Vincenza Sciortino

Dr. Vincenza Sciortino

University of Palermo, Palermo, Sicilia, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2024 in Biomaterials
Verified
Journal Article
Open access
HWHans-Joachim Wilke
Hans-Joachim Wilke
VSVincenza Sciortino
Vincenza Sciortino
Disc nucleus replacement (NR) is a challenging surgical technique used as a medical treatment for early-stage disc herniation to restore disc height and the biomechanical function of a motion segment, which may reduce low back pain. The surgical procedure involves the removal and replacement of the degenerated nucleus pulposus with a substitute by accessing the annulus fibrosos via a created hole. Over the decades, nucleus replacement has been an important issue, leading to the development of different substitute alternatives. The first ideas are dated to the 1950s and since then, more than a hundred nucleus replacement concepts can be identified. There were numerous attempts and several clinical trials; however, after more than 70 years of research, no gold standard for nucleus pulposus replacement has been identified. This review aims to collect the different nucleus replacements reported in the literature, thus understanding what failed, what could be improved and what are the opportunities for the future. A systematic review of the literature was performed using a keyword-based search on PubMed, Web of Science, and Scopus databases to detect all nucleus replacements presented in the past by clinicians and engineers. Several studies were extracted from which the main nucleus replacements over the years were investigated, including the ones that received CE mark, FDA approval, or IDE approval and, also those involved in clinical trials. A total of 116 studies were included in this review. The extracted data concern the nucleus replacements proposed over the years to create a historical background as complete as possible, including their mechanical and biomechanical characterization and the clinical trials conducted over the years. Nucleus disc arthroplasty has been explored for many years. Unfortunately, even today there is still nothing safe and definitive in this surgical practice. This review provides an overview of the nucleus replacement history. A breakthrough could be the improvements in technologies for the annulus fibrous closing or sealing and the tissue engineering and medical regenerative techniques which could certainly ensure a higher NR implantation success rate in the future of this clinical treatment. It is not yet clear what is the future of this clinical practice. Only scientific research can answer the question: is the nucleus replacement still a possible clinical solution?

10 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VSVincenza Sciortino
Vincenza Sciortino
Salvatore PastaSalvatore Pasta
Salvatore Pasta
TITommaso Ingrassia
Tommaso Ingrassia
DCDonatella Cerniglia
Donatella Cerniglia
Finite element modelling of the lumbar spine is a challenging problem. Lower back pain is among the most common pathologies in the global populations, owing to which the patient may need to undergo surgery. The latter may differ in nature and complexity because of spinal disease and patient contraindications (i.e., aging). Today, the understanding of spinal column biomechanics may lead to better comprehension of the disease progression as well as to the development of innovative therapeutic strategies. Better insight into the spine’s biomechanics would certainly guarantee an evolution of current device-based treatments. In this setting, the computational approach appears to be a remarkable tool for simulating physiological and pathological spinal conditions, as well as for various aspects of surgery. Patient-specific computational simulations are constantly evolving, and require a number of validation and verification challenges to be overcome before they can achieve true and accurate results. The aim of the present schematic review is to provide an overview of the evolution and recent advances involved in computational finite element modelling (FEM) of spinal biomechanics and of the fundamental knowledge necessary to develop the best modeling approach in terms of trustworthiness and reliability.

22 August 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
VSVincenza Sciortino
Vincenza Sciortino
Salvatore PastaSalvatore Pasta
Salvatore Pasta
TITommaso Ingrassia
Tommaso Ingrassia
DCDonatella Cerniglia
Donatella Cerniglia
The spine is the load-bearing structure of human beings and may present several disorders, with low back pain the most frequent problem during human life. Signs of a spine disorder or disease vary depending on the location and type of the spine condition. Therefore, we aim to develop a probabilistic atlas of the lumbar spine segment using statistical shape modeling (SSM) and then explore the variability of spine geometry using principal component analysis (PCA). Using computed tomography (CT), the human spine was reconstructed for 24 patients with spine disorders and then the mean shape was deformed upon specific boundaries (e.g., by ±3 or ±1.5 standard deviation). Results demonstrated that principal shape modes are associated with specific morphological features of the spine segment such as Cobb’s angle, lordosis degree, spine width and height. The lumbar spine atlas here developed has evinced the potential of SSM to investigate the association between shape and morphological parameters, with the goal of developing new treatments for the management of patients with spine disorders.

22 July 2024 in Discover Applied Sciences
Verified
Journal Article
Open access
PDF file
VSVincenza Sciortino
Vincenza Sciortino
JJJan Ulrich Jansen
Jan Ulrich Jansen
DCDonatella Cerniglia
Donatella Cerniglia
TITommaso Ingrassia
Tommaso Ingrassia
HWHans-Joachim Wilke
Hans-Joachim Wilke
The intervertebral disc (IVD) is a complex biological structure that ensures the spine strength, stability, mobility, and flexibility. This is achieved due to its biphasic nature which is attained by its solid phase (annulus fibrosus) and fluid phases (nucleus pulposus). Hence, the IVD biomechanical response to long-term loads, which is critical as it affects hydration, and nutrients-water transport influencing disc height reduction, has been further explored and mathematically modelled in this paper. An in-vitro study was performed on seven human lumbar spine specimens (L4-5), to assess if the classical rheological models and Nutting's power law can model in a simple way the intermediate characteristics between solid and fluid of the IVD. Creep tests were conducted by applying a static compression load of 500 N for 15 min. A correlation analysis was done (Pearson, p < 0.05) between the model parameters and the maximum value of Disc Height Reduction, followed by a linear regression analysis. In summary, the long-term IVD mechanical behavior was modeled in a simple way, emphasizing that yet there is no mathematical certainty about this mechanical behavior. Hence, a future aim might be to develop intervertebral disc prostheses capable of replicating only the disc mechanical response, without necessarily considering the microscopic-level biological drivers. Therefore, a future goal is to fully understand and model the disc's mechanical response toward the design of new disc prostheses that would consider only the macroscopic aspect, without considering the biological aspects.

19 June 2022
Verified
Book Chapter
Closed access
PDF file
VSVincenza Sciortino
Vincenza Sciortino
DCDonatella Cerniglia
Donatella Cerniglia
SPSalvatore Pasta
Salvatore Pasta
TITommaso Ingrassia
Tommaso Ingrassia

27 October 2024 in JOR SPINE
Verified
Journal Article
Open access
JJJan Ulrich Jansen
Jan Ulrich Jansen
LZLaura Zengerle
Laura Zengerle
MSMarcel Steiner
Marcel Steiner
VSVincenza Sciortino
Vincenza Sciortino
MTMarianna Tryfonidou
Marianna Tryfonidou
HWHans-Joachim Wilke
Hans-Joachim Wilke
Background: Often after large animal experiments in spinal research, the question arises—histology or biomechanics? While biomechanics are essential for informed decisions on the functionality of the therapy being studied, scientists often choose histological analysis alone. For biomechanical testing, for example, flexibility, specimens must be shipped to institutions with special testing equipment, as spine testers are complex and immobile. The specimens must usually be shipped frozen, and, thus, biological and histological investigations are not possible anymore. To allow both biomechanical and biological investigations with the same specimen and, thus, to reduce the number of required animals, the aim of the study was to develop a spine tester that can be shipped worldwide to test on‐site.Methods: The “Spine Tester TO GO” was designed consisting of a frame with three motors that initiate pure moments and rotate the specimen in three motion planes. A load cell and an optical motion tracking system controlled the applied loads and measured range of motion (ROM) and neutral zone (NZ). As a proof of concept, the new machine was validated and compared under real experimental conditions with an existing testing machine already validated employing fresh bovine tail discs CY34 (n = 10).Results: The new spine tester measured reasonable ROM and NZ from hysteresis curves, and the ROM of the two testing machines formed a high coefficient of determination R2 = 0.986. However, higher ROM results of the new testing machine might be explained by the lower friction of the air bearings, which allowed more translational motion.Conclusions: The spine tester TO GO now opens up new opportunities for on‐site flexibility tests and contributes hereby to the 3R principle by limiting the number of experimental animals needed to obtain full characterization of spine units at the macroscopic, biomechanical, biochemical, and histological level.