Lars Hornig

Mr. Lars Hornig

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BSBenedek Szmola
Benedek Szmola
LHLars Hornig
Lars Hornig
KWKaren Insa Wolf
Karen Insa Wolf
ARAndreas Radeloff
Andreas Radeloff
KWKarsten Witt
Karsten Witt
BKBirger Kollmeier
Birger Kollmeier
Radars are promising tools for contactless vital sign monitoring. As a screening device, radars could supplement polysomnography, the gold standard in sleep medicine. When the radar is placed lateral to the person, vital signs can be extracted simultaneously from multiple body parts. Here, we present a method to select every available breathing and heartbeat signal, instead of selecting only one optimal signal. Using multiple concurrent signals can enhance vital rate robustness and accuracy. We built an algorithm based on persistence diagrams, a modern tool for time series analysis from the field of topological data analysis. Multiple criteria were evaluated on the persistence diagrams to detect breathing and heartbeat signals. We tested the feasibility of the method on simultaneous overnight radar and polysomnography recordings from six healthy participants. Compared against single bin selection, multiple selection lead to improved accuracy for both breathing (mean absolute error: 0.29 vs. 0.20 breaths per minute) and heart rate (mean absolute error: 1.97 vs. 0.66 beats per minute). Additionally, fewer artifactual segments were selected. Furthermore, the distribution of chosen vital signs along the body aligned with basic physiological assumptions. In conclusion, contactless vital sign monitoring could benefit from the improved accuracy achieved by multiple selection. The distribution of vital signs along the body could provide additional information for sleep monitoring.

31 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LHLars Hornig
Lars Hornig
BSBenedek Szmola
Benedek Szmola
WPWiebke Pätzold
Wiebke Pätzold
JVJan Paul Vox
Jan Paul Vox
KWKaren Insa Wolf
Karen Insa Wolf
Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.

31 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BSBenedek Szmola
Benedek Szmola
LHLars Hornig
Lars Hornig
JVJan Paul Vox
Jan Paul Vox
TLThomas Liman
Thomas Liman
ARAndreas Radeloff
Andreas Radeloff
KWKarsten Witt
Karsten Witt
Simple to use and accurate monitoring of stroke patients’ breathing and heart rate in sleep is needed to lower the risk of secondary strokes and prevent worse functional outcomes due to disturbed sleep. In this study, we computed breathing and heart rates from clinical radar sleep recordings of 49 acute ischemic stroke patients. Parallel polysomnography served as the reference for evaluation. We compared radar rates computed using previously developed multiple and single range bin selection methods. Multiple selection yielded lower mean absolute errors (breathing: 0.39 vs. 0.87 breaths per min; heart rate: 0.84 vs. 3.99 beats per min) and higher correlations with the reference (breathing: 0.95 vs. 0.85; heart rate: 0.96 vs. 0.56). However, single range bin selection produced rates for a larger proportion of recording time (breathing: 93.49% vs. 73.38%; heart rate: 81.85% vs. 19.93%). Our results indicate that multiple range bin selection provides more accurate estimates of breathing and heart rate, but it has lower temporal coverage. Easy to use radar systems could facilitate the clinical adoption of contactless breathing and heart rate monitoring in sleep, improving the care provided to stroke patients.