Yu Chen

Mr. Yu Chen

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2024 in Engineering Failure Analysis
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
ZZZhongyong Zhao
Zhongyong Zhao
JLJiangnan Liu
Jiangnan Liu
STShan Tan
Shan Tan
CLChangqing Liu
Changqing Liu

3 May 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
ZZZhongyong Zhao
Zhongyong Zhao
YCYu Chen
Yu Chen
JLJiangnan Liu
Jiangnan Liu
YCYingying Cheng
Yingying Cheng
CTChao Tang
Chao Tang
CYChenguo Yao
Chenguo Yao
The reliable operating state of smart electricity meters is significant in industrial applications. Faulty meters or meters in a poor measurement state will seriously impact both customers and stakeholders. However, the maintenance personnel now still use the manually periodic sampling inspection from the batch of smart electricity meters to evaluate the state of the entire batch, which has limitations of blindness, poor real-time, inadequate, and insufficient examination. With the population of smart meters, it is feasible to evaluate the health condition of these devices with big data and artificial intelligence (AI) technology. One significant contribution of this study is firstly proposing an operating state evaluation method of smart electricity meters based on the Transformer-Encoder and bidirectional long-term and short-term memory (Transformer-Encoder-BiLSTM). The evaluation indicators and preprocess of meters' data are carefully selected. A deep neural network is constructed and trained, the experimental verification is carried out, and the performance of the proposed method is compared with that of other traditional methods. The results show that the average classification accuracy of the proposed neural network model is 99.5%. Besides, compared with conventional machine learning and deep learning models, the proposed model is suitable for the operation state evaluation of smart electricity meters. From the experimental result, the potential benefit of the proposed method is that it could improve the accuracy and robustness of state evaluation.

15 December 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
ZZZhongyong Zhao
Zhongyong Zhao
YYYueqiang Yu
Yueqiang Yu
WWWei Wang
Wei Wang
CTChao Tang
Chao Tang
Fault diagnosis of the synchronous machine is essential for the safe operation of the modern power system. Recently, impulse frequency response analysis (IFRA) has been used to detect synchronous machine winding short circuit (SC) faults since the failure will significantly alter the IFRA signature of machines. However, there is no standard and reliable code for interpreting the IFRA signatures. It often refers to the frequency response analysis of power transformer standards, the mathematical-statistical indicator of relative factor is directly used to perform the judgment by the standards’ threshold, which might not be appropriate. Besides, the internal mechanism of frequency response analysis diagnosis is unclear. Therefore, this study proposes a technique based on image classification and smooth grade and gradient-based class activation maps (Smooth Grad-CAM++) to understand and interpret the IFRA method. It trains and analyzes the visualization results of the fault data set of a 5kW synchronous machine’s winding. The experimental results show that the average accuracy of the image classification model based on Resnet18 reaches 99.63%. We performed an IFRA difference analysis according to the visualization results and gave some suggestions about IFRA. The training and detection process can be accelerated based on these suggestions. To illustrate the generalization of the suggestions, another 8kW synchronous machine is used for the case study, and the experimental results show that these suggestions are still effective. The main contributions of this study are understanding the internal mechanism of IFRA diagnosis from another perspective and providing some conclusions different from previous research results on the IFRA method for the synchronous machine.

25 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YYYueqiang Yu
Yueqiang Yu
ZZZhongyong Zhao
Zhongyong Zhao
YCYu Chen
Yu Chen
HWHanzhi Wu
Hanzhi Wu
CTChao Tang
Chao Tang
WGWenwen Gu
Wenwen Gu
A machine is a device to realize the mutual conversion of electric energy and mechanical energy. This work mainly discusses the applicability of impulse frequency response analysis (IFRA) to detect the stator winding short circuit faults. The parameters of excitation waveform and signal sampling were carefully selected. A solid-state nanosecond pulsed power source prototype was developed for resonant excitation of windings. The proposed method was then verified on a 5-kVA, 380-V, two-pole, the salient synchronous machine (SM) through artificial fault experiments. Finally, the proposed method was compared with other traditional methods. The method has the advantages of fast measurement, rich high frequencies, high stability, and low cost. Since the principle of IFRA is also applicable to large SMs, this method and device may also be applied to detect large SMs winding short circuit faults. It can be used as an auxiliary and alternative method in the nondestructive fault detection of SMs.

14 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YCYu Chen
Yu Chen
ZZZhongyong Zhao
Zhongyong Zhao
YYYueqiang Yu
Yueqiang Yu
YGYunlong Guo
Yunlong Guo
CTChao Tang
Chao Tang
Winding inter-turn and ground short circuit (SC) faults are common fault types of synchronous machines. The sweep frequency response analysis (SFRA) has been recently introduced to detect winding SC faults. Additionally, impulse FRA (IFRA) provides an alternative that serves the same objective. Whether SFRA or IFRA, so far, there is still no standard and reliable interpretation code. The present interpretation of frequency response still calls for experienced personnel, which could be subjective. Thus, many researchers have used machine or deep learning-based models to detect winding SC faults from the frequency response automatically. However, most proposed models cannot provide real-time feedback and update. Therefore, this study proposes an improved model using life long learning strategy based on incremental classifier and representation learning (iCaRL) to interpret and analyze the IFRA curves. This study artificially simulates and records winding SC faults on a 5 kW synchronous machine. The proposed method is then verified on the test set and compared with other traditional life long learning strategies. The experimental results show that the accuracy of the proposed model is higher than 90% under all types of fault data streams in real-time. The comparative experimental results show that the proposed model performs better than other life long learning strategies. (Github code: https://github.com/cy1034429432/Impro ved-Interpretation-of-IFRA-based-on-iCaRL/tree/main).

19 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YCYu Chen
Yu Chen
XJXiaoqing Ji
Xiaoqing Ji
ZZZhongyong Zhao
Zhongyong Zhao
The accurate establishment of the equivalent circuit model of the synchronous machine windings’ broadband characteristics is the basis for the study of high-frequency machine problems, such as winding fault diagnosis and electromagnetic interference prediction. Therefore, this paper proposes a modeling method for synchronous machine winding based on broadband characteristics. Firstly, the single-phase high-frequency lumped parameter circuit model of synchronous machine winding is introduced, then the broadband characteristics of the port are analyzed by using the state space model, and then the equivalent circuit parameters are identified by using an optimization algorithm combined with the measured broadband impedance characteristics of port. Finally, experimental verification and comparison experiments are carried out on a 5-kW synchronous machine. The experimental results show that the proposed modeling method identifies the impedance curve of the circuit parameters with a high degree of agreement with the measured impedance curve, which indicates that the modeling method is feasible. In addition, the comparative experimental results show that, compared with the engineering exploratory calculation method, the proposed parameter identification method has stronger adaptability to the measured data and a certain robustness. Compared with the black box model, the parameters of the proposed model have a certain physical meaning, and the agreement with the actual impedance characteristic curve is higher than that of the black box model.