Karen Insa Wolf

Dr. Karen Insa Wolf

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JVJan Paul Vox
Jan Paul Vox
AWAnika Weber
Anika Weber
KWKaren Insa Wolf
Karen Insa Wolf
KIKrzysztof Izdebski
Krzysztof Izdebski
TSThomas Schüler
Thomas Schüler
DFDaniel Friemert
Daniel Friemert
The reproduction and simulation of workplaces, and the analysis of body postures during work processes, are parts of ergonomic risk assessments. A commercial virtual reality (VR) system offers the possibility to model complex work scenarios as virtual mock-ups and to evaluate their ergonomic designs by analyzing motion behavior while performing work processes. In this study a VR tracking sensor system (HTC Vive tracker) combined with an inverse kinematic model (Final IK) was compared with a marker-based optical motion capture system (Qualisys). Marker-based optical motion capture systems are considered the gold standard for motion analysis. Therefore, Qualisys was used as the ground truth in this study. The research question to be answered was how accurately the HTC Vive System combined with Final IK can measure joint angles used for ergonomic evaluation. Twenty-six subjects were observed simultaneously with both tracking systems while performing 20 defined movements. Sixteen joint angles were analyzed. Joint angle deviations between ±6∘ and ±42∘ were identified. These high deviations must be considered in ergonomic risk assessments when using a VR system. The results show that commercial low-budget tracking systems have the potential to map joint angles. Nevertheless, substantial weaknesses and inaccuracies in some body regions must be taken into account. Recommendations are provided to improve tracking accuracy and avoid systematic errors.

20 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
BSBenedek Szmola
Benedek Szmola
LHLars Hornig
Lars Hornig
KWKaren Insa Wolf
Karen Insa Wolf
ARAndreas Radeloff
Andreas Radeloff
KWKarsten Witt
Karsten Witt
BKBirger Kollmeier
Birger Kollmeier
Radars are promising tools for contactless vital sign monitoring. As a screening device, radars could supplement polysomnography, the gold standard in sleep medicine. When the radar is placed lateral to the person, vital signs can be extracted simultaneously from multiple body parts. Here, we present a method to select every available breathing and heartbeat signal, instead of selecting only one optimal signal. Using multiple concurrent signals can enhance vital rate robustness and accuracy. We built an algorithm based on persistence diagrams, a modern tool for time series analysis from the field of topological data analysis. Multiple criteria were evaluated on the persistence diagrams to detect breathing and heartbeat signals. We tested the feasibility of the method on simultaneous overnight radar and polysomnography recordings from six healthy participants. Compared against single bin selection, multiple selection lead to improved accuracy for both breathing (mean absolute error: 0.29 vs. 0.20 breaths per minute) and heart rate (mean absolute error: 1.97 vs. 0.66 beats per minute). Additionally, fewer artifactual segments were selected. Furthermore, the distribution of chosen vital signs along the body aligned with basic physiological assumptions. In conclusion, contactless vital sign monitoring could benefit from the improved accuracy achieved by multiple selection. The distribution of vital signs along the body could provide additional information for sleep monitoring.

31 May 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LHLars Hornig
Lars Hornig
BSBenedek Szmola
Benedek Szmola
WPWiebke Pätzold
Wiebke Pätzold
JVJan Paul Vox
Jan Paul Vox
KWKaren Insa Wolf
Karen Insa Wolf
Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.

7 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CSCarlos F. da Silva Souto
Carlos F. da Silva Souto
WPWiebke Pätzold
Wiebke Pätzold
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
AWAxel Winneke
Axel Winneke
SDStefan Debener
Stefan Debener
KWKaren Insa Wolf
Karen Insa Wolf
Most long-term mobile EEG monitoring systems require professional application of the electrodes, which makes them inconvenient for everyday use. Additionally, many materials that facilitate EEG application, such as dry electrodes, may cause discomfort when worn for longer periods of time. To address these problems, we designed flex-printed EEG electrode grids (trEEGrid) and evaluated signal quality based on two pre-applied conductive materials. Self-applicable trEEGrid patches with a conductive solid hydrogel and a novel silicone-based dry material were used in a day-long (5–6 h) recording session, which included a 4 h continuous recording of impedance levels, as well as two auditory task recordings in the morning and afternoon. The signal-to-noise ratio (SNR) of the auditory evoked potentials (AEPs), AEP morphology, and impedance levels of the conductive materials were compared to evaluate overall signal quality, and further comparisons took place between the morning and afternoon sessions to evaluate signal deterioration over time. Comparable impedance values were observed for both silicone and hydrogel materials, but the silicone material exhibited a higher outlier rate, with impedance values over 200 kΩ. Over time, the impedance values increased for the silicone material and decreased for the hydrogel material. The morphology of the AEP was reproduced comparably well with both materials, with reasonable SNRs in both the morning and the afternoon. In conclusion, when combined with flex-printed electrode grids, silicone and hydrogel materials make it feasible to collect high-quality long-term EEG signals with high wearing comfort.

26 April 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
FRFabian Alexander Radke
Fabian Alexander Radke
CSCarlos F. da Silva Souto
Carlos F. da Silva Souto
WPWiebke Pätzold
Wiebke Pätzold
KWKaren Insa Wolf
Karen Insa Wolf
Novel sensor solutions for sleep monitoring at home could alleviate bottlenecks in sleep medical care as well as enable selective or continuous observation over long periods of time and contribute to new insights in sleep medicine and beyond. Since especially in the latter case the sensor data differ strongly in signal, number and extent of sensors from the classical polysomnography (PSG) sensor technology, an automatic evaluation is essential for the application. However, the training of an automatic algorithm is complicated by the fact that the development phase of the new sensor technology, extensive comparative measurements with standardized reference systems, is often not possible and therefore only small datasets are available. In order to circumvent high system-specific training data requirements, we employ pre-training on large datasets with finetuning on small datasets of new sensor technology to enable automatic sleep phase detection for small test series. By pre-training on publicly available PSG datasets and finetuning on 12 nights recorded with new sensor technology based on a pre-gelled electrode grid to capture electroencephalography (EEG), electrooculography (EOG) and electromyography (EMG), an F1 score across all sleep phases of 0.81 is achieved (wake 0.84, N1 0.62, N2 0.81, N3 0.87, REM 0.88), using only EEG and EOG. The analysis additionally considers the spatial distribution of the channels and an approach to approximate classical electrode positions based on specific linear combinations of the new sensor grid channels.