Parimalasundar Ezhilvannan

Dr. Parimalasundar Ezhilvannan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2025 in Defence Science Journal
Verified
Journal Article
Open access
PDF file
SKSuresh K.
Suresh K.
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
This paper introduces a novel pulse frequency modulation (PFM)-driven universal step-down converter tailored for high-efficiency, low-power IoT applications, with a strong emphasis on minimizing voltage ripple. The architecture incorporates a flexible Comparator in place of conventional static designs, thereby enhancing voltage gain, accelerating decision speed, and reducing dynamic power dissipation. A flexible OFF-control strategy is further employed to selectively deactivate auxiliary control circuits, significantly mitigating controller-induced losses. Fabricated in 0.32-µm CMOS technology, the converter achieves output ripple voltages consistently within 2.1–2.9 mV, while attaining a peak power efficiency of 95 %. These results underscore the converter’s robustness and suitability for resource-constrained IoT environments. This innovative approach highlighting the potential of PFM-based control in addressing challenges associated with voltage regulation, power efficiency, and ripple reduction, making it an ideal solution for next-generation power management systems requiring compact, efficient, and reliable converters. This method demonstrates the effectiveness of Pulse Frequency Modulation (PFM)-based control in overcoming voltage regulation challenges, enhancing power efficiency, and minimizing output ripple. Its ability to deliver compact, reliable, and energy-efficient performance positions it as a highly suitable solution for next-generation power management systems in modern electronic defence applications.

11 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
GKG KIRAN KUMAR
G KIRAN KUMAR
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
DEDevaraj Elangovan
Devaraj Elangovan
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
FRANCESCO IANNUZZOFRANCESCO IANNUZZO
FRANCESCO IANNUZZO
JHJens Bo Holm-Nielsen
Jens Bo Holm-Nielsen
In recent times, multilevel inverters are used as a high priority in many sizeable industrial drive applications. However, the reliability and performance of multilevel inverters are affected by the failure of power electronic switches. In this paper, the failure of power electronic switches of multilevel inverters is identified with the help of a high-performance diagnostic system during the open switch and low condition. Experimental and simulation analysis was carried out on five levels cascaded h-bridge multilevel inverter, and its output voltage waveforms were synthesized at different switch fault cases and different modulation index parameter values. Salient frequency-domain features of the output voltage signal were extracted using a Fast Fourier Transform decomposition technique. The real-time work of the proposed fault diagnostic system was implemented through the LabVIEW software. The Offline Artificial neural network was trained using the MATLAB software, and the overall system parameters were transferred to the LabVIEW real-time system. With the proposed method, it is possible to identify the individual faulty switch of multilevel inverters successfully.

30 June 2023 in International Journal of Electrical and Electronics Engineering
Verified
Journal Article
Open access
PDF file
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
SJS. Jayakumar
S. Jayakumar
TDT. Devaraju
T. Devaraju
CSChandrika V S
Chandrika V S
This paper describes the design and analysis of a proposed seven-level multilevel inverter for integrating renewable energy sources into the power grid. Power conversion options that are efficient and trustworthy are crucial for effortless integration and effective use of renewable energy systems, which are becoming increasingly prevalent. Compared to conventional two-level inverters, multilevel inverters have several benefits, including less harmonic distortion, less voltage stress on the power devices, and improved power quality. A cascaded H-bridge structure combines the advantages of a modified phase-shifted pulse width modulation (PWM) control scheme in the proposed seven-level multilevel inverter topology. The design parameters and switching angles are optimised to achieve the highest power efficiency and least harmonic distortion. The proposed inverter is subjected to a thorough analysis, considering power losses, total harmonic distortion, and voltage waveforms. The proposed inverter's performance metrics and simulation results contrast the current multilevel inverter topologies. The proposed seven-level multilevel inverter offers better voltage quality, less total harmonic distortion, and lower power losses when compared to other existing topologies, according to simulation results. The suggested inverter also offers a superior output voltage waveform appropriate for the grid integration of renewable energy sources. The analysis and assessment provided in this paper confirm the viability and efficacy of the seven-level multilevel inverter suggested for integrating renewable energy, thereby advancing conversion technologies in the application of energy-efficient systems.

12 November 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PRP. Rajakumar
P. Rajakumar
PBP. M. Balasubramaniam
P. M. Balasubramaniam
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
KSK. Suresh
K. Suresh
Aravind Pitchai VenkataramanAravind Pitchai Venkataraman
Aravind Pitchai Venkataraman
This paper presents an effective metaheuristic framework using the Osprey Optimization Algorithm (OOA) for the simultaneous allocation of distributed generation (DG) units and capacitor banks (CB) in radial distribution systems (RDS). The method optimizes the locations and sizing for DG units and CB to minimize active power losses (APL), to reduce voltage deviation (VD), and to enhance voltage stability. The performance of the proposed approach is tested on IEEE 69-bus and 118-bus benchmark RDSs and the real-time Tala Egyptian RDS. The OOA achieved superior results compared to popular heuristic algorithms such as antlion optimizer (ALO), hunter-prey optimizer (HPO), and whale optimizer algorithm (WOA). Specifically, for three units of DG and single capacitor integration in the 69-bus system, OOA reduced the total APL by 75.1%, lowered the total voltage deviation (TVD) by 1.4835 p.u., and improved the total voltage stability index (TVSI) by 3.0229. With optimal assimilation of three units of DG and capacitors each, APL reduction, TVD minimization, and TVSI improvement further extended to 79.9%, 1.5013 p.u., and 2.2787, respectively. Furthermore, OOA validation on a variable-load 69-bus RDS and the real 37-bus Tala Egyptian RDS demonstrated consistent and superior performance, showcasing its robustness. Statistical analyses also confirm OOA’s efficiency and ability to solve DG planning in the distribution networks.

30 September 2026 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
PDF file
BIBARANILINGESAN Irusappan
BARANILINGESAN Irusappan
MKMallula Vijaya Krishna
Mallula Vijaya Krishna
HSHareesh seeta
Hareesh seeta
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
Intelligent condition monitoring of Direct Current (DC) to DC converters requires fault detection that is accurate, reproducible and early enough to act before conventional protection trips. This paper presents a Random Forest (RF) framework that fuses output-voltage, inductor-current and heatsink-temperature measurements of a 48 V/10 A synchronous buck converter (96 V input, 20 kHz switching, cascaded PI control). A fully specified averaged-model simulation with sensor models (10 kHz sampling) and per-run component tolerances generates 200 labelled runs (40 per class, 60 s each; 59,000 windows of 0.2 s) covering normal operation, overcurrent (13.8–15.2 A), overvoltage (55.5–59.0 V), overtemperature caused by cooling degradation, and a combined severe fault. Ten features are extracted per window, including ripple factors, ripple Total Harmonic Distortion (THD), temperature slope and a thermal-model residual. A five-class RF (128 trees, maximum depth 14) tuned by Bayesian optimisation under run-wise cross-validation achieves 97.9% accuracy and 98.1% macro-F1 on 60 independent test runs (16,843 windows), and 97.7 ± 1.4% accuracy in repeated group 5-fold cross-validation. A tuned support vector machine attains higher in-distribution accuracy (99.5%), whereas RF gives the highest mean accuracy (98.0%) under six unseen operating conditions. Fusing electrical and thermal features raises accuracy from 70.2% (electrical only) and 75.4% (thermal only) to 97.9%. With a three-window alarm rule, all 48 test faults are flagged before the conventional trip threshold is crossed, with mean lead times of 3.9 s (overcurrent), 7.5 s (overvoltage), 26.5 s (overtemperature) and 2.5 s (severe fault). A classifier-weighted Fault Severity Index (FSI) rises from 0.04 in normal operation to 2.62 under severe fault, providing a quantitative severity ranking.

31 May 2025 in International Journal of Electrical and Electronics Engineering
Verified
Journal Article
Open access
PDF file
PEParimalasundar Ezhilvannan
Parimalasundar Ezhilvannan
SMS. Muthukaruppasamy
S. Muthukaruppasamy
SSSendil Kumar S
Sendil Kumar S
DRDharmaprakash R
Dharmaprakash R
JSJayakumar S
Jayakumar S
NTNageswara Prasad T
Nageswara Prasad T
Multilevel Inverters (MLIs) are crucial in photovoltaic (PV) systems since they enhance efficiency, reduce Total Harmonic Distortion (THD), and minimize switching losses. There is a comparison between the Cascaded H-Bridge (CHB), the Flying Capacitor (FC), the Neutral Point Clamped (NPC), and a modified MLI design, which is shown in this research. The redesigned inverter, which consists of three DC sources, four diodes, and seven switches, achieves an efficiency of 98%, which is higher than the CHB (96%), FC (95%), and NPC (96%). The performance of the inverter is validated using simulations conducted in MATLAB/Simulink, which include a wide range of modulation indices and load conditions. While the modified topology reduces total power loss to 180W, it produces 308.75V with a THD of 7.3% at m=0.95. In contrast, cascaded H-bridges produce 200W and neutral point clamped MLIs produce 220W. A power factor of 0.93 and an efficiency of 93% are achieved by the system when it is subjected to conditions of resistive-inductive load interaction. In comparison to conventional topologies, the MLI that has been proposed reduces switching and conduction losses by around fifteen percent, which guarantees greater voltage balancing and fault tolerance via its implementation. In addition, the inverter functions in a manner that guarantees consistent operation via the use of a simplified control mechanism, which makes it an economical choice for grid-connected solar applications. Based on the findings of the research, it has been established that the redesigned design has increased power quality by a substantial amount, decreased harmonic distortions, and enhanced system reliability, therefore establishing it as a viable alternative for the future generation of renewable energy systems.