24 April 2020 in European Spine Journal
Verified
Journal Article
Open access
PDF file
LZLaura Zengerle
Laura Zengerle
AKAnne Köhler
Anne Köhler
EDElisabeth Debout
Elisabeth Debout
CHCarsten Hackenbroch
Carsten Hackenbroch
HWHans-Joachim Wilke
Hans-Joachim Wilke
Purpose: Disc herniations are usually treated by decompression of the spinal nerves via a partial nucleotomy. As a consequence of reduced disc height (DH), reduced intradiscal pressure (IDP) and increased range of motion (ROM), accelerated degeneration may occur. Nucleus replacement implants are intended to restore those values, but are associated with the risk of extrusion. Methods: In six fresh frozen lumbar spinal segments (L2-3/L3-4/L4-5/L5-S1, age median 64.5 years (57–72), Pfirrmann grade 2–3), a prolapse was provoked through a box defect (6 × 10 mm) in the annulus. The herniated nucleus material was removed and replaced by a novel collagen-based nucleus implant. An annulus closure device sealed the defect. ROM, neutral zone (NZ) and IDP were measured in the (1) intact and (2) defect state, (3) postoperatively and (4) after cyclic loading (n = 100,000 cycles) applying pure moments (± 7.5 Nm) in flexion–extension, lateral bending and axial rotation. Additionally, the change in DH was determined. Extrusion of implants or nucleus material was evaluated macroscopically. Results: In all specimens, a prolapse could be provoked which decreased DH. Subsequent nucleotomy changed ROM/NZ and IDP considerably. Initial values could be restored by the implantation. Macroscopically, none of the implants nor nucleus material did migrate after cyclic loading. Conclusions: In this study, a prolapse followed by a nucleotomy resulted in a biomechanical destabilisation. Implantation of the nucleus replacement combined with an annulus closure restored the intact condition without showing signs of extrusion nor migration after cyclic loading. Hence, nucleus replacements could have a new chance in combination with annulus closure devices.

22 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LZLaura Zengerle
Laura Zengerle
EDElisabeth Debout
Elisabeth Debout
BKBruno Kluger
Bruno Kluger
LZLena Zöllner
Lena Zöllner
HWHans-Joachim Wilke
Hans-Joachim Wilke
Lumbar disc herniation (LDH) is the most common reason for low back pain in the working society. New regenerative approaches and novel implants are directed towards the restoration of the disc or its biomechanical properties. Aiming to investigate these new therapies under physiological conditions, in this study, a model for LDH was established by developing a new physiological in vitro test method. In 14 human lumbar motion segments, different daily-life and worst-case activities were simulated successfully by applying a physiological range of motion and axial loading in order to create physiological intradiscal pressure. An LDH could be provoked in 11 of the 14 specimens through vertical and round annular defects of different sizes. Interestingly, the defect and the LDH hardly influenced the biomechanical properties of the disc. For the investigation of regenerative approaches in further experiments, the recommendation based on the results of this study is to create an LDH in non-degenerated motion segments by the application of the new physiological in vitro test method after setting the round annular defects to a size of 4 mm in diameter.


17 March 2021 in European Spine Journal
Verified
Journal Article
Open access
PDF file
LZLaura Zengerle
Laura Zengerle
CFChristoph Fleege
Christoph Fleege
TTTheodor Di Pauli von Treuheim
Theodor Di Pauli von Treuheim
DVDaniel Vogele
Daniel Vogele
MRMichael Rauschmann
Michael Rauschmann
HWHans-Joachim Wilke
Hans-Joachim Wilke
Purpose: Prevention of implant subsidence in osteoporotic (thoraco)lumbar spines is still a major challenge in spinal surgery. In this study, a new biomechanical in vitro test method was developed to simulate patient activities in order to determine the subsidence risk of vertebral body replacements during physiologic loading conditions. Methods: The study included 12 (thoraco)lumbar (T11-L1, L2-L4) human specimens. After dorsal stabilisation and corpectomy, vertebral body replacements (VBR) with (a) round centrally located and (b) lateral end pieces with apophyseal support were implanted, equally distributed regarding segment, sex, mean BMD ((a) 64.2 mgCaHA/cm3, (b) 66.7 mgCaHA/cm3) and age ((a) 78 years, (b) 73.5 years). The specimens were then subjected to everyday activities (climbing stairs, tying shoes, lifting 20 kg) simulated by a custom-made dynamic loading simulator combining corresponding axial loads with flexion–extension and lateral bending movements. They were applied in oscillating waves at 0.5 Hz and raised every 100 cycles phase-shifted to each other by 50 N or 0.25°, respectively. The range of motion (ROM) of the specimens was determined in all three motion planes under pure moments of 3.75 Nm prior to and after implantation as well as subsequently following activities. Simultaneously, subsidence depth was quantified from fluoroscope films. A mixed model (significance level: 0.05) was established to relate subsidence risk to implant geometries and patients’ activities. Results: With this new test method, simulating everyday activities provoked clinically relevant subsidence schemes. Generally, severe everyday activities caused deeper subsidence which resulted in increased ROM. Subsidence of lateral end pieces was remarkably less pronounced which was accompanied by a smaller ROM in flexion–extension and higher motion possibilities in axial rotation (p = 0.05). Conclusion: In this study, a new biomechanical test method was developed that simulates physiologic activities to examine implant subsidence. It appears that the highest risk of subsidence occurs most when lifting heavy weights, and into the ventral part of the caudal vertebra. The results indicate that lateral end pieces may better prevent from implant subsidence because of the additional cortical support. Generally, patients that are treated with a VBR should avoid activities that create high loading on the spine.

1 September 2023 in The Spine Journal
Verified
Journal Article
Closed access
MVMorten Vogt
Morten Vogt
LZLaura Zengerle
Laura Zengerle
RJRené Jonas
René Jonas
HWHans-Joachim Wilke
Hans-Joachim Wilke

27 October 2024 in JOR SPINE
Verified
Journal Article
Open access
JJJan Ulrich Jansen
Jan Ulrich Jansen
LZLaura Zengerle
Laura Zengerle
MSMarcel Steiner
Marcel Steiner
VSVincenza Sciortino
Vincenza Sciortino
MTMarianna Tryfonidou
Marianna Tryfonidou
HWHans-Joachim Wilke
Hans-Joachim Wilke
Background: Often after large animal experiments in spinal research, the question arises—histology or biomechanics? While biomechanics are essential for informed decisions on the functionality of the therapy being studied, scientists often choose histological analysis alone. For biomechanical testing, for example, flexibility, specimens must be shipped to institutions with special testing equipment, as spine testers are complex and immobile. The specimens must usually be shipped frozen, and, thus, biological and histological investigations are not possible anymore. To allow both biomechanical and biological investigations with the same specimen and, thus, to reduce the number of required animals, the aim of the study was to develop a spine tester that can be shipped worldwide to test on‐site.Methods: The “Spine Tester TO GO” was designed consisting of a frame with three motors that initiate pure moments and rotate the specimen in three motion planes. A load cell and an optical motion tracking system controlled the applied loads and measured range of motion (ROM) and neutral zone (NZ). As a proof of concept, the new machine was validated and compared under real experimental conditions with an existing testing machine already validated employing fresh bovine tail discs CY34 (n = 10).Results: The new spine tester measured reasonable ROM and NZ from hysteresis curves, and the ROM of the two testing machines formed a high coefficient of determination R2 = 0.986. However, higher ROM results of the new testing machine might be explained by the lower friction of the air bearings, which allowed more translational motion.Conclusions: The spine tester TO GO now opens up new opportunities for on‐site flexibility tests and contributes hereby to the 3R principle by limiting the number of experimental animals needed to obtain full characterization of spine units at the macroscopic, biomechanical, biochemical, and histological level.