The increasing demand for light emitting diodes (LEDs) is driven by a number of application categories, including display backlighting, communications, signage, and general illumination. Nowadays, they have also become attractive candidates as new photometric standards. In recent years, LEDs have started to be applied as wavelength-selective photo-detectors as well. Nevertheless, manufacturers’ datasheets are limited about LEDs used as sources in terms of degradation with operating time (aging) or shifting of the emission spectrum as a function of the forward current. On the contrary, as far as detection is concerned, information about spectral responsivity of LEDs is missing. We investigated, mainly from a radiometric point of view, more than 50 commercial LEDs of a wide variety of wavelength bands, ranging from ultraviolet (UV) to near infrared (NIR). Originally, the final aim was to find which LEDs could better work together as detector-emitter pairs for the creation of self-calibrating ground-viewing LED radiometers; however, the findings that we are sharing here following, have a general validity that could be exploited in several sensing applications.
We report on the development and demonstration of MHz frequency domain multiplexing (FDM) technology to readout arrays of cryogenic transition edge sensor (TES) x-ray microcalorimeters. In our FDM scheme, TESs are AC biased at different resonant frequencies in the low MHz range through an array of high-Q LC resonators. The current signals of all TESs are summed at superconducting quantum interference devices (SQUIDs). We have demonstrated multiplexing for a readout of 31 pixels using room temperature electronics, high-Q LC filters, and TES arrays developed at SRON, and SQUID arrays from VTT. We repeated this on a second setup with 37 pixels. The summed x-ray spectral resolutions 5.9 keV are eV and eV. The demonstrated results are comparable with other multiplexing approaches. There is potential to further improve the spectral resolution, to increase the number of multiplexed TESs, and to open up applications for TES x-ray microcalorimeters.
We are developing large Transition Edge Sensor (TES) arrays in combination with a frequency domain multiplexing readout for the next generation of X-ray space observatories. For operation under an AC-bias, the TESs have to be carefully designed and optimized. In particular, the use of high aspect ratio devices will help us to mitigate non-ideal behavior due to the weak-link effect. In this paper, we present a full characterization of a TES array containing five different device geometries, with aspect ratios (width:length) ranging from 1:2 up to 1:6. The complex impedance of all geometries is measured in different bias configurations to study the evolution of the small-signal limit superconducting transition parameters and , as well as the excess noise. We show that high aspect ratio devices with properly tuned critical temperatures (around 90 mK) can achieve excellent energy resolution, with an array average of eV at 5.9 keV and a best achieved resolution of eV. This demonstrates that AC-biased TESs can achieve a very competitive performance compared to DC-biased TESs. The results have motivated a push to even more extreme device geometries currently in development.
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.
14 November 2019 in Journal of Low Temperature Physics
Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of x-ray space observatories. These arrays are required to achieve an energy resolution ΔE < 3 eV full width at half maximum (FWHM) in the soft x-ray energy range. We are currently developing x-ray microcalorimeter arrays for use in the future laboratory and space-based x-ray astrophysics experiments and ground-based spectrometers. In this contribution, we report on the development and the characterization of a uniform 32 × 32 pixel array with 140 × 30 μm2 Ti/Au TESs with the Au x-ray absorber. We report on extensive measurements on 60 pixels in order to show the uniformity of our large TES array. The averaged critical temperature is Tc = 89.5 ± 0.5 mK, and the variation across the array (∼1 cm) is less than 1.5 mK. We found a large region of detector’s bias points between 20% and 40% of the normal-state resistance where the energy resolution is constantly lower than 3 eV. In particular, results show a summed x-ray spectral resolution ΔEFWHM = 2.50 ± 0.04 eV at a photon energy of 5.9 keV, measured in a single-pixel mode using a frequency domain multiplexing readout system developed at SRON/VTT at bias frequencies ranging from 1 MHz to 5 MHz. Moreover, we compare the logarithmic resistance sensitivity with respect to temperature and current (α and β, respectively) and their correlation with the detector’s noise parameter M, showing a homogeneous behavior for all the measured pixels in the array.