Background: An increased degree of aortic angulation (AA) represents a challenging feature for bioprosthesis positioning. Whether AA has an impact on procedural outcomes of contemporary self-expanding valves remains unsettled. The aim of this study was to evaluate the impact of AA on procedural outcomes of transcatheter aortic valve replacement with contemporary self-expanding valves. Methods: The HORSE (Horizontal Aorta in Transcatheter Self-Expanding Valves) is an international, retrospective registry including 3862 consecutive patients undergoing transcatheter aortic valve replacement with either Evolut R/PRO (n=1959) or ACURATE neo (n=1903) devices. Patients undergoing Evolut R 34 mm implantation were excluded as no comparable prosthesis size for ACURATE neo is available. AA was evaluated with preprocedural computed tomography, and its impact on device success was evaluated. Results: In the overall population, AA did not have any impact upon device success, also when adjusting for in-study outcome predictors (odds ratio for 1° increment, 0.99 [95% CI, 0.98–1.01], P =0.306). However, increased AA was associated with lower device success with use of the Evolut R/PRO valves (odds ratio, 0.97 [95% CI, 0.95–0.99]; P =0.004), but not the ACURATE neo valves (odds ratio, 1.00 [95% CI, 0.98–1.03], P =0.304). The best AA cutoff value predicting device success was 49° (47% of the study cohort). Among patients with AA≥49°, Evolut R/PRO valves were associated with lower device success as compared to the ACURATE neo valve (inverse probability weighting odds ratio, 0.62 [95% CI, 0.46–0.83]; P =0.002). Conclusions: Horizontal aorta, as defined by an AA ≥49°, is a common feature among transcatheter aortic valve replacement candidates and predicts device failure of the Evolut R/PRO valves, but not of the ACURATE neo valve. AA may be an effect modifier of the association between self-expanding valve type and device success.
1 January 1993 in Breast Cancer Research and Treatment
Six mechanisms appear to explain poor response to coronary sinus reducer therapy. We hereby review these mechanisms in detail and highlight key areas that should be addressed in order to try and reduce the burden of non-responders following coronary sinus reducer implantation. Rapid Communication from Journal of Invasive Cardiology. chronic coronary disease Interventional cardiology percutaneous coronary intervention refractory angina
Background/Objectives: Aortic stenosis (AS) is the most prevalent valvular heart disease in developed countries and imposes an increasing burden on aging populations. Although transcatheter aortic valve implantation (TAVI) has transformed the treatment of severe AS, current guidelines do not differentiate management based on gender. This study aimed to investigate gender-based differences in procedural complications and one-year clinical outcomes in patients treated with next-generation self-expandable TAVI devices. Methods: This retrospective, multicenter international registry included 3862 consecutive patients who received either the ACURATE neo or Evolut R/Pro valve. Patients were stratified by gender; propensity score matching (PSM) adjusted for baseline differences. The primary endpoint was a composite of all-cause mortality or stroke at one year. Secondary endpoints included major vascular complications, major or life-threatening bleeding and acute kidney injury (AKI). Results: Of 3353 patients included (64.5% female), women were older (82.3 ± 5.6 vs. 81.1 ± 6.2 years, p < 0.001) and had higher STS scores (5.2 ± 3.9 vs. 4.5 ± 3.4%, p < 0.001). In the unmatched population, major vascular complications occurred in 7.7% of females versus 4.1% of males (p < 0.001), life-threatening bleeding in 2.8% vs. 1.4% (p = 0.016) and AKI in 8.5% vs. 5.7% (p = 0.009). After PSM, the primary endpoint was more frequent in females (9.4% vs. 6.0%, p = 0.014), largely driven by stroke (2.8% vs. 1.2%, p = 0.024), while overall mortality was similar (11.3% vs. 9.5%, p = 0.264). Conclusions: Despite comparable long-term survival, female patients undergoing TAVI with self-expandable valves experience higher rates of procedural complications, notably stroke and major vascular events. These findings underscore the need for tailored procedural strategies to improve outcomes in female patients.
9 January 2025 in Cardiovascular Revascularization Medicine