading the other channel with different mixtures of isopropanol and deionized water. The acquired microwave-microfluidic measurements confirm that the proposed resonator can resolve changes in the permittivity of the loaded liquid between the values of 3.2 and 42.4, making it promising for applications such as mixing monitoring and flow cytometry.

16 June 2022 in International Journal of Hyperthermia
Verified
Journal Article
Open access
HPH. Peeters
H. Peeters
EZEke Myrte van Zwol
Eke Myrte van Zwol
LBLuigi Brancato
Luigi Brancato
MCMarina Gabriela Monteiro Carvalho Mori Da Cunha
Marina Gabriela Monteiro Carvalho Mori Da Cunha
JBJohannes Bogers
Johannes Bogers
The use of heat to treat various diseases is called hyperthermia treatment (HT). Since the 1970s, the anti-cancer effects of HT have been investigated. Different HT techniques can be categorized as...