Caitlin Polley

Caitlin Polley


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2022 in JMIR Mental Health
Verified
Journal Article
Open access
Gough Yumu LuiGough Yumu Lui
Gough Yumu Lui
DLDervla Loughnane
Dervla Loughnane
CPCaitlin Polley
Caitlin Polley
TJTitus Jayarathna
Titus Jayarathna
PBPaul Peter Breen
Paul Peter Breen
Background: An anticipated surge in mental health service demand related to COVID-19 has motivated the use of novel methods of care to meet demand, given workforce limitations. Digital health technologies in the form of self-tracking technology have been identified as a potential avenue, provided sufficient evidence exists to support their effectiveness in mental health contexts. Objective: This literature review aims to identify current and potential physiological or physiologically related monitoring capabilities of the Apple Watch relevant to mental health monitoring and examine the accuracy and validation status of these measures and their implications for mental health treatment. Methods: A literature review was conducted from June 2021 to July 2021 of both published and gray literature pertaining to the Apple Watch, mental health, and physiology. The literature review identified studies validating the sensor capabilities of the Apple Watch. Results: A total of 5583 paper titles were identified, with 115 (2.06%) reviewed in full. Of these 115 papers, 19 (16.5%) were related to Apple Watch validation or comparison studies. Most studies showed that the Apple Watch could measure heart rate acceptably with increased errors in case of movement. Accurate energy expenditure measurements are difficult for most wearables, with the Apple Watch generally providing the best results compared with peers, despite overestimation. Heart rate variability measurements were found to have gaps in data but were able to detect mild mental stress. Activity monitoring with step counting showed good agreement, although wheelchair use was found to be prone to overestimation and poor performance on overground tasks. Atrial fibrillation detection showed mixed results, in part because of a high inconclusive result rate, but may be useful for ongoing monitoring. No studies recorded validation of the Sleep app feature; however, accelerometer-based sleep monitoring showed high accuracy and sensitivity in detecting sleep. Conclusions: The results are encouraging regarding the application of the Apple Watch in mental health, particularly as heart rate variability is a key indicator of changes in both physical and emotional states. Particular benefits may be derived through avoidance of recall bias and collection of supporting ecological context data. However, a lack of methodologically robust and replicated evidence of user benefit, a supportive health economic analysis, and concerns about personal health information remain key factors that must be addressed to enable broader uptake.

9 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
JCJessica Centracchio
Jessica Centracchio
VPVincenzo Punzo
Vincenzo Punzo
Daniele EspositoDaniele Esposito
Daniele Esposito
CPCaitlin Polley
Caitlin Polley
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
In the last few decades, a number of wearable systems for respiration monitoring that help to significantly reduce patients’ discomfort and improve the reliability of measurements have been presented. A recent research trend in biosignal acquisition is focusing on the development of monolithic sensors for monitoring multiple vital signs, which could improve the simultaneous recording of different physiological data. This study presents a performance analysis of respiration monitoring performed via forcecardiography (FCG) sensors, as compared to ECG-derived respiration (EDR) and electroresistive respiration band (ERB), which was assumed as the reference. FCG is a novel technique that records the cardiac-induced vibrations of the chest wall via specific force sensors, which provide seismocardiogram-like information, along with a novel component that seems to be related to the ventricular volume variations. Simultaneous acquisitions were obtained from seven healthy subjects at rest, during both quiet breathing and forced respiration at higher and lower rates. The raw FCG sensor signals featured a large, low-frequency, respiratory component (R-FCG), in addition to the common FCG signal. Statistical analyses of R-FCG, EDR and ERB signals showed that FCG sensors ensure a more sensitive and precise detection of respiratory acts than EDR (sensitivity: 100% vs. 95.8%, positive predictive value: 98.9% vs. 92.5%), as well as a superior accuracy and precision in interbreath interval measurement (linear regression slopes and intercepts: 0.99, 0.026 s (R2 = 0.98) vs. 0.98, 0.11 s (R2 = 0.88), Bland–Altman limits of agreement: ±0.61 s vs. ±1.5 s). This study represents a first proof of concept for the simultaneous recording of respiration signals and forcecardiograms with a single, local, small, unobtrusive, cheap sensor. This would extend the scope of FCG to monitoring multiple vital signs, as well as to the analysis of cardiorespiratory interactions, also paving the way for the continuous, long-term monitoring of patients with heart and pulmonary diseases.

13 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
Antonio FratiniAntonio Fratini
Antonio Fratini
Daniele EspositoDaniele Esposito
Daniele Esposito
Ganesh R NaikGanesh R Naik
Ganesh R Naik
CPCaitlin Polley
Caitlin Polley
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
This paper presents forcecardiography (FCG), a novel technique to measure local, cardiac-induced vibrations onto the chest wall. Since the 19th century, several techniques have been proposed to detect the mechanical vibrations caused by cardiovascular activity, the great part of which was abandoned due to the cumbersome instrumentation involved. The recent availability of unobtrusive sensors rejuvenated the research field with the most currently established technique being seismocardiography (SCG). SCG is performed by placing accelerometers onto the subject’s chest and provides information on major events of the cardiac cycle. The proposed FCG measures the cardiac-induced vibrations via force sensors placed onto the subject’s chest and provides signals with a richer informational content as compared to SCG. The two techniques were compared by analysing simultaneous recordings acquired by means of a force sensor, an accelerometer and an electrocardiograph (ECG). The force sensor and the accelerometer were rigidly fixed to each other and fastened onto the xiphoid process with a belt. The high-frequency (HF) components of FCG and SCG were highly comparable (r > 0.95) although lagged. The lag was estimated by cross-correlation and resulted in about tens of milliseconds. An additional, large, low-frequency (LF) component, associated with ventricular volume variations, was observed in FCG, while not being visible in SCG. The encouraging results of this feasibility study suggest that FCG is not only able to acquire similar information as SCG, but it also provides additional information on ventricular contraction. Further analyses are foreseen to confirm the advantages of FCG as a technique to improve the scope and significance of pervasive cardiac monitoring.

27 January 2021 in Machines
Verified
Journal Article
Open access
PDF file
Daniele EspositoDaniele Esposito
Daniele Esposito
SSSergio Savino
Sergio Savino
Chiara CosenzaChiara Cosenza
Chiara Cosenza
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
GGGaetano Gargiulo
Gaetano Gargiulo
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
The actual grip force provided by a hand prosthesis is an important parameter to evaluate its efficiency. To this end, a split cylindrical handlebar embedding a single-axis load cell was designed, 3D printed and assembled. Various measurements were made to evaluate the performances of the “Federica” hand, a simple low-cost hand prosthesis. The handlebar was placed at different angular positions with respect to the hand palm, and the experimental data were processed to estimate the overall grip force. In addition, piezoresistive force sensors were applied on selected phalanxes of the prosthesis, in order to map the distribution of the grasping forces between them. The electrical current supplied to the single servomotor that actuates all the five fingers, was monitored to estimate the force exerted on the main actuator tendon, while tendon displacement was evaluated by a rotary potentiometer fixed to the servomotor shaft. The force transfer ratio of the whole system was about 12.85 %, and the mean dissipated energy for a complete cycle of closing-opening was 106.80 Nmm, resulting lower than that of many commercial prostheses. The mean grip force of the “Federica” hand was 8.80 N, that is enough to support the user in many actions of daily life, also considering the adaptive wrapping capability of the prosthesis. On average, the middle phalanges exerted the greatest grip force (2.65 N) on the handlebar, while the distal phalanges a force of 1.66 N.

15 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CPCaitlin Polley
Caitlin Polley
TJTitus Jayarathna
Titus Jayarathna
UGUpul Gunawardana
Upul Gunawardana
Ganesh R NaikGanesh R Naik
Ganesh R Naik
Tara HamiltonTara Hamilton
Tara Hamilton
GGGaetano Gargiulo
Gaetano Gargiulo
Triage is the first interaction between a patient and a nurse/paramedic. This assessment, usually performed at Emergency departments, is a highly dynamic process and there are international grading systems that according to the patient condition initiate the patient journey. Triage requires an initial rapid assessment followed by routine checks of the patients’ vitals, including respiratory rate, temperature, and pulse rate. Ideally, these checks should be performed continuously and remotely to reduce the workload on triage nurses; optimizing tools and monitoring systems can be introduced and include a wearable patient monitoring system that is not at the expense of the patient’s comfort and can be remotely monitored through wireless connectivity. In this study, we assessed the suitability of a small ceramic piezoelectric disk submerged in a skin-safe silicone dome that enhances contact with skin, to detect wirelessly both respiration and cardiac events at several positions on the human body. For the purposes of this evaluation, we fitted the sensor with a respiratory belt as well as a single lead ECG, all acquired simultaneously. To complete Triage parameter collection, we also included a medical-grade contact thermometer. Performances of cardiac and respiratory events detection were assessed. The instantaneous heart and respiratory rates provided by the proposed sensor, the ECG and the respiratory belt were compared via statistical analyses. In all considered sensor positions, very high performances were achieved for the detection of both cardiac and respiratory events, except for the wrist, which provided lower performances for respiratory rates. These promising yet preliminary results suggest the proposed wireless sensor could be used as a wearable, hands-free monitoring device for triage assessment within emergency departments. Further tests are foreseen to assess sensor performances in real operating environments.

1 November 2019
Verified
Conference Paper
Closed access
CPCaitlin Polley
Caitlin Polley
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
PBPaolo Bifulco
Paolo Bifulco
Daniele EspositoDaniele Esposito
Daniele Esposito
Ganesh R NaikGanesh R Naik
Ganesh R Naik
GGGaetano Gargiulo
Gaetano Gargiulo
Traditional stethoscopes have remained virtually unchanged for nearly 200 years and remain the primary examination tool for all medical practitioners. While their use is prominent, their single user design and susceptibility to noise distortions can result in loss of critical diagnostic information. With the rise of cardiovascular disease worldwide, a shift for more effective tools in practitioner's repertoire is needed to ensure accurate and quick diagnosis is made. This can be achieved with the implementation of an Electronic Stethoscope using a single low-cost front-end sensing unit with integrated pre-amplifier and filter to rival some commercially available sensors that are high cost. A piezoelectric sensor was used cast in a two different domed silicone enclosure to protect the unit and provide better acoustical transmittance of the sounds generated from the human body. The results collected form the carotid artery showed that a simple, yet effective electronic design with final cost of %18.20 AUD - could produce good quality signals of both systole and diastole which could then be processed in MATLAB to increase bodily sounds volume and enable use of this tool in the field. This paper presents the preliminary work limited to the analogue front-end.