Peter Aaen

Dr. Peter Aaen

Department of Electrical Engineering, Colorado School of Mines, 1500 Illinois St., Golden, CO 80401, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 March 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JCJerome Cheron
Jerome Cheron
NMNicholas C. Miller
Nicholas C. Miller
ACAntonio Crespo
Antonio Crespo
DWDylan F. Williams
Dylan F. Williams
RJRob D. Jones
Rob D. Jones
AFAri D. Feldman
Ari D. Feldman
We evaluate the accuracy of small-signal on-wafer device characterization in the sub-THz frequency range when employing conventional and advanced calibration methods with state-of-the-art design of on-chip standards. We report that major discrepancies resulting from an interlaboratory comparison experiment are mainly attributed to the influence of microwave probes. When performing conventional multiline thru-reflect-line (mTRL) calibrations with six different models of probe from 140 to 325 GHz, we observe significant variations in the measured scattering-parameters (S-parameters) and show that probes made by various manufacturers induce disparate crosstalk responses that vary between -70 and -15 dB on open–open standards. After applying a crosstalk correction approach as a second-tier calibration, we obtain significantly better agreement between the RF performance of the same heterojunction bipolar transistor (HBT) measured with two different probe models. While the difference between the maximum stable gain (MSG) reaches 1.8 dB at 210 GHz after applying a conventional mTRL calibration, we reduce the error to ~0.5 dB after crosstalk correction. This study shows that crosstalk correction methods must be implemented in the sub-THz frequency range to accurately estimate the RF performance of active devices and circuits.

9 April 2018 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JUJonas Urbonas
Jonas Urbonas
KKKevin Kim
Kevin Kim
FVFrederik Vanaverbeke
Frederik Vanaverbeke
Peter AaenPeter Aaen
Peter Aaen
In this paper, a new combined electro-optic (EO) and pulsed nonlinear vector network analyzer-based (NVNA) load-pull measurement system for distributed multiharmonic electric field (E-field) measurements is presented. The system uses an external EO probe to measure cross-frequency phase-coherent multiharmonic vector E-fields with an 8-μm spatial resolution and 20 MHz-20 GHz bandwidth. We demonstrate the performance of the distributed phase-coherent E-field measurements of Ex, Ey, and Ez components with three harmonics above a commercially available large periphery, packaged, laterally diffused metal-oxide-semiconductor transistor. The transistor was measured at 2.2 GHz under pulsed conditions with 10-μs pulse and 10% duty cycle, while outputting 55.1 dBm of power. The measured E-fields of the operating transistor are animated for the first time and reveal complex nonuniform operation at harmonic frequencies.

1 May 2010
Verified
Conference Paper
Closed access
FMFarouk Mkadem
Farouk Mkadem
MAMorsi B. Ayed
Morsi B. Ayed
SBSlim Boumaiza
Slim Boumaiza
JWJohn Wood
John Wood
Peter AaenPeter Aaen
Peter Aaen
This paper presents a novel Two Hidden Layers Artificial Neural Networks (2HLANN) model for behavioral modeling and linearization of RF Power Amplifiers (PAs). Starting with a feedback loop principle model of a PA, an appropriate neural networks structure is deduced. This structure was then optimized to form a real valued and feed-forward 2HLANN based model capable of predicting the nonlinear behavior and the memory effects of wideband PAs. The validation of the proposed model in mimicking the behavior of a Device Under Test (DUT) is carried out in terms of its accuracy in predicting the output spectrum, dynamic AM/AM and AM/PM characteristics and the normalized mean square error. In addition, the 2HLANN model was used to linearize two 250 Watt peak-envelope-power Doherty PAs (DPAs) driven with 20 MHz bandwidth signals. The linearization of these DPAs using the 2HLANN enabled attaining an output power of up to 46.8 dBm and an average efficiency of up to 47.5% coupled with an Adjacent Channel Power Ratio higher than 50 dBc. When compared to a number of previously published behavioral and DPD schemes, the 2HLANN model demonstrated an excellent modeling accuracy and linearization capability.

8 January 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CMCristian Matei
Cristian Matei
JUJonas Urbonas
Jonas Urbonas
HVHaris Votsi
Haris Votsi
DKDustin Kendig
Dustin Kendig
Peter AaenPeter Aaen
Peter Aaen
For reliability estimations, gallium nitride transistors require accurate estimations of the peak operating temperatures within the device. This paper presents a new application of thermoreflectance-based temperature measurements performed on a gallium nitride high electron mobility transistor. The submicron spatial and nanosecond temporal resolutions of the measurement system enables for the first time, the dynamic temperature measurement of a transistor operating up to 5 MHz. The GaN transistor is first biased in class-A and excited with a 1 MHz AC signal to demonstrate the dynamic temperature measurement. The transistor is then incorporated in a 20-40 V DC/DC boost converter to measure the dynamic temperature distributions across the semiconductor die operating under real loading conditions at 1 and 5 MHz switching frequencies. This technique captures the temperature variations that occur during the switching of the transistor and the recorded peak temperatures indicate an increase of up to 7.4 C compared with conventional measurement and simulation methodologies.

19 July 2024 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
RJRob D. Jones
Rob D. Jones
JCJerome Cheron
Jerome Cheron
BJBenjamin F. Jamroz
Benjamin F. Jamroz
WDWilliam R. Deal
William R. Deal
MUMiguel Urteaga
Miguel Urteaga
NONathan D. Orloff
Nathan D. Orloff
In this article we extract the capacitance of shunt and series metal-insulator-metal capacitors from on-wafer S-parameter measurements in the WR1.0 (0.75 to 1.1 THz) waveguide band. These capacitors were fabricated in two different state-of-the-art terahertz semiconductor processes and measured with two different designs of via-stitched grounded coplanar waveguide calibration kits. We investigate the measurement uncertainty of extracting a shunt capacitance in the presence of probe positioning uncertainty, calibration kit process variation, and vector network analyzer (VNA) electrical repeatability. We find that these uncertainty sources result in a large prediction interval that is 30.2% of the capacitor's value (14.9 ±4.5 fF) at 900 GHz with the uncertainty from probe positioning as the largest contributor. This is the first time that an extensive uncertainty analysis has been performed on characterizing on-wafer devices at 1 THz. We quantify the precision of current calibration techniques and measurement equipment.

3 January 2025 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
RJRob D. Jones
Rob D. Jones
JCJerome Cheron
Jerome Cheron
JDJoseph E. Diener
Joseph E. Diener
Peter AaenPeter Aaen
Peter Aaen
RCRichard A. Chamberlin
Richard A. Chamberlin
AEAtef Z. Elsherbeni
Atef Z. Elsherbeni
In this letter, we present a technique to determine efficient placement of nearby structures to the device-under-test (DUT) based on the DUT’s impedance, which is overlooked in the current layout guidelines. This technique involves sweeping both the impedance of the DUT and the spatial location of the nearby structure to create a map where the structure can be placed that would simultaneously minimize coupling to the DUT as well as the space between devices. The simulations were validated up to 110 GHz using gallium nitride (GaN) high-electron-mobility transistor (HEMT) measurements with and without a nearby line.