Kenichiro Nagayashi

Kenichiro Nagayashi


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LGLuciano Gottardi
Luciano Gottardi
KNKenichiro Nagayashi
Kenichiro Nagayashi
The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition-edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector physics and describe the recent breakthroughs in the TES design that are opening the way towards the fabrication and the read-out of very large arrays of pixels with unprecedented energy resolution. The most challenging low temperature instruments for space- and ground-base experiments will be described.

9 December 2019 in Journal of Low Temperature Physics
Verified
Journal Article
Closed access
PDF file
KNKenichiro Nagayashi
Kenichiro Nagayashi
MRM. L. Ridder
M. L. Ridder
MBM. P. Bruijn
M. P. Bruijn
LGL. Gottardi
L. Gottardi
ETE. Taralli
E. Taralli
JGJ.-R. Gao
J.-R. Gao

1 November 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HAH. Akamatsu
H. Akamatsu
DVD. Vaccaro
D. Vaccaro
LGLuciano Gottardi
Luciano Gottardi
JKJ. van der Kuur
J. van der Kuur
CVC. P. de Vries
C. P. de Vries
JHJ.-W. A. Den Herder
J.-W. A. Den Herder
We report on the development and demonstration of MHz frequency domain multiplexing (FDM) technology to readout arrays of cryogenic transition edge sensor (TES) x-ray microcalorimeters. In our FDM scheme, TESs are AC biased at different resonant frequencies in the low MHz range through an array of high-Q LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-Q LC filters, and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed x-ray spectral resolutions @ 5.9 keV are ΔE31pix MUX=2.14 ± 0.03 eV and ΔE37pix MUX=2.23 ± 0.03 eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution, to increase the number of multiplexed TESs, and to open up applications for TES x-ray microcalorimeters.

8 December 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
MWMartin de Wit
Martin de Wit
LGL. Gottardi
L. Gottardi
Emanuele TaralliEmanuele Taralli
Emanuele Taralli
KNKenichiro Nagayashi
Kenichiro Nagayashi
MRM. L. Ridder
M. L. Ridder
JHJ.-W. A. Den Herder
J.-W. A. Den Herder
We are developing large Transition Edge Sensor (TES) arrays in combination with a frequency domain multiplexing readout for the next generation of X-ray space observatories. For operation under an AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help us to mitigate non-ideal behavior due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters α and β , as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of 2.03 ± 0.17 eV at 5.9 keV and a best achieved resolution of 1.63 ± 0.17 eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.

21 September 2020 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YNY. Nakashima
Y. Nakashima
FHF. Hirayama
F. Hirayama
SKS. Kohjiro
S. Kohjiro
HYH. Yamamori
H. Yamamori
SNS. Nagasawa
S. Nagasawa
JHJ. W. A. Den Herder
J. W. A. Den Herder
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9   μ Φ 0 / Hz (where Φ 0 is the magnetic flux quantum), equivalent to 9   pA / Hz . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼ 2   μ Φ 0 / Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12   μ s . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼ 10 % contribution of readout noise, i.e., 0.9–1.7 eV.

25 August 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
MWMartin de Wit
Martin de Wit
LGL. Gottardi
L. Gottardi
MRM.L. Ridder
M.L. Ridder
KNKenichiro Nagayashi
Kenichiro Nagayashi
Emanuele TaralliEmanuele Taralli
Emanuele Taralli
JGJ.R. Gao
J.R. Gao
Transition-edge-sensor (TES) microcalorimeters and bolometers are used for a variety of applications. The sensors are based on the steep temperature-dependent resistance of the normal-to-superconducting transition, and are thus intrinsically sensitive to magnetic fields. Conventionally the detectors are shielded from stray magnetic fields using external magnetic shields. However, in particular for applications with strict limits on the available space and mass of an instrument, external magnetic shields might not be enough to obtain the required shielding factors or field homogeneity. Additionally, these shields are only effective for magnetic fields generated external to the TES array, and are ineffective to mitigate the impact of internally generated magnetic fields. Here we present an alternative shielding method based on a superconducting groundplane deposited directly on the backside of the silicon nitride membrane on which the TESs are located. We demonstrate that this local shielding for external magnetic fields has a shielding factor of at the least approximately 80, and is also effective at reducing internal self-induced magnetic fields, as demonstrated by measurements and simulation of the eddy current losses in our ac-biased detectors. Measurements of 5.9-keV x-ray photons show that our shielded detectors have a high resilience to external magnetic fields, showing no degradation of the energy resolution or shifts of the energy-scale calibration for fields of several microtesla, values higher than expected in typical real-world applications.