Jan Koutecký

Mr. Jan Koutecký

Designer

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
JHJosef Hlinka
Josef Hlinka
KDKamila Dostálová
Kamila Dostálová
KČKristina Čabanová
Kristina Čabanová
RMRoman Madeja
Roman Madeja
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
OUOsamu Umezawa
Osamu Umezawa
Anodization coloring of titanium tools or implants is one of the common methods for the differentiation of each application by its size or type. Commercial purity titanium grade 4 plates (50 × 20 × 0.1 mm) were tested to obtain their electrochemical and other technological properties. The coloring process was done using the potential of 15, 30, 45, 60, and 75 Volts for 5 s in 1 wt. % citric acid in demineralized water solution. Organic acids solutions generally produce better surface quality compared to inorganic acids. The contact angle of colored surfaces was measured by the sessile drop method. Electrochemical impedance spectroscopy and potentiodynamic polarization were used for the determination of selected electrochemical and corrosion parameters of the tested surfaces. It was found that the anodization process decreases corrosion potential significantly. It was also confirmed that a higher potential used for anodization results in higher polarization resistance but also a decrease in corrosion potential. The anodization process at 75 V produces surfaces with the lowest corrosion rate under 1 nm/year and the noblest corrosion potential. It was confirmed that the anodization process in citric acid does not affect titanium cytotoxicity.

19 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
MŠMilan Šír
Milan Šír
LPLeopold Pleva
Leopold Pleva
JSJiří Szeliga
Jiří Szeliga
JSJan Stránský
Jan Stránský
DSDana Stančeková
Dana Stančeková
This paper represents a multidisciplinary approach to biomechanics (medicine engineering and mathematics) in the field of collum femoris fractures, i.e., of osteosyntheses with femoral/cancellous screws with full or cannulated cross-sections. It presents our new numerical model of femoral screws together with their stochastic (probabilistic, statistical) assessment. In the first part of this article, the new simple numerical model is presented. The model, based on the theory of planar (2D) beams on an elastic foundation and on 2nd-order theory, is characterized by rapid solution. Bending and compression loadings were used for derivation of a set of three 4th-order differential equations. Two examples (i.e., a stainless-steel cannulated femoral screw and full cross-section made of Ti6Al4V material) are presented, explained, and evaluated. In the screws, the internal shearing forces, internal normal forces, internal bending moments, displacement (deflections), slopes, and mechanical stresses are calculated using deterministic and stochastic approaches. For the stochastic approach and a “fully” probabilistic reliability assessment (which is a current trend in science), the simulation-based reliability assessment method, namely, the application of the direct Monte Carlo Method, using Anthill software, is applied. The probabilities of plastic deformations in femoral screws are calculated. Future developments, which could be associated with different configurations of cancellous screws, nonlinearities, experiments, and applications, are also proposed.

9 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
DČDaniel ČEPICA
Daniel ČEPICA
Tomáš HaloTomáš Halo
Tomáš Halo
OSOndřej Skoupý
Ondřej Skoupý
LPLeopold Pleva
Leopold Pleva
POPaweł Osemlak
Paweł Osemlak
Limb asymmetry can, and often does, cause various health problems. Blount bone staples (clips) are used to correct such uneven growth. This article analyzes the performance of a biomechanical staple during bone (tibia) growth arrest. The staples considered in this study were made of 1.4441 stainless steel, the model of tibia consisted of two materials representing corticalis and spongiosis. Hooke’s law was used for modeling materials’ behaviors for finite element analysis (FEA). The maxima of stress and total staple displacement were evaluated using the finite element method and verification of the results, along with the determination of the maximum loading (growing) force that the staples are capable of withstanding, was performed experimentally. The presented method can be used to determine the safety and usability of staples for bone growth arrest. According to our results, the design of Blount staples considered in this paper is safe and suitable for orthopedic treatment.

17 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
ŠMŠárka Michenková
Šárka Michenková
LPLeopold Pleva
Leopold Pleva
JKJan Koutecký
Jan Koutecký
JFJiri Fries
Jiri Fries
Jiri PokornyJiri Pokorny
Jiri Pokorny
This article deals with a new original analytical solution of deformation, force and stress states in wood screw joints up to the limit values of pulling out/breaking the screw. The screws are under tension. The wood-to-screw interaction is effectively simplified by introducing several physical model variants using a tangential elastic non-linear foundation. The experimental verification of the proposed models using pull-out tests (i.e., pulling out screws from dry spruce wood in laboratory conditions) confirms the correctness of the proposed models of the elastic linear/non-linear foundation. The validity of the model is also analytically and experimentally verified in the biomechanical model of pulling out screws from the femur of a bovine/human cadaver, which confirms and expands the validity of newly designed screw joint models outside the timber structure area.

27 December 2021 in Metals
Verified
Journal Article
Open access
PDF file
JHJosef Hlinka
Josef Hlinka
KDKamila Dostálová
Kamila Dostálová
KDKaterina Dedkova
Katerina Dedkova
RMRoman Madeja
Roman Madeja
Karel FrydrýšekKarel Frydrýšek
Karel Frydrýšek
TDTimothy Douglas
Timothy Douglas
Nickel-based austenitic stainless steels are still common for manufacture of implants intended for acute hard tissue reinforcement or stabilization, but the risk of negative reactions due to soluble nickel-rich corrosion products must be considered seriously. Corrosion processes may even be accelerated by the evolution of microstructure caused by excessive heat during machining, etc. Therefore, this study also deals with the investigation of microstructure and microhardness changes near the threaded holes of the anterolateral distal tibial plate containing approx. 14wt.% Ni by composition. There were only insignificant changes of microhardness, grain size, or microstructure orientation found close to the area of machining. In addition, wettability measurements of surface energy demonstrated only minor differences for bulk material and areas close to machining. The cyclic potentiodynamic polarization tests were performed in isotonic physiological solution. The first cycle was used for the determination of corrosion characteristics of the implant after chemical passivation, the second cycle was used to simulate real material behavior under the condition of previous surface damage by excessive pitting corrosion occurring during previous polarization. It was found that the damaged and spontaneously repassived surface showed a three-time higher standard corrosion rate than the “as received” chemically passivated surface. One may conclude that previous surface damage may decrease the lifetime of the implant significantly and increase the amount of nickel-based corrosion products distributed into surrounding tissues.