15 December 2022 in IEEE Sensors Journal
Fault diagnosis of the synchronous machine is essential for the safe operation of the modern power system. Recently, impulse frequency response analysis (IFRA) has been used to detect synchronous machine winding short circuit (SC) faults since the failure will significantly alter the IFRA signature of machines. However, there is no standard and reliable code for interpreting the IFRA signatures. It often refers to the frequency response analysis of power transformer standards, the mathematical-statistical indicator of relative factor is directly used to perform the judgment by the standards’ threshold, which might not be appropriate. Besides, the internal mechanism of frequency response analysis diagnosis is unclear. Therefore, this study proposes a technique based on image classification and smooth grade and gradient-based class activation maps (Smooth Grad-CAM++) to understand and interpret the IFRA method. It trains and analyzes the visualization results of the fault data set of a 5kW synchronous machine’s winding. The experimental results show that the average accuracy of the image classification model based on Resnet18 reaches 99.63%. We performed an IFRA difference analysis according to the visualization results and gave some suggestions about IFRA. The training and detection process can be accelerated based on these suggestions. To illustrate the generalization of the suggestions, another 8kW synchronous machine is used for the case study, and the experimental results show that these suggestions are still effective. The main contributions of this study are understanding the internal mechanism of IFRA diagnosis from another perspective and providing some conclusions different from previous research results on the IFRA method for the synchronous machine.
3 January 2024 in Medical Physics
20 May 2024 in Physics in Medicine & Biology
Objective . Lowering treatment costs and improving treatment quality are two primary goals for next-generation proton therapy (PT) facilities. This work will design a compact large momentum acceptance superconducting (LMA-SC) gantry beamline to reduce the footprint and expense of the PT facilities, with a novel mixed-size spot scanning method to improve the sparing of organs at risk (OAR). Approach . For the LMA-SC gantry beamline, the movable energy slit is placed in the middle of the last achromatic bending section, and the beam momentum spread of delivered spots can be easily changed during the treatment. Simultaneously, changing the collimator size can provide spots with various lateral spot sizes. Based on the provided large-size and small-size spot models, the treatment planning with mixed spot scanning is optimized: the interior of the target is irradiated with large-size spots (to cover the uniform-dose interior efficiently), while the peripheral of the target is irradiated with small-size spots (to shape the sharp dose falloff at the peripheral accurately). Main results . The treatment plan with mixed-size spot scanning was evaluated and compared with small and large-size spot scanning for thirteen clinical prostate cases. The mixed-size spot plan had superior target dose homogeneities, better protection of OAR, and better plan robustness than the large-size spot plan. Compared to the small-size spot plan, the mixed-size spot plan had comparable plan quality, better plan robustness, and reduced plan delivery time from 65.9 to 40.0 s. Significance . The compact LMA-SC gantry beamline is proposed with mixed-size spot scanning, with demonstrated footprint reduction and improved plan quality compared to the conventional spot scanning method.
15 April 2025 in IEEE Sensors Journal
Winding short-circuit (SC) faults are a prevalent issue in synchronous machines, and the accurate and timely identification of these faults is critical for maintaining power system stability. Current methods for inspecting synchronous machine windings often rely on periodic inspections based on human expertise. Numerous studies have explored the application of deep learning (DL) models for detecting synchronous machine winding SC faults. However, these models often exhibit excessive complexity and overlook physical overhead, leading to inefficient utilization of computational power and data resources. To address these limitations, this study proposes a dual-channel deep learning (DL) model integrated with the active learning (AL) query strategy. In this study, winding SC faults are manually simulated on a 5 kVA synchronous machine, and corresponding frequency response analysis (FRA) data are recorded. Subsequently, the proposed method is validated on the test set and benchmarked against previous studies. Experimental results demonstrate that the proposed method significantly reduces the data annotation effort and accelerates model training to the order of seconds (under 5 seconds) while maintaining satisfactory accuracy (≥ 95%). Comparative experimental results further indicate that the proposed model, requiring only 1/20th of the labeled training samples used in previous studies, achieves a substantial reduction of approximately 99.8% in both model parameters and training time.
30 December 2024 in International Journal of Modern Physics A