Maryia Drobysh

Ms. Maryia Drobysh

Center for Physical Sciences and Technology (FTMC)
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
RVRoman Viter
Roman Viter
Chien-Fu ChenChien-Fu Chen
Chien-Fu Chen
UPURTE PRENTICE
URTE PRENTICE
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
Monitoring and tracking infection is required in order to reduce the spread of the coronavirus disease 2019 (COVID-19), induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To achieve this goal, the development and deployment of quick, accurate, and sensitive diagnostic methods are necessary. The determination of the SARS-CoV-2 virus is performed by biosensing devices, which vary according to detection methods and the biomarkers which are inducing/providing an analytical signal. RNA hybridisation, antigen-antibody affinity interaction, and a variety of other biological reactions are commonly used to generate analytical signals that can be precisely detected using electrochemical, electrochemiluminescence, optical, and other methodologies and transducers. Electrochemical biosensors, in particular, correspond to the current trend of bioanalytical process acceleration and simplification. Immunosensors are based on the determination of antigen-antibody interaction, which on some occasions can be determined in a label-free mode with sufficient sensitivity.

2 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
RVRoman Viter
Roman Viter
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
The coronavirus disease 2019 (COVID-19) outbreak caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was proclaimed a global pandemic in March 2020. Reducing the dissemination rate, in particular by tracking the infected people and their contacts, is the main instrument against infection spreading. Therefore, the creation and implementation of fast, reliable and responsive methods suitable for the diagnosis of COVID-19 are required. These needs can be fulfilled using affinity sensors, which differ in applied detection methods and markers that are generating analytical signals. Recently, nucleic acid hybridization, antigen-antibody interaction, and change of reactive oxygen species (ROS) level are mostly used for the generation of analytical signals, which can be accurately measured by electrochemical, optical, surface plasmon resonance, field-effect transistors, and some other methods and transducers. Electrochemical biosensors are the most consistent with the general trend towards, acceleration, and simplification of the bioanalytical process. These biosensors mostly are based on the determination of antigen-antibody interaction and are robust, sensitive, accurate, and sometimes enable label-free detection of an analyte. Along with the specification of biosensors, we also provide a brief overview of generally used testing techniques, and the description of the structure, life cycle and immune host response to SARS-CoV-2, and some deeper details of analytical signal detection principles.

3 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
VLViktorija Liustrovaite
Viktorija Liustrovaite
ABAusra Baradoke
Ausra Baradoke
RVRoman Viter
Roman Viter
Chien-Fu ChenChien-Fu Chen
Chien-Fu Chen
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
In this research, we assessed the applicability of electrochemical sensing techniques for detecting specific antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike proteins in the blood serum of patient samples following coronavirus disease 2019 (COVID-19). Herein, screen-printed carbon electrodes (SPCE) with electrodeposited gold nanostructures (AuNS) were modified with L-Cysteine for further covalent immobilization of recombinant SARS-CoV-2 spike proteins (rSpike). The affinity interactions of the rSpike protein with specific antibodies against this protein (anti-rSpike) were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. It was revealed that the SPCE electroactive surface area increased from 1.49 ± 0.02 cm2 to 1.82 ± 0.01 cm2 when AuNS were electrodeposited, and the value of the heterogeneous electron transfer rate constant (k0) changed from 6.30 × 10−5 to 14.56 × 10−5. The performance of the developed electrochemical immunosensor was evaluated by calculating the limit of detection and limit of quantification, giving values of 0.27 nM and 0.81 nM for CV and 0.14 nM and 0.42 nM for DPV. Furthermore, a specificity test was performed with a solution of antibodies against bovine serum albumin as the control aliquot, which was used to assess nonspecific binding, and this evaluation revealed that the developed rSpike-based sensor exhibits low nonspecific binding towards anti-rSpike antibodies.

5 February 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
Vilma RatautaiteVilma Ratautaite
Vilma Ratautaite
EBErnestas Brazys
Ernestas Brazys
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius

Verified
Journal Article
Open access
PDF file
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
VLViktorija Liustrovaite
Viktorija Liustrovaite
ABAusra Baradoke
Ausra Baradoke
ARAlma Rucinskiene
Alma Rucinskiene
Almira RamanavicieneAlmira Ramanaviciene
Almira Ramanaviciene
Arũnas RamanavičiusArũnas Ramanavičius
Arũnas Ramanavičius
The serologic diagnosis of coronavirus disease 2019 (COVID-19) and the evaluation of vaccination effectiveness are identified by the presence of antibodies specific to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this paper, we present the electrochemical-based biosensing technique for the detection of antibodies specific to the SARS-CoV-2 proteins. Recombinant SARS-CoV-2 spike proteins (rSpike) were immobilised on the surface of a gold electrode modified by a self-assembled monolayer (SAM). This modified electrode was used as a sensitive element for the detection of polyclonal mouse antibodies against the rSpike (anti-rSpike). Electrochemical impedance spectroscopy (EIS) was used to observe the formation of immunocomplexes while cyclic voltammetry (CV) was used for additional analysis of the surface modifications. It was revealed that the impedimetric method and the elaborate experimental conditions are appropriate for the further development of electrochemical biosensors for the serological diagnosis of COVID-19 and/or the confirmation of successful vaccination against SARS-CoV-2.

6 September 2019 in Molecular and Cellular Biochemistry
Verified
Journal Article
Closed access
PDF file
NKN. G. Krylova
N. G. Krylova
Maryia DrobyshMaryia Drobysh
Maryia Drobysh
GSG. N. Semenkova
G. N. Semenkova
TKT. A. Kulahava
T. A. Kulahava
SPS. V. Pinchuk
S. V. Pinchuk
OSO. I. Shadyro
O. I. Shadyro