Abdelrahman Alshehawy

Dr. Abdelrahman Alshehawy

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in Processes
Verified
Journal Article
Open access
PDF file
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
MGMohsen Ghali
Mohsen Ghali
Matti LehtonenMatti Lehtonen
Matti Lehtonen
Mohamed M. F. DarwishMohamed M. F. Darwish
Mohamed M. F. Darwish
Condition assessment of insulating oil is crucial for the reliable long-term operation of power equipment, especially power transformers. Under thermal aging, critical degradation in oil properties, including chemical, physical, and dielectric properties, occurs due to the generation of aging byproducts. Ultraviolet-visible (UV-Vis) spectroscopy was recently proposed for the condition assessment of mineral oil. However, this absorption technique may involve all electronic states of the investigated material which typically yield a broad spectrum, and thus cannot precisely reflect the electronic structure of aged oil samples. It also cannot be implemented as an online sensor of oil degradation. In this paper, photoluminescence (PL) spectroscopy is introduced, for the first time, for effective condition assessment of insulating oil. The PL technique involves emission processes that only occur between a narrow band of electronic states that are occupied by thermalized electrons and consequently yields a spectrum that is much narrower than that of the absorption spectrum. Aged oil samples with different aging extents were prepared in the laboratory using accelerated aging tests at 120 °C, under which 1 day of laboratory aging is equivalent to approximately 1 year of aging in the field. These aged samples were then tested using PL spectroscopy with a wavelength ranging from 150 nm to 1500 nm. Two main parameters were evaluated for quantitative analysis of PL spectra: The full width at half-maximum and the enclosed area under the PL spectra. These parameters were correlated to the aging extent. In conjunction with PL spectroscopy, the aged oil samples were tested for the dielectric dissipation factor as an indication of the number of aging byproducts. Interestingly, we find a correlation between the PL spectra and the dielectric dissipation factor. The results of PL spectroscopy were compared to those of UV-Vis spectroscopy for the same samples and the parameters extracted from PL spectra were compared to the aging b-products extracted from UV-Vis spectra. Finally, the corresponding physical mechanisms were discussed considering the obtained results and the spectral shift for each spectrum. It was proved that PL spectroscopy is a promising technique for the condition assessment of insulating oil when compared to conventional transformer oil assessment measuring techniques and even to other optical absorption techniques.

1 December 2016
Verified
Conference Paper
Closed access
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
ARAbdallah Rezk
Abdallah Rezk
MGMohsen Ghali
Mohsen Ghali
Aged transformer oil can be evaluated by conventional tests to assess the degradation in electrical, chemical and physical properties. However, proper evaluation requires expensive equipment, expertise and time for sampling and testing. UV-Vis spectroscopy is a nondestructive technique that can be conducted on-line with a lower cost and a simple manner. This study aims to investigate the impact of thermal aging on the UV-Vis spectra and the dielectric properties of aged transformer oil in order to correlate between them for the sake of condition assessment of aged transformer oil using UV-Vis spectroscopy. In this regard, oil samples were thermally degraded by accelerated aging experiment in laboratory. Then, these samples were tested for breakdown voltage and dielectric dissipation factor. Also, water content was measured due to its influence on the dielectric properties. In addition, the samples were tested using UV-Vis spectrophotometer to obtain UV-Vis spectra and decomposition by-products. The results were investigated considering the effect of aging duration and correlating the decomposition by-products with dielectric properties. The results indicate that UV-Vis spectra can reflect the degradation in aged transformer oil.

1 June 2017
Verified
Conference Paper
Closed access
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
MGMohsen Ghali
Mohsen Ghali
ARAbdallah Rezk
Abdallah Rezk
Recently, optical spectroscopy techniques have been proposed for condition assessment of transformer oil. They can be conducted online using less expensive equipment than other traditionally used techniques. In this paper, aged transformer oil samples were collected from different field transformers, and then evaluated by optical spectroscopy techniques. These techniques included UV-Vis, emission and FT-IR spectroscopy. Also, the dielectric properties of the oil samples were evaluated by breakdown voltage test and dielectric dissipation factor test. In addition, water content test was performed due to its influence on dielectric properties. The obtained optical spectra have shown remarkable results for different aged oil samples. We find that the level of decomposition by-products can be evaluated from the obtained UV-Vis spectra. The results authenticated the good correlation either between optical spectra features and aging period or between optical spectra features and dielectric losses.

1 October 2016
Verified
Conference Paper
Closed access
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
MGMohsen Ghali
Mohsen Ghali
Transformer oil achieves the role of electrical insulation and cooling in power transformers. The oil properties are greatly degraded due to thermal and electrical stresses occurring during the operation of a transformer. To overcome sudden failures of transformers, condition monitoring of insulating oil is essential. Modern optical spectroscopy techniques are reliable, on-line, simple and inexpensive tests which show significant information that can be useful in assessing the degradation of transformer oil. This paper aims to use optical spectroscopy techniques, achieved by spectrophotometers, for assessing the condition of aged transformer oil. In this regard, UV-VIS spectroscopy and FTIR spectroscopy were used to test aged oil samples. The samples were aged using accelerated aging test at 120 °C in an oven to simulate actual aging in the field. Through using UV-VIS spectroscopy, a physical investigation on the condition of the aged oil samples could be conducted. In addition, dissolved decay products generated in the aged oil could be assessed. On the other hand, through using FTIR spectroscopy, the functional groups in the samples could be identified. Correlating the optical spectra with the aging duration validates the ability of optical spectroscopy techniques in the accurate condition assessment of aged transformer oil.

13 January 2025 in Electrical Materials and Applications
Verified
Journal Article
Open access
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
SMShanika Matharage
Shanika Matharage
ZWZhongdong Wang
Zhongdong Wang
Applying environmentally friendly ester liquids in high‐voltage direct current (HVDC) converter transformers is a technological ambition that requires research on their performance under DC voltages. This paper researched ester liquid‐impregnated Kraft paper through experimentally investigating space charges and dielectric properties under HVDC fields. The study focused mainly on the influence of cellulose degradation. Hence, Kraft papers of different degree of polymerisation impregnated with fresh ester liquid and fresh mineral oil were tested, and their space charges, electric field distortion, conductivity and permittivity were evaluated. Strong correlations were found between these parameters. Electric field distortion in fresh ester liquid‐impregnated paper (ELIP) was higher than that in fresh mineral oil‐impregnated paper (MOIP) but remained almost constant with paper‐ageing. However, electric field distortion increased noticeably in MOIP with paper‐ageing and became higher than that in ELIP. Thus, electric field distortion resulted from space charges and conductivity mismatch under new and ageing conditions must be considered in designing the insulation systems of converter transformers.

4 February 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ARAbdellatif K. Rashed
Abdellatif K. Rashed
AAAbdelrahman Alshehawy
Abdelrahman Alshehawy
Diaa-Eldin A. MansourDiaa-Eldin A. Mansour
Diaa-Eldin A. Mansour
RFRizwan A. Farade
Rizwan A. Farade
MGM. Ghali
M. Ghali
Tamer MegahedTamer Megahed
Tamer Megahed
Power transformers are critical components in power grids, whose main role is maintaining the required voltage levels throughout the grid. Thus, continuous condition monitoring of their status is crucial. Otherwise, catastrophic repercussions would occur. Diagnosis and condition assessment of power transformers ensure that the power transformer operates safely without service interruption and allow to schedule preventive maintenance. Optical spectroscopy has gained considerable attention over conventional condition assessment techniques due to its simplicity, speed, accuracy, non-destructiveness approaches, and cost-effectiveness. This paper reviews various optical spectroscopy technologies applied to condition assessment and fault diagnosis of insulation systems inside power transformers to predict their quality. These techniques include ultraviolet-visible spectroscopy, photoluminescence spectroscopy, near infrared spectroscopy, and infrared spectroscopy. First, transformer insulation parameters correlated with aging are highlighted. Then, the technologies used in optical spectroscopy approach are discussed. After that, the detailed application of these technologies and possible correlation between their characteristic parameters and insulation condition are discussed. Finally, further needs for future research, development and standardization are identified.