Jerome Cheron

Jerome Cheron

Auto-generated profile, based on publicly available information

Jerome Cheron

National Institute of Standards and Technology, Boulder, CO, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2024 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
FBFlorian Bergmann
Florian Bergmann
NJNicholas R. Jungwirth
Nicholas R. Jungwirth
BBBryan T. Bosworth
Bryan T. Bosworth
JCJerome Cheron
Jerome Cheron
CLChristian J. Long
Christian J. Long
NONathan D. Orloff
Nathan D. Orloff
Fused silica has become an interesting alternative to silicon for millimeter-wave (mmWave) applications. Unfortunately, there are a few reports on the measurement of fused silica's permittivity above 110 GHz that use electrical rather than optical methods. Given that mmWave applications use electrical circuits, additional electrical data would be useful to industry. To test the feasibility of electrical methods, we applied on-wafer techniques based on coplanar waveguide transmission lines to measure the complex permittivity of fused silica to 325 GHz. Our approach used the multiline thru-reflect-line algorithm on the scattering parameter measurements of transmission lines. Our method combined these results with dc measurements of the resistivity of the metals, simulations of the coplanar waveguide cross section, and dimensional metrology. In short, our measurements do not show significant dielectric dispersion for fused silica up to 325 GHz. The resulting complex permittivity was ϵr=3.87±0.03 and a loss tangent tanδ< 0.005 from 320 MHz to 325 GHz. To support our conclusions, we performed an uncertainty analysis considering relevant sources of uncertainty. In the broader context, these results show that fused silica is a suitable substrate for mmWave electronics where the loss tangent must be less than 0.005 up to 325 GHz.

21 March 2025 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
JCJerome Cheron
Jerome Cheron
NMNicholas C. Miller
Nicholas C. Miller
ACAntonio Crespo
Antonio Crespo
DWDylan F. Williams
Dylan F. Williams
RJRob D. Jones
Rob D. Jones
AFAri D. Feldman
Ari D. Feldman
We evaluate the accuracy of small-signal on-wafer device characterization in the sub-THz frequency range when employing conventional and advanced calibration methods with state-of-the-art design of on-chip standards. We report that major discrepancies resulting from an interlaboratory comparison experiment are mainly attributed to the influence of microwave probes. When performing conventional multiline thru-reflect-line (mTRL) calibrations with six different models of probe from 140 to 325 GHz, we observe significant variations in the measured scattering-parameters (S-parameters) and show that probes made by various manufacturers induce disparate crosstalk responses that vary between -70 and -15 dB on open–open standards. After applying a crosstalk correction approach as a second-tier calibration, we obtain significantly better agreement between the RF performance of the same heterojunction bipolar transistor (HBT) measured with two different probe models. While the difference between the maximum stable gain (MSG) reaches 1.8 dB at 210 GHz after applying a conventional mTRL calibration, we reduce the error to ~0.5 dB after crosstalk correction. This study shows that crosstalk correction methods must be implemented in the sub-THz frequency range to accurately estimate the RF performance of active devices and circuits.

14 October 2021 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
JCJerome Cheron
Jerome Cheron
DWDylan F. Williams
Dylan F. Williams
RCRichard A. Chamberlin
Richard A. Chamberlin
MUMiguel E. Urteaga
Miguel E. Urteaga
KSKassiopeia A. Smith
Kassiopeia A. Smith
AFAri D. Feldman
Ari D. Feldman
The indium phosphide (InP) 130 nm double-heterojunction bipolar transistor (DHBT) offers milliwatts of output power and high signal amplification in the lower end of the terahertz frequency band when the transistor is used in a common-base configuration. Instrumentation can directly benefit from this technology by enabling the development of novel broadband sources or synthesizers that rely on our ability to amplify the signal over enormous bandwidths. However, the design of high gain and stable amplifiers presents many obstacles and limitations as we increase the bandwidth and the carrier frequency. Here, we show that adding a series resistor at the collector terminal of the common-base transistor prevents instabilities in the terahertz monolithic integrated circuit amplifier and increases its fractional bandwidth. Adopting this technique, we report a state-of-the-art broadband common-base amplifier that exhibits a minimum small-signal gain of 18.9 dB from 325 to 477 GHz. This amplifier presents the highest fractional bandwidth and gain above 300 GHz. Our work demonstrates the feasibility of high-performance amplifiers that address the need of future terahertz electronic systems.

19 July 2024 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
RJRob D. Jones
Rob D. Jones
JCJerome Cheron
Jerome Cheron
BJBenjamin F. Jamroz
Benjamin F. Jamroz
WDWilliam R. Deal
William R. Deal
MUMiguel Urteaga
Miguel Urteaga
NONathan D. Orloff
Nathan D. Orloff
In this article we extract the capacitance of shunt and series metal-insulator-metal capacitors from on-wafer S-parameter measurements in the WR1.0 (0.75 to 1.1 THz) waveguide band. These capacitors were fabricated in two different state-of-the-art terahertz semiconductor processes and measured with two different designs of via-stitched grounded coplanar waveguide calibration kits. We investigate the measurement uncertainty of extracting a shunt capacitance in the presence of probe positioning uncertainty, calibration kit process variation, and vector network analyzer (VNA) electrical repeatability. We find that these uncertainty sources result in a large prediction interval that is 30.2% of the capacitor's value (14.9 ±4.5 fF) at 900 GHz with the uncertainty from probe positioning as the largest contributor. This is the first time that an extensive uncertainty analysis has been performed on characterizing on-wafer devices at 1 THz. We quantify the precision of current calibration techniques and measurement equipment.

18 April 2022 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
JCJerome Cheron
Jerome Cheron
DWDylan F. Williams
Dylan F. Williams
RCRichard A. Chamberlin
Richard A. Chamberlin
MUMiguel E. Urteaga
Miguel E. Urteaga
PHPaul D. Hale
Paul D. Hale
AFAri D. Feldman
Ari D. Feldman
We report a monolithic microwave integrated-circuit (MMIC) comb generator capable of producing a repetitive narrow pulse (7.1 ps pulse duration) with sharp edges (4.2 ps falling time). The circuit was designed in a 250 nm indium phosphide (InP) heterojunction bipolar transistor (HBT) technology using differential pairs. We characterized the output signal with a 110 GHz sampling oscilloscope and de-embedded the band-limited frequency spectrum of the pulse in the circuit reference plane. We measured a pulse duration of 7.1 ps and a peak amplitude of -0.333 V. In the frequency domain, the comb generator provided -48.7 dBm of output power at 110 GHz when the circuit is fed with a 1 GHz input signal.

3 January 2025 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
RJRob D. Jones
Rob D. Jones
JCJerome Cheron
Jerome Cheron
JDJoseph E. Diener
Joseph E. Diener
Peter AaenPeter Aaen
Peter Aaen
RCRichard A. Chamberlin
Richard A. Chamberlin
AEAtef Z. Elsherbeni
Atef Z. Elsherbeni
In this letter, we present a technique to determine efficient placement of nearby structures to the device-under-test (DUT) based on the DUT’s impedance, which is overlooked in the current layout guidelines. This technique involves sweeping both the impedance of the DUT and the spatial location of the nearby structure to create a map where the structure can be placed that would simultaneously minimize coupling to the DUT as well as the space between devices. The simulations were validated up to 110 GHz using gallium nitride (GaN) high-electron-mobility transistor (HEMT) measurements with and without a nearby line.