Marian Kučera

Prof. Marian Kučera


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMarie Sejkorová
Marie Sejkorová
MKMarian Kučera
Marian Kučera
IHIvana Hurtová
Ivana Hurtová
OVOndřej Voltr
Ondřej Voltr
Viscosity is considered to be a key factor in the quality of lubrication by oil and engine manufacturers and is therefore one of the most monitored parameters of lubricants. FTIR (Fourier-transform infrared) spectrometry in combination with Partial Least Squares (PLS) and Principal Component Regression (PCR) was therefore proposed and tested as an alternative to the standardized method for determining the kinematic viscosity at 100 °C with an Ubbelohde capillary viscometer (CSN EN ISO 3104) of worn-out motor oil grade SAE 15W-40. The FTIR-PLS model in the spectral region of 1750–650 cm−1 with modification of the spectra by the second derivative proved to be the most suitable. A significant dependence of R = 0.95 was achieved between the viscosity values of 190 samples of worn-out motor oils, which were determined by a standardized laboratory method, and the values predicted by the FTIR-PLS model. The Root Mean Square Error of Calibration (RMSEC) parameter reached 0.148 mm2s−1 and the Root Mean Square Error of Prediction (RMSEP) parameter reached 0.190 mm2s−1. The proposed method for determining the kinematic viscosity at 100 °C by the FTIR-PLS model is faster compared to the determination according to the CSN EN ISO 3104 standard, requires a smaller amount of oil sample for analysis and produces less waste chemicals.

1 September 2015 in Manufacturing Technology
Verified
Journal Article
Open access
PDF file
ZAZdeněk Aleš
Zdeněk Aleš
MPMartin Pexa
Martin Pexa
JPJindřIch Pavlů
JindřIch Pavlů
MKMarian Kučera
Marian Kučera
JČJakub Čedík
Jakub Čedík
Failures of machines are caused by variety of external and internal effects and process that cause ultimately interruption of operation. These factors have resulted in changes of properties of machines parts and these changes are the first cau...

15 May 2025 in Acta Technologica Agriculturae
Verified
Journal Article
Open access
PDF file
MKMarian Kučera
Marian Kučera
JDJakub Drmla
Jakub Drmla
ZAZdeněk Aleš
Zdeněk Aleš
The procedures of tribological diagnostics use oil filling as a resource for multidimensional and complex information about the phenomena, changes, and modes of wear in systems. The purpose was to investigate the possibilities of evaluating two physicochemical parameters [kinematic viscosity at 40 °C (KV40) and total acid number (TAN)] of 6 natural non-edible oils according to chemical composition by means of two methods in laboratory conditions using a tribometer. Evaluation was based on the hypothesis that the oil is considered relatively good if its changes in selected diagnostic properties remain within permissible limits for at least 1000 operating hours. One of the procedures is the assessment of bio-based hydraulic oils on a reciprocal comparison of properties. The following method is based on the monitoring of suitably chosen diagnostic signals that will indirectly rate the technical condition of the oil filling according to changes in the dependent quantities. Results demonstrated that it is possible to assume the degradation of essential oil parameters to the limit condition, to use these data to determine the technical life of the oil filling, and to obtain the trends of relative operating time. In this way, it is possible to give users information about the quality of the oil used in specific operation conditions.

1 October 2017 in Manufacturing Technology
Verified
Journal Article
Open access
PDF file
ZAZdeněk Aleš
Zdeněk Aleš
JPJindřIch Pavlů
JindřIch Pavlů
JSJaroslava Svobodová
Jaroslava Svobodová
MKMarian Kučera
Marian Kučera
MHMonika Hromasová
Monika Hromasová
MPMartin Pexa
Martin Pexa
The design of internal combustion engine use plain bearings, pistons and piston-rod which are based on aluminium, brass. Further are used steels with coating based on aluminium and bronze. The paper describes the impact of contaminants in moto...

3 December 2022 in Machines
Verified
Journal Article
Open access
PDF file
JMJán Melicherčík
Ján Melicherčík
Jozef KrilekJozef Krilek
Jozef Krilek
Ján Kováč,Ján Kováč,
Ján Kováč,
TKTomáš Kuvik
Tomáš Kuvik
MKMarian Kučera
Marian Kučera
This research is focused on the evaluation of cutting edge wear of the delimbing knife by contactless methods. Delimbing knives were tested in an experimental device constructed in our laboratory, which operates on the principle of a forest harvester head. The greatest wear of the cutting edge was manifested in knife no. 1 with a blade angle of ∢ 7°. The research was focused on the wear of delimbing knives made of DIN 58SiCr8/WNr material when changing the angular geometry of the tool and using a constant delimbing speed of 2.0 m.s−1 while delimbing spruce wood of various wood diameters. The Alicona Infinite Focus device, which functions as a non-contact 3D optical device, was used to determine the amount of wear on the cutting edge of the knife. The size of cutting edge wear significantly affects chipless cutting wood, which can be observed in an increase in the cutting force during the delimbing process. The use of harvester technology in forestry is a highly topical issue today. From this point of view, it is necessary to focus on increasing the efficiency and reducing the energy consumption of the machine, which economically benefits its delimbing operation.