Paul Peter Breen

Prof. Paul Peter Breen

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SLSally Longmore
Sally Longmore
Gough Yumu LuiGough Yumu Lui
Gough Yumu Lui
Ganesh R NaikGanesh R Naik
Ganesh R Naik
PBPaul Peter Breen
Paul Peter Breen
BJBin Jalaludin
Bin Jalaludin
GGGaetano Gargiulo
Gaetano Gargiulo
Monitoring of vital signs is critical for patient triage and management. Principal assessments of patient conditions include respiratory rate heart/pulse rate and blood oxygen saturation. However, these assessments are usually carried out with multiple sensors placed in different body locations. The aim of this paper is to identify a single location on the human anatomy whereby a single 1 cm × 1 cm non-invasive sensor could simultaneously measure heart rate (HR), blood oxygen saturation (SpO2), and respiration rate (RR), at rest and while walking. To evaluate the best anatomical location, we analytically compared eight anatomical locations for photoplethysmography (PPG) sensors simultaneously acquired by a single microprocessor at rest and while walking, with a comparison to a commercial pulse oximeter and respiration rate ground truth. Our results show that the forehead produced the most accurate results for HR and SpO2 both at rest and walking, however, it had poor RR results. The finger recorded similar results for HR and SpO2, however, it had more accurate RR results. Overall, we found the finger to be the best location for measurement of all three parameters at rest; however, no site was identified as capable of measuring all parameters while walking.

16 June 2014 in Scientific Reports
Verified
Journal Article
Open access
Yossi BuskilaYossi Buskila
Yossi Buskila
PBPaul Peter Breen
Paul Peter Breen
JTJonathan Tapson
Jonathan Tapson
ASAndre van Schaik
Andre van Schaik
MBMatthew Barton
Matthew Barton
JMJohn W. Morley
John W. Morley
The lifespan of an acute brain slice is approximately 6-12[emsp14]hours, limiting potential experimentation time. We have designed a new recovery incubation system capable of extending their lifespan to more than 36[emsp14]hours. This system controls the temperature of the incubated artificial cerebral spinal fluid (aCSF) while continuously passing the fluid through a UVC filtration system and simultaneously monitoring temperature and pH. The combination of controlled temperature and UVC filtering maintains bacteria levels in the lag phase and leads to the dramatic extension of the brain slice lifespan. Brain slice viability was validated through electrophysiological recordings as well as live/dead cell assays. This system benefits researchers by monitoring incubation conditions and standardizing this artificial environment. It further provides viable tissue for two experimental days, reducing the time spent preparing brain slices and the number of animals required for research.

11 May 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
EVElham Shabani Varaki
Elham Shabani Varaki
GGGaetano D. Gargiulo
Gaetano D. Gargiulo
SPStefania Penkala
Stefania Penkala
PBPaul Peter Breen
Paul Peter Breen
Worldwide, at least 200 million people are affected by peripheral vascular diseases (PVDs), including peripheral arterial disease (PAD), chronic venous insufficiency (CVI) and deep vein thrombosis (DVT). The high prevalence and serious consequences of PVDs have led to the development of several diagnostic tools and clinical guidelines to assist timely diagnosis and patient management. Given the increasing number of diagnostic methods available, a comprehensive review of available technologies is timely in order to understand their limitations and direct future development effort. This paper reviews the available diagnostic methods for PAD, CVI, and DVT with a focus on non-invasive modalities. Each method is critically evaluated in terms of sensitivity, specificity, accuracy, ease of use, procedure time duration, and training requirements where applicable. This review emphasizes the limitations of existing methods, highlighting a latent need for the development of new non-invasive, efficient diagnostic methods. Some newly emerging technologies are identified, in particular wearable sensors, which demonstrate considerable potential to address the need for simple, cost-effective, accurate and timely diagnosis of PVDs.

1 March 2019 in Current Biology
Verified
Journal Article
Closed access
VPVíctor Pérez-Fernández
Víctor Pérez-Fernández
Nina MilosavljevicNina Milosavljevic
Nina Milosavljevic
AAAnnette Allen
Annette Allen
KVKirstan A. Vessey
Kirstan A. Vessey
AJAndrew Jobling
Andrew Jobling
MCMorven Cameron
Morven Cameron

7 September 2022 in JMIR Mental Health
Verified
Journal Article
Open access
Gough Yumu LuiGough Yumu Lui
Gough Yumu Lui
DLDervla Loughnane
Dervla Loughnane
CPCaitlin Polley
Caitlin Polley
TJTitus Jayarathna
Titus Jayarathna
PBPaul Peter Breen
Paul Peter Breen
Background: An anticipated surge in mental health service demand related to COVID-19 has motivated the use of novel methods of care to meet demand, given workforce limitations. Digital health technologies in the form of self-tracking technology have been identified as a potential avenue, provided sufficient evidence exists to support their effectiveness in mental health contexts. Objective: This literature review aims to identify current and potential physiological or physiologically related monitoring capabilities of the Apple Watch relevant to mental health monitoring and examine the accuracy and validation status of these measures and their implications for mental health treatment. Methods: A literature review was conducted from June 2021 to July 2021 of both published and gray literature pertaining to the Apple Watch, mental health, and physiology. The literature review identified studies validating the sensor capabilities of the Apple Watch. Results: A total of 5583 paper titles were identified, with 115 (2.06%) reviewed in full. Of these 115 papers, 19 (16.5%) were related to Apple Watch validation or comparison studies. Most studies showed that the Apple Watch could measure heart rate acceptably with increased errors in case of movement. Accurate energy expenditure measurements are difficult for most wearables, with the Apple Watch generally providing the best results compared with peers, despite overestimation. Heart rate variability measurements were found to have gaps in data but were able to detect mild mental stress. Activity monitoring with step counting showed good agreement, although wheelchair use was found to be prone to overestimation and poor performance on overground tasks. Atrial fibrillation detection showed mixed results, in part because of a high inconclusive result rate, but may be useful for ongoing monitoring. No studies recorded validation of the Sleep app feature; however, accelerometer-based sleep monitoring showed high accuracy and sensitivity in detecting sleep. Conclusions: The results are encouraging regarding the application of the Apple Watch in mental health, particularly as heart rate variability is a key indicator of changes in both physical and emotional states. Particular benefits may be derived through avoidance of recall bias and collection of supporting ecological context data. However, a lack of methodologically robust and replicated evidence of user benefit, a supportive health economic analysis, and concerns about personal health information remain key factors that must be addressed to enable broader uptake.

1 March 2006 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
MMM. Clarke Moloney
M. Clarke Moloney
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
PBPaul Peter Breen
Paul Peter Breen
PBP.E. Burke
P.E. Burke
PGP.A. Grace
P.A. Grace