BARANILINGESAN Irusappan

Dr. BARANILINGESAN Irusappan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
NJN. Yogambal Jayalakshmi
N. Yogambal Jayalakshmi
RSR. Shankar
R. Shankar
Umashankar SubramaniamUmashankar Subramaniam
Umashankar Subramaniam
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
Alagar KarthickAlagar Karthick
Alagar Karthick
Aritra GhoshAritra Ghosh
Aritra Ghosh
Solar irradiance forecasting is an inevitable and most significant process in grid-connected photovoltaic systems. Solar power is highly non-linear, and thus to manage the grid operation efficiently, with irradiance forecasting for various timescales, such as an hour ahead, a day ahead, and a week ahead, strategies are developed and analysed in this article. However, the single time scale model can perform better for that specific time scale but cannot be employed for other time scale forecasting. Moreover, the data consideration for single time scale forecasting is limited. In this work, a multi-time scale model for solar irradiance forecasting is proposed based on the multi-task learning algorithm. An effective resource sharing scheme between each task is presented. The proposed multi-task learning algorithm is implemented with a long short-term memory (LSTM) neural network model and the performance is investigated for various time scale forecasting. The hyperparameter estimation of the proposed LSTM model is made by a hybrid chicken swarm optimizer based on combining the best features of both the chicken swarm optimization algorithm (CSO) and grey wolf optimization (GWO) algorithm. The proposed model is validated, comparing existing methodologies for single timescale forecasting, and the proposed strategy demonstrated highly consistent performance for all time scale forecasting with improved metric results.

1 July 2021 in Solid State Communications
Verified
Journal Article
Closed access
CPC. Pazhanimuthu
C. Pazhanimuthu
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
Alagar KarthickAlagar Karthick
Alagar Karthick

1 January 2022
Verified
Conference Paper
Closed access
PDF file
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
VKV. Kathirodhayan
V. Kathirodhayan
PHP. Hariharan
P. Hariharan

14 July 2025 in International Journal of Control, Automation, and Systems
Verified
Journal Article
Closed access
PDF file
KSK. B. Sri Sathya
K. B. Sri Sathya
KSKandasamy Sellamuthu
Kandasamy Sellamuthu
PVP. Vasundradevi
P. Vasundradevi
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
NNN. Nandhini
N. Nandhini

30 September 2026 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
PDF file
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
MKMallula Vijaya Krishna
Mallula Vijaya Krishna
HSHareesh seeta
Hareesh seeta
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
Intelligent condition monitoring of Direct Current (DC) to DC converters requires fault detection that is accurate, reproducible and early enough to act before conventional protection trips. This paper presents a Random Forest (RF) framework that fuses output-voltage, inductor-current and heatsink-temperature measurements of a 48 V/10 A synchronous buck converter (96 V input, 20 kHz switching, cascaded PI control). A fully specified averaged-model simulation with sensor models (10 kHz sampling) and per-run component tolerances generates 200 labelled runs (40 per class, 60 s each; 59,000 windows of 0.2 s) covering normal operation, overcurrent (13.8–15.2 A), overvoltage (55.5–59.0 V), overtemperature caused by cooling degradation, and a combined severe fault. Ten features are extracted per window, including ripple factors, ripple Total Harmonic Distortion (THD), temperature slope and a thermal-model residual. A five-class RF (128 trees, maximum depth 14) tuned by Bayesian optimisation under run-wise cross-validation achieves 97.9% accuracy and 98.1% macro-F1 on 60 independent test runs (16,843 windows), and 97.7 ± 1.4% accuracy in repeated group 5-fold cross-validation. A tuned support vector machine attains higher in-distribution accuracy (99.5%), whereas RF gives the highest mean accuracy (98.0%) under six unseen operating conditions. Fusing electrical and thermal features raises accuracy from 70.2% (electrical only) and 75.4% (thermal only) to 97.9%. With a three-window alarm rule, all 48 test faults are flagged before the conventional trip threshold is crossed, with mean lead times of 3.9 s (overcurrent), 7.5 s (overvoltage), 26.5 s (overtemperature) and 2.5 s (severe fault). A classifier-weighted Fault Severity Index (FSI) rises from 0.04 in normal operation to 2.62 under severe fault, providing a quantitative severity ranking.