Piotr Andrzej Turkowski

Dr. Piotr Andrzej Turkowski

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
MŁMarek Łukomski
Marek Łukomski
PSPaweł Sulik
Paweł Sulik
PRPaweł Roszkowski
Paweł Roszkowski

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
DIDaniel Izydorczyk
Daniel Izydorczyk
BSBartłomiej Sędłak
Bartłomiej Sędłak
BPBartłomiej Papis
Bartłomiej Papis
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski

7 August 2019 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
WWWojciech Węgrzyński
Wojciech Węgrzyński
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
PRPaweł Roszkowski
Paweł Roszkowski

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
MŁMarek Łukomski
Marek Łukomski
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
PRPaweł Roszkowski
Paweł Roszkowski
BPBartłomiej Papis
Bartłomiej Papis

25 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
The fire resistance of reinforced concrete (RC) beams strengthened with externally bonded reinforcement carbon fibre-reinforced polymers (EBR CFRP) depends on the load level and degree of strengthening. Design guides for this type of structure recommend strengthening limits to prevent collapse of the structure due to vandalism, damage or fire. In practice, however, it is not uncommon to exceed the proposed limits. This necessitates protection of the CFRP adhesive against high temperatures, namely glass transition temperature levels. This paper presents the results of 10 full-scale experimental fire resistance tests of reinforced concrete beams with EBR CFRP strengthening, with and without fire protection and under various load levels including full utilisation. It was demonstrated that in cases where CFRP strengthening was not needed to carry load in an accidental fire scenario, test specimens with and without it achieved the same fire resistance. It was also proven that in cases where CFRP failure influenced the failure of the entire beam, fire protection was crucial for maintaining the beam’s load-bearing capacity and its thickness had to be substantial. A fire resistance rating of over 4 h was achieved, nevertheless.

1 December 2021 in Thin-Walled Structures
Verified
Journal Article
Closed access
MMMichał Malendowski
Michał Malendowski
Wojciech SzymkućWojciech Szymkuć
Wojciech Szymkuć
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
AGAdam Glema
Adam Glema
WWWojciech Węgrzyński
Wojciech Węgrzyński