Ewelina Bięga

Ewelina Bięga

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
DFDaniel Firganek
Daniel Firganek
MCMaciej Czerkies
Maciej Czerkies
TLTomasz Lipniacki
Tomasz Lipniacki
MSMarta Skwarecka
Marta Skwarecka
DNDawid Nidzworski
Dawid Nidzworski
This paper presents the development and comparison of label-free electrochemical immunosensors based on screen-printed gold and glassy carbon (GC) disc electrodes for efficient and rapid detection of respiratory syncytial virus (RSV). Briefly, the antibody specific to the F protein of RSV was successfully immobilized on modified electrodes. Antibody coupling on the Au surface was conducted via 4-aminothiophenol (4-ATP) and glutaraldehyde (GA). The GC surface was modified with poly-L-lysine (PLL) for direct anti-RSV conjugation after EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide) activation. Electrochemical characterizations of the immunosensors were carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). GC-based immunosensors show a dynamic range of antigen detection from 1.0 × 105 PFU/mL to 1.5×107 PFU/mL, more than 1.0 × 105 PFU/mL to 1.0 × 107 PFU/mL for the Au-based sensor. However, the GC platform is less sensitive and shows a higher detection limit (LOD) for RSV. The limit of detection of the Au immunosensor is 1.1 × 103 PFU/mL, three orders of magnitude lower than 2.85 × 106 PFU/mL for GC. Thus, the Au-based immunosensor has better analytical performance for virus detection than a carbon-based platform due to high sensitivity and very low RSV detection, obtained with good reproducibility.

7 June 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
KDKarolina Dziąbowska
Karolina Dziąbowska
MLMałgorzata Lisowska
Małgorzata Lisowska
M. Aiman MohtarM. Aiman Mohtar
M. Aiman Mohtar
PMPetr Muller
Petr Muller
DNDawid Nidzworski
Dawid Nidzworski
The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.

16 September 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
MBMateusz Brodowski
Mateusz Brodowski
MKMarcin Kowalski
Marcin Kowalski
WBWioleta Białobrzeska
Wioleta Białobrzeska
KPKatarzyna Pałka
Katarzyna Pałka
RWRafał Walkusz
Rafał Walkusz
DNDawid Nidzworski
Dawid Nidzworski
The study reports a methodology of selecting the optimal receptor to create an electrochemical immunosensor for equine arteritis virus (EAV) protein detection. The detection was based on antigen recognition by antibodies immobilized on gold electrodes. Modification steps were controlled by electrochemical impedance spectroscopy and cyclic voltammetry measurements. In order to obtain the impedance immunosensor with the best parameters, seven different receptors complementary to equine arteritis virus protein were used. In order to make the selection, a rapid screening test was carried out to check the sensor’s response to blank, extremely low and high concentrations of target EAV protein, and negative sample: M protein from Streptococcus equi and glycoprotein G from Equid alphaherpesvirus 1. F6 10G receptor showed the best performance.

19 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
DBDaniel Bigus
Daniel Bigus
WBWioleta Białobrzeska
Wioleta Białobrzeska
EBEwelina Bięga
Ewelina Bięga
AGAnna Grela
Anna Grela
ASAleksandra Siedlar
Aleksandra Siedlar
DNDawid Nidzworski
Dawid Nidzworski
This publication presents the results of work on the development of a quick and cheap electrochemical immunosensor for the diagnosis of infections with the pathogen Streptococcus agalactiae. The research was carried out on the basis of the modification of the well-known glassy carbon (GC) electrodes. The surface of the GC (glassy carbon) electrode was covered with a film made of nanodiamonds, which increased the number of sites for the attachment of anti-Streptococcus agalactiae antibodies. The GC surface was activated with EDC/NHS (1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-Hydroxysuccinimide). Determination of electrode characteristics after each modification step, performed using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS).

9 June 2021
Verified
Journal Article
Open access
PDF file
WBWioleta Białobrzeska
Wioleta Białobrzeska
KDKarolina Dziąbowska
Karolina Dziąbowska
MLMałgorzata Lisowska
Małgorzata Lisowska
M. Aiman MohtarM. Aiman Mohtar
M. Aiman Mohtar
PMPetr Muller
Petr Muller
DNDawid Nidzworski
Dawid Nidzworski
The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.