James Tung

Dr. James Tung

Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2017 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
APArjun Puri
Arjun Puri
BKBen Kim
Ben Kim
ONOlivier Nguyen
Olivier Nguyen
PSPaul Stolee
Paul Stolee
JTJames Tung
James Tung
JLJoon Lee
Joon Lee
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.

1 March 2021 in Gait & Posture
Verified
Journal Article
Closed access
MNMina Nouredanesh
Mina Nouredanesh
Alan GodfreyAlan Godfrey
Alan Godfrey
JHJennifer Howcroft
Jennifer Howcroft
Edward LemaireEdward Lemaire
Edward Lemaire
JTJames Tung
James Tung

22 April 2015 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
JTJames Tung
James Tung
TLTea Lulic
Tea Lulic
DGDave A Gonzalez
Dave A Gonzalez
JTJohnathan Tran
Johnathan Tran
CDClark Dickerson
Clark Dickerson
EREric A Roy
Eric A Roy
Although motion analysis is frequently employed in upper limb motor assessment (e.g. visually-guided reaching), they are resource-intensive and limited to laboratory settings. This study evaluated the reliability and accuracy of a new markerless motion capture device, the Leap Motion controller, to measure finger position. Testing conditions that influence reliability and agreement between the Leap and a research-grade motion capture system were examined. Nine healthy young adults pointed to 15 targets on a computer screen under two conditions: (1) touching the target (touch) and (2) 4?cm away from the target (no-touch). Leap data was compared to an Optotrak marker attached to the index finger. Across all trials, root mean square (RMS) error of the Leap system was 17.30?????9.56?mm (mean???SD), sampled at 65.47?????21.53?Hz. The % viable trials and mean sampling rate were significantly lower in the touch condition (44% versus 64%, p?<?0.001; 52.02?????2.93 versus 73.98?????4.48?Hz, p = 0.003). While linear correlations were high (horizontal: r2 = 0.995, vertical r2 = 0.945), the limits of agreement were large (horizontal:??22.02 to +26.80?mm, vertical:??29.41 to +30.14?mm). While not as precise as more sophisticated optical motion capture systems, the Leap Motion controller is sufficiently reliable for measuring motor performance in pointing tasks that do not require high positional accuracy (e.g. reaction time, Fitt?s, trails, bimanual coordination).

5 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LSLeia C. Shum
Leia C. Shum
RFReza Faieghi
Reza Faieghi
TBTerry Borsook
Terry Borsook
TFTamim Faruk
Tamim Faruk
SKSouraiya Kassam
Souraiya Kassam
AIAndrea Iaboni
Andrea Iaboni
Real-time location systems (RTLS) record locations of individuals over time and are valuable sources of spatiotemporal data that can be used to understand patterns of human behaviour. Location data are used in a wide breadth of applications, from locating individuals to contact tracing or monitoring health markers. To support the use of RTLS in many applications, the varied ways location data can describe patterns of human behaviour should be examined. The objective of this review is to investigate behaviours described using indoor location data, and particularly the types of features extracted from RTLS data to describe behaviours. Four major applications were identified: health status monitoring, consumer behaviours, developmental behaviour, and workplace safety/efficiency. RTLS data features used to analyse behaviours were categorized into four groups: dwell time, activity level, trajectory, and proximity. Passive sensors that provide non-uniform data streams and features with lower complexity were common. Few studies analysed social behaviours between more than one individual at once. Less than half the health status monitoring studies examined clinical validity against gold-standard measures. Overall, spatiotemporal data from RTLS technologies are useful to identify behaviour patterns, provided there is sufficient richness in location data, the behaviour of interest is well-characterized, and a detailed feature analysis is undertaken.

3 November 2020 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
ELEmily Lam
Emily Lam
SAShahrose Aratia
Shahrose Aratia
JWJulian Wang
Julian Wang
JTJames Tung
James Tung
Background: Heart rate variability (HRV) is used to assess cardiac health and autonomic nervous system capabilities. With the growing popularity of commercially available wearable technologies, the opportunity to unobtrusively measure HRV via photoplethysmography (PPG) is an attractive alternative to electrocardiogram (ECG), which serves as the gold standard. PPG measures blood flow within the vasculature using color intensity. However, PPG does not directly measure HRV; it measures pulse rate variability (PRV). Previous studies comparing consumer-grade PRV with HRV have demonstrated mixed results in short durations of activity under controlled conditions. Further research is required to determine the efficacy of PRV to estimate HRV under free-living conditions. Objective: This study aims to compare PRV estimates obtained from a consumer-grade PPG sensor with HRV measurements from a portable ECG during unsupervised free-living conditions, including sleep, and examine factors influencing estimation, including measurement conditions and simple editing methods to limit motion artifacts. Methods: A total of 10 healthy adults were recruited. Data from a Microsoft Band 2 and a Shimmer3 ECG unit were recorded simultaneously using a smartphone. Participants wore the devices for >90 min during typical day-to-day activities and while sleeping. After filtering, ECG data were processed using a combination of discrete wavelet transforms and peak-finding methods to identify R-R intervals. P-P intervals were edited for deletion using methods based on outlier detection and by removing sections affected by motion artifacts. Common HRV metrics were compared, including mean N-N, SD of N-N intervals, percentage of subsequent differences >50 ms (pNN50), root mean square of successive differences, low-frequency power (LF), and high-frequency power. Validity was assessed using root mean square error (RMSE) and Pearson correlation coefficient (R2). Results: Data sets for 10 days and 9 corresponding nights were acquired. The mean RMSE was 182 ms (SD 48) during the day and 158 ms (SD 67) at night. R2 ranged from 0.00 to 0.66, with 2 of 19 (2 nights) trials considered moderate, 7 of 19 (2 days, 5 nights) fair, and 10 of 19 (8 days, 2 nights) poor. Deleting sections thought to be affected by motion artifacts had a minimal impact on the accuracy of PRV measures. Significant HRV and PRV differences were found for LF during the day and R-R, SDNN, pNN50, and LF at night. For 8 of the 9 matched day and night data sets, R2 values were higher at night (P=.08). P-P intervals were less sensitive to rapid R-R interval changes. Conclusions: Owing to overall poor concurrent validity and inconsistency among participant data, PRV was found to be a poor surrogate for HRV under free-living conditions. These findings suggest that free-living HRV measurements would benefit from examining alternate sensing methods, such as multiwavelength PPG and wearable ECG.

17 October 2019 in Developmental Psychobiology
Verified
Journal Article
Closed access
PDF file
ENEwa Niechwiej-Szwedo
Ewa Niechwiej-Szwedo
KMKimberly Meier
Kimberly Meier
LCLisa W.T. Christian
Lisa W.T. Christian
MNMina Nouredanesh
Mina Nouredanesh
JTJames Tung
James Tung
DGDeborah Giaschi
Deborah Giaschi