Paweł Sulik

Dr. Paweł Sulik

Instytut Techniki Budowlanej

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
PTPiotr Andrzej Turkowski
Piotr Andrzej Turkowski
MŁMarek Łukomski
Marek Łukomski
PSPaweł Sulik
Paweł Sulik
PRPaweł Roszkowski
Paweł Roszkowski

1 December 2016 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
WWWojciech Węgrzyński
Wojciech Węgrzyński
PSPaweł Sulik
Paweł Sulik

22 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof SchabowiczKrzysztof Schabowicz
Krzysztof Schabowicz
PSPaweł Sulik
Paweł Sulik
ŁZŁukasz Zawiślak
Łukasz Zawiślak
Ventilated facades are becoming an increasingly popular solution for external part of walls in the buildings. They may differ in many elements, among others things: claddings (fiber cement boards, HPL plates, large-slab ceramic tiles, ACM panels, stone cladding), types of substructures, console supports, etc. The main part that characterizes ventilated facades is the use of an air cavity between the cladding and thermal insulation. Unfortunately, in some aspects they are not yet well-standardized and tested. Above all, the requirements for the falling-off of elements from ventilated facades during a fire are not precisely defined by, among other things, the lack of clearly specified requirements and testing. This is undoubtedly a major problem, as it significantly affects the safety of evacuation during a fire emergency. For the purposes of this article, experimental tests were carried out on a large-scale facade model, with two types of external-facade cladding. The materials used as external cladding were fiber cement boards and large-slab ceramic tiles. The model of large-scale test was 3.95 m × 3.95 m, the burning gas released from the burner was used as the source of fire. The test lasted one hour. The facade model was equipped with thermocouples. The cladding materials showed different behavior during the test. Large-slab ceramic tiles seemed to be a safer form of external cladding for ventilated facades. Unfortunately, they were destroyed much faster, for about 6 min. Large-slab ceramic tiles were destroyed within the first dozen or so minutes, then their destruction did not proceed or was minimal. In the case of fiber cement boards, the destruction started from the eleventh minute and increased until the end of the test. The authors referred the results of large-scale test to testing on samples carried out by other authors. The results presented the convergence of large-scale test with samples. External claddings was equipped with additional mechanical protection. The use of additional mechanical protection to maintain external cladding elements increases their safety but does not completely eliminate the problem of the falling-off of parts of the facade. As research on fiber cement boards and large-slab ceramic tiles presented, these claddings were a major hazard due to fall-off from facade.

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
BSBartłomiej Sędłak
Bartłomiej Sędłak
PSPaweł Sulik
Paweł Sulik
DIDaniel Izydorczyk
Daniel Izydorczyk
MŁMarek Łukomski
Marek Łukomski

18 January 2016 in Applications of Structural Fire Engineering
Verified
Journal Article
Open access
PDF file
DIDaniel Izydorczyk
Daniel Izydorczyk
BSBartłomiej Sędłak
Bartłomiej Sędłak
PSPaweł Sulik
Paweł Sulik
Fire resistant door assemblies (doors) for pedestrian or industrial traffic with frame, leaf or leaves, rolled or folded curtain etc. are designed for installation in the openings of the building’s vertical internal partitions. The building and its associated equipment shall be designed and made so that in case of fire it ensures the necessary load bearing capacity of the structure for the time specified in national regulations, limitation of fire and smoke propagation within the building, limitation of fire propagation onto the adjacent buildings and evacuation of people, and it provides safety of the rescue teams. The mentioned requirements are not usually considered individually (e.g. ensuring proper evacuation is connected with the structural load bearing capacity, fire and smoke propagation within the building, and rescue team safety), therefore individual elements of buildings can play several roles during a fire.This also refers to the building elements such as doors which are usually required in terms of design and execution to ensure that in case of fire they shall, for a specific period of time prevent its development from the room or a specific zone where the fire started to other rooms or zones, allow evacuation of people by limiting heat radiation, and facilitate rescue team activities. Therefore, fire doors have a major role in the fulfillment of the rules of buildings fire safety.This paper discusses the main issues related to the fire resistance of fire doors (tests methodology and way of classification) and presents a comparison of temperature rises on unexposed surface of fire doors test specimens depending on the type of structure and side of fire exposure. Temperature rises have been compared on unexposed surface of timber, aluminum and steel single leaf doorset which have fulfill the requirements of the EI2 30 fire resistance class, in case of the fire acting from the hinge side and the side opposite to the hinges.

3 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof SchabowiczKrzysztof Schabowicz
Krzysztof Schabowicz
PSPaweł Sulik
Paweł Sulik
ŁZŁukasz Zawiślak
Łukasz Zawiślak
The paper analyzes the issue of the reduction of load capacity in fiber cement board during a fire. Fiber cement boards were put under the influence of fire by using a large-scale facade model. Such a model is a reliable source of knowledge about the behavior of facade cladding and the way fire spreads. One technical solution for external walls—a ventilated facade—is gaining popularity and is used more and more often. However, the problem of the destruction during a fire of a range of different materials used in external facade cladding is insufficiently recognized. For this study, the authors used fiber cement boards as the facade cladding. Fiber cement boards are fiber-reinforced composite materials, mainly used for facade cladding, but also used as roof cladding, drywall, drywall ceiling and floorboards. This paper analyzes the effect of fire temperatures on facade cladding using a large-scale facade model. Samples were taken from external facade cladding materials that were mounted on the model at specific locations above the combustion chamber. Subsequently, three-point bending flexural tests were performed and the effects of temperature and the integrals of temperature and time functions on the samples were evaluated. The three-point bending flexural test was chosen because it is a universal method for assessing fiber cement boards, cited in Standard EN 12467. It also allows easy reference to results in other literature.