Jan Paul Vox

Mr. Jan Paul Vox

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JVJan Paul Vox
Jan Paul Vox
AWAnika Weber
Anika Weber
KWKaren Insa Wolf
Karen Insa Wolf
KIKrzysztof Izdebski
Krzysztof Izdebski
TSThomas Schüler
Thomas Schüler
DFDaniel Friemert
Daniel Friemert
The reproduction and simulation of workplaces, and the analysis of body postures during work processes, are parts of ergonomic risk assessments. A commercial virtual reality (VR) system offers the possibility to model complex work scenarios as virtual mock-ups and to evaluate their ergonomic designs by analyzing motion behavior while performing work processes. In this study a VR tracking sensor system (HTC Vive tracker) combined with an inverse kinematic model (Final IK) was compared with a marker-based optical motion capture system (Qualisys). Marker-based optical motion capture systems are considered the gold standard for motion analysis. Therefore, Qualisys was used as the ground truth in this study. The research question to be answered was how accurately the HTC Vive System combined with Final IK can measure joint angles used for ergonomic evaluation. Twenty-six subjects were observed simultaneously with both tracking systems while performing 20 defined movements. Sixteen joint angles were analyzed. Joint angle deviations between ±6∘ and ±42∘ were identified. These high deviations must be considered in ergonomic risk assessments when using a VR system. The results show that commercial low-budget tracking systems have the potential to map joint angles. Nevertheless, substantial weaknesses and inaccuracies in some body regions must be taken into account. Recommendations are provided to improve tracking accuracy and avoid systematic errors.

31 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LHLars Hornig
Lars Hornig
BSBenedek Szmola
Benedek Szmola
WPWiebke Pätzold
Wiebke Pätzold
JVJan Paul Vox
Jan Paul Vox
KWKaren Insa Wolf
Karen Insa Wolf
Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.

31 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BSBenedek Szmola
Benedek Szmola
LHLars Hornig
Lars Hornig
JVJan Paul Vox
Jan Paul Vox
TLThomas Liman
Thomas Liman
ARAndreas Radeloff
Andreas Radeloff
KWKarsten Witt
Karsten Witt
Simple to use and accurate monitoring of stroke patients’ breathing and heart rate in sleep is needed to lower the risk of secondary strokes and prevent worse functional outcomes due to disturbed sleep. In this study, we computed breathing and heart rates from clinical radar sleep recordings of 49 acute ischemic stroke patients. Parallel polysomnography served as the reference for evaluation. We compared radar rates computed using previously developed multiple and single range bin selection methods. Multiple selection yielded lower mean absolute errors (breathing: 0.39 vs. 0.87 breaths per min; heart rate: 0.84 vs. 3.99 beats per min) and higher correlations with the reference (breathing: 0.95 vs. 0.85; heart rate: 0.96 vs. 0.56). However, single range bin selection produced rates for a larger proportion of recording time (breathing: 93.49% vs. 73.38%; heart rate: 81.85% vs. 19.93%). Our results indicate that multiple range bin selection provides more accurate estimates of breathing and heart rate, but it has lower temporal coverage. Easy to use radar systems could facilitate the clinical adoption of contactless breathing and heart rate monitoring in sleep, improving the care provided to stroke patients.