In this study, the use of electrical resistance (ER) sensors to monitor the corrosion of Al94Cu6 alloy is assessed and compared with 2024‐T3 coupons. Under uniform corrosion, a good correlation was found between the ER sensors and mass loss on coupons. Three different chloride depositions are studied: (i) pre‐contamination with dry/wet cycles, (ii) Volvo standard accelerated corrosion test and (iii) neutral salt spray test. The obtained results show good reproducibility of the ER sensors under all tested conditions. This suggests that ER sensors more levelled the effect of localised corrosion through a large surface evaluation compared with cross‐sections. The corrosion thickness obtained with the ER sensors does not correspond to the mean depth obtained by cross‐sections. This can be explained by the distribution and size of the localised corrosion events according to a finite element model proposed. The ER method allows obtaining useful real‐time corrosion data for the understanding of the corrosion mechanisms and the development of accelerated tests. The chloride concentration, the frequency of salt application and wet/dry cycles have a strong influence on the corrosion rate of aluminium alloys.
The control of air quality in museums or storages is of fundamental interest for the conservation of historic artifacts. The present work reports an example of application of RFID sensors developed in the European project SensMat and dedicated to this issue. The sensors are based on the variation of property of an RFID tag coupled with a sensitive silver thin film exposed to the environment. As it will be described in the paper, such low-cost sensors are interrogated by a commercial reader and provide the environmental corrosivity index and thus the presence of pollutants. The selected case study concerns the monitoring of pollution by H2S in a building dedicated to conservation and restoration of archeological and historical woods. The ability of sensors to map spatially the corrosivity within buildings is highlighted.
The control of air quality in museums or storages is of fundamental interest for the conservation of historic artifacts. The present work reports an example of application of RFID sensors developed in the European project SensMat and dedicated to this issue. The sensors are based on the varia-tion of property of an RFID tag coupled to a sensitive silver thin film exposed to the environment. As it will be described in the paper, such low cost sensors are interrogated by a commercial reader and provide the environmental corrosivity index and thus the presence of pollutants. The selected case study concerns the monitoring of pollution by H2S in a building dedicated to conservation and restoration of archeological and historical woods. The ability of sensors to map spatially the corrosivity within buildings is highlighted.
Electrical resistance (ER)‐based corrosion sensors, developed in the context of the Cigeo project (Industrial Centre for Geological Disposal) related to high‐level radioactive waste deep geological disposal, have been qualified under irradiation conditions. The ER sensors used in this study, made of thin (25 µm) AISI 1010 carbon steel, were exposed to atmospheric conditions under three different radiation doses of 0.25, 0.50 and 1.00 MGy using a 60 Co radionuclide source of γ‐rays. The results indicate that the developed ER sensors remained reliable even under strong ionizing conditions with no significant reduction of the ER sensor measurement properties. While low relative humidity levels were recorded, ranging between 45% and 60%, the results provided by the ER sensors showed that conditions created under irradiation led to the corrosion of the AISI 1010 carbon steel with a potential dose effect on the carbon steel corrosion rate.