Ander Regueiro

Dr. Ander Regueiro

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in JACC
Verified
Journal Article
Closed access
TRTania Rodriguez-Gabella
Tania Rodriguez-Gabella
PCPablo Catalá
Pablo Catalá
AMAntonio J. Muñoz-García
Antonio J. Muñoz-García
LNLuis Nombela-Franco
Luis Nombela-Franco
RVRaquel Del Valle
Raquel Del Valle
Ignacio J. Amat-SantosIgnacio J. Amat-Santos
Ignacio J. Amat-Santos

18 February 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
RERodrigo Estévez-Loureiro
Rodrigo Estévez-Loureiro
MSMony Shuvy
Mony Shuvy
MTMaurizio Taramasso
Maurizio Taramasso
TBTomás Benito-González
Tomás Benito-González
PDPaolo Denti
Paolo Denti
FMFrancesco Maisano
Francesco Maisano

1 September 2021 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
ODOspedale dell'Angelo
Ospedale dell'Angelo
GGGuglielmo Gallone
Guglielmo Gallone
WKWon-Keun Kim
Won-Keun Kim
JRJoerg Reifart
Joerg Reifart
VVVerena Veulemans
Verena Veulemans
FGFrancesco Giannini
Francesco Giannini
Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.

12 April 2017 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
VAVincent Auffret
Vincent Auffret
ARAnder Regueiro
Ander Regueiro
FCFrancisco Campelo‐Parada
Francisco Campelo‐Parada
MTMaría del Trigo
María del Trigo
OCOlivier Chiche
Olivier Chiche
JRJosep Rodés-Cabau
Josep Rodés-Cabau

1 January 2023 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
Andrea ScottiAndrea Scotti
Andrea Scotti
SBSara Baggio
Sara Baggio
MPMatteo Pagnesi
Matteo Pagnesi
MBMarco Barbanti
Marco Barbanti
MAMarianna Adamo
Marianna Adamo
OIon behalf of the NEOPRO and NEOPRO-2 Investigators‡
on behalf of the NEOPRO and NEOPRO-2 Investigators‡
Background: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. Methods: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. Results: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1–4, 4.1% [2.8–6.3%], 3.7% [2.6–5.3%], 3.3% [2.4–4.9%], 2.9% [2.2–4.3%]; P <0.001) and more moderate or heavy valve calcification (Q1–4, 80%, 80%, 82%, 88%; P =0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1–4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P =0.023) and early safety (Q1–4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P <0.001), with fewer permanent pacemaker implantations (Q1–4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P =0.023) and residual mild or greater paravalvular leaks (Q1–4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P <0.001). Conclusions: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.

13 February 2018 in BMJ Open
Verified
Journal Article
Open access
Ignacio J. Amat-SantosIgnacio J. Amat-Santos
Ignacio J. Amat-Santos
PCPablo Catalá
Pablo Catalá
FHFelipe Diez del Hoyo
Felipe Diez del Hoyo
JFJose A Fernandez-Diaz
Jose A Fernandez-Diaz
JAJuan H Alonso-Briales
Juan H Alonso-Briales
JCJosé Alberto San Román Calvar
José Alberto San Román Calvar
Introduction: Transcatheter aortic valve implantation (TAVI) as a treatment in severe aortic stenosis (AS) is an excellent alternative to conventional surgical replacement. However, long-term outcomes are not benign. Renin-angiotensin system (RAS) blockade has shown benefit in terms of adverse remodelling in severe AS and after surgical replacement. Methods and analysis: The RAS blockade after TAVI (RASTAVI) trial aims to detect if there is a benefit in clinical outcomes and ventricular remodelling with this therapeutic strategy following the TAVI procedure. The study has been designed as a randomised 1:1 open-label study that will be undertaken in 8 centres including 336 TAVI recipients. All patients will receive the standard treatment. The active treatment group will receive ramipril as well. Randomisation will be done before discharge, after signing informed consent. All patients will be followed up for 3 years. A cardiac magnetic resonance will be performed initially and at 1 year to assess ventricular remodelling, defined as ventricular dimensions, ejection fraction, ventricular mass and fibrosis. Recorded events will include cardiac death, admission due to heart failure and stroke. The RASTAVI Study will improve the management of patients after TAVI and may help to increase their quality of life, reduce readmissions and improve long-term survival in this scenario. Ethics and dissemination: All authors and local ethics committees have approved the study design. All patients will provide informed consent. Results will be published irrespective of whether the findings are positive or negative. Trial registration number: NCT03201185 .