As an onsite condition monitoring method, infrared inspection can help to discover and analyze abnormal temperature increases in power equipment. To improve the efficiency of onsite diagnosis of insulators in substations, this paper proposes an automatic diagnosis method using instance segmentation and temperature analysis of infrared insulator images. To develop this method, thousands of infrared images from field inspection databases were collected to establish an annotated data set of insulator images. With the aid of Mask R-CNN it was possible to extract multiple insulators automatically in the infrared images. Transfer learning as well as the dynamic learning rate algorithm were then employed to realize the training process of Mask R-CNN with the annotated image data set. The result of the testing experiment showed that the mAP of the model is 0.77 and the FPS is 5.07, which indicated great identification accuracy and computing speed of the proposed model. Next, function fitting was realized to extract the temperature distribution of each insulator. Finally, to evaluate the condition of each insulator, rules, which are based on the related standards, were established using machine language. This is the first time that the machine could independently realize fault analysis of multiple insulators in the infrared images, which is a great attempt to adapt the development of the Internet of Things and the tendency of predictive maintenance. Moreover, because of the universality of the model algorithm used, automatic infrared fault diagnosis for other power equipment could also be performed in a similar manner, which has significant potential applicability in the area of power equipment diagnosis.
22 May 2019 in IEEE Transactions on Power Delivery
Insulation condition monitoring is essential for the safety of our distribution power gird. However, the traditional monitoring solution is hardly applied due to the concerns arise from natures of distribution grid, such as complex feeder networks, massive operation site and high economic benefit. In this paper, a wireless sensing network based on IoT technology is demonstrated for insulation condition perception. First of all, the general framework of the wireless sensing network is designed with considerations on extendibility and accessibility. Next, it goes into detail about the technical requirements of the essential units of the sensing network including sensor node, power management and data communication. With this concept, two practical cases of IoT-based partial discharge sensing networks realized on the switchgear cabinet and power cable are presented with details involving the design of TEV and HFCT sensor nodes, the energy consumption, Lora/NB-IoT-based network structures and data usage strategies. This IoT-based insulation condition monitoring is proven to be applicable for the distribution grid and expected to be references for more possible IoT applications.
25 March 2022 in IEEE Transactions on Instrumentation and Measurement
In this article, a hypersensitive multispectral partial discharge (PD) optical sensor array was developed, by which the optical pulses in seven independent bands can be acquired simultaneously. By using this sensor array, the multispectral pulses for three typical PDs in gas insulated system were obtained experimentally and analyzed with phase-based (phase-resolved) and nonphase-based (spectral-ratio-based) multispectral characteristics, respectively. It indicates that the multispectral characteristics produced by a specific discharge defect provide unique spectral signatures in discharge mode as well as stage evolution. Based on the intrinsic relationship between the discharge feature and optical emission spectrum, we adopted the classification algorithms and spectral-ratio-reserved multispectral characteristics to implement pattern recognition as well as assessment on the three typical PDs, which obtained the hit ratios exceeding 91%. In principle, such detection approach also supports the phase-independent PD diagnosis especially for dc power equipment.
Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.
Sulfur hexafluoride (SF6) gas-insulated electrical equipment is widely used in high-voltage (HV) and extra-high-voltage (EHV) power systems. Partial discharge (PD) and local heating can occur in the electrical equipment because of insulation faults, which results in SF6 decomposition and ultimately generates several types of decomposition products. These SF6 decomposition products can be qualitatively and quantitatively detected with relevant detection methods, and such detection contributes to diagnosing the internal faults and evaluating the security risks of the equipment. At present, multiple detection methods exist for analyzing the SF6 decomposition products, and electrochemical sensing (ES) and infrared (IR) spectroscopy are well suited for application in online detection. In this study, the combination of ES with IR spectroscopy is used to detect SF6 gas decomposition. First, the characteristics of these two detection methods are studied, and the data analysis matrix is established. Then, a qualitative and quantitative analysis ES-IR model is established by adopting a two-step approach. A SF6 decomposition detector is designed and manufactured by combining an electrochemical sensor and IR spectroscopy technology. The detector is used to detect SF6 gas decomposition and is verified to reliably and accurately detect the gas components and concentrations.