Sam Stuart

Dr. Sam Stuart

Sport, Exercise and Rehabilitation Department, Northumbria University, Newcastle upon Tyne NE1 8ST, UK

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
RMRosie Morris
Rosie Morris
SSSamuel Stuart
Samuel Stuart
GMGrace McBarron
Grace McBarron
PFPeter Fino
Peter Fino
MMMartina Mancini
Martina Mancini
CCCarolin Curtze
Carolin Curtze
Objective : Gait provides a sensitive measurement for signs of aging and neurodegenerative conditions. Measurement of gait is transitioning from the laboratory environment to the clinic with the use of inertial measurement units, providing a simple and cost-effective assessment tool. However, such assessments first need validation against reference systems. The aim of this study was to validate the APDM Mobility Lab (ML) system (version 2) against a pressure sensor walkway in younger adults ( n = 18), older adults ( n = 18) and people with mild Parkinson’s disease ( n = 21) in the laboratory. Approach : Participants completed a two-minute walk over a pressure sensor walkway whilst wearing three sensors (strapped to the lumbar spine and both feet). Comparison of output from the systems was then performed. Main results : Overall, we identified that ML provided good to excellent agreement (ICC > 0.75) for gait velocity, stride length, stride length SD, cadence, stride time and stride time SD. Measures of double support time, single support time and swing time had moderate to poor agreement (ICC 0.213–0.725), particularly for younger adults and PD. Significance : Overall, Mobility Lab provides a valid system for gait data collection for clinical and research application.

1 July 2018 in Maturitas
Verified
Journal Article
Open access
Alan GodfreyAlan Godfrey
Alan Godfrey
VHV. Hetherington
V. Hetherington
HSHubert P. H. Shum
Hubert P. H. Shum
PBP. Bonato
P. Bonato
NLNigel Lovell
Nigel Lovell
SSS. Stuart
S. Stuart
Wearable technology (WT) has become a viable means to provide low-cost clinically sensitive data for more informed patient assessment. The benefit of WT seems obvious: small, worn discreetly in any environment, personalised data and possible integration into communication networks, facilitating remote monitoring. Yet, WT remains poorly understood and technology innovation often exceeds pragmatic clinical demand and use. Here, we provide an overview of the common challenges facing WT if it is to transition from novel gadget to an efficient, valid and reliable clinical tool for modern medicine. For simplicity, an A-Z guide is presented, focusing on key terms, aiming to provide a grounded and broad understanding of current WT developments in healthcare.

1 July 2018 in Maturitas
Verified
Journal Article
Closed access
SSSamuel Stuart
Samuel Stuart
RVRodrigo Vitorio
Rodrigo Vitorio
RMRosie Morris
Rosie Morris
DMDouglas Martini
Douglas Martini
PFPeter Fino
Peter Fino
Martina ManciniMartina Mancini
Martina Mancini

1 December 2017 in Neuroscience & Biobehavioral Reviews
Verified
Journal Article
Open access
RVRodrigo Vitorio
Rodrigo Vitorio
SSS. Stuart
S. Stuart
LRLynn Rochester
Lynn Rochester
Lisa AlcockLisa Alcock
Lisa Alcock
APAnnette Pantall
Annette Pantall
This systematic review aims to (i) evaluate functional near infrared spectroscopy (fNIRS) walking study design in young adults, older adults and people with Parkinson's disease (PD); (ii) examine signal processing techniques to reduce artefacts and physiological noise in fNIRS data; and (iii) provide evidence-based recommendations for fNIRS walking study design and signal analysis techniques. An electronic search was undertaken. The search request detailed the measurement technique, cohort and walking task. Thirty-one of an initial yield of 73 studies satisfied the criteria. Protocols and methods for removing artefacts and noise varied. Differences in fNIRS signals between studies were found in rest vs. walking, speed of walking, usual vs. complex walking and easy vs. difficult tasks. In conclusion, there are considerable technical and methodological challenges in conducting fNIRS studies during walking which can introduce inconsistencies in study findings. We provide recommendations for the construction of robust methodologies and suggest signal processing techniques implementing a theoretical framework accounting for the physiology of haemodynamic responses.

13 November 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
YCYunus Celik
Yunus Celik
SSS. Stuart
S. Stuart
Wai Lok WooWai Lok Woo
Wai Lok Woo
Alan GodfreyAlan Godfrey
Alan Godfrey
Gait assessment is an essential tool for clinical applications not only to diagnose different neurological conditions but also to monitor disease progression as it contributes to the understanding of underlying deficits. There are established methods and models for data collection and interpretation of gait assessment within different pathologies. This narrative review aims to depict the evolution of gait assessment from observation and rating scales to wearable sensors and laboratory technologies and provide limitations and possible future directions in the field of gait assessment. In this context, we first present an extensive review of current clinical outcomes and gait models. Then, we demonstrate commercially available wearable technologies with their technical capabilities along with their use in gait assessment studies for various neurological conditions. In the next sections, a descriptive knowledge for existing inertial and EMG based algorithms and a sign based guide that shows the outcomes of previous neurological gait assessment studies are presented. Finally, we state a discussion for the use of wearables in gait assessment and speculate the possible research directions by revealing the limitations and knowledge gaps in the literature.

15 October 2022 in Sports Medicine
Verified
Journal Article
Open access
PDF file
RMRachel Mason
Rachel Mason
LPLiam T. Pearson-Noseworthy
Liam T. Pearson-Noseworthy
GBGillian Barry
Gillian Barry
FYFraser Young
Fraser Young
OLOisin Lennon
Oisin Lennon
SSSamuel Stuart
Samuel Stuart
Background: Running gait assessment has traditionally been performed using subjective observation or expensive laboratory-based objective technologies, such as three-dimensional motion capture or force plates. However, recent developments in wearable devices allow for continuous monitoring and analysis of running mechanics in any environment. Objective measurement of running gait is an important (clinical) tool for injury assessment and provides measures that can be used to enhance performance.Objectives: We aimed to systematically review the available literature investigating how wearable technology is being used for running gait analysis in adults.Methods: A systematic search of the literature was conducted in the following scientific databases: PubMed, Scopus, Web of Science and SPORTDiscus. Information was extracted from each included article regarding the type of study, participants, protocol, wearable device(s), main outcomes/measures, analysis and key findings.Results: A total of 131 articles were reviewed: 56 investigated the validity of wearable technology, 22 examined the reliability and 77 focused on applied use. Most studies used inertial measurement units (n = 62) [i.e. a combination of accelerometers, gyroscopes and magnetometers in a single unit] or solely accelerometers (n = 40), with one using gyroscopes alone and 31 using pressure sensors. On average, studies used one wearable device to examine running gait. Wearable locations were distributed among the shank, shoe and waist. The mean number of participants was 26 (± 27), with an average age of 28.3 (± 7.0) years. Most studies took place indoors (n = 93), using a treadmill (n = 62), with the main aims seeking to identify running gait outcomes or investigate the effects of injury, fatigue, intrinsic factors (e.g. age, sex, morphology) or footwear on running gait outcomes. Generally, wearables were found to be valid and reliable tools for assessing running gait compared to reference standards.Conclusions: This comprehensive review highlighted that most studies that have examined running gait using wearable sensors have done so with young adult recreational runners, using one inertial measurement unit sensor, with participants running on a treadmill and reporting outcomes of ground contact time, stride length, stride frequency and tibial acceleration. Future studies are required to obtain consensus regarding terminology, protocols for testing validity and the reliability of devices and suitability of gait outcomes.Clinical Trial Registration: CRD42021235527.