Marek Novak

Dr. Marek Novak

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TPTomas Pokorny
Tomas Pokorny
JVJan Vrba
Jan Vrba
Ondrej FiserOndrej Fiser
Ondrej Fiser
DVDavid Vrba
David Vrba
TDTomas Drizdal
Tomas Drizdal
Marco SalucciMarco Salucci
Marco Salucci
The aim of this work was to test microwave brain stroke detection and classification using support vector machines (SVMs). We tested how the nature and variability of training data and system parameters impact the achieved classification accuracy. Using experimentally verified numerical models, a large database of synthetic training and test data was created. The models consist of an antenna array surrounding reconfigurable geometrically and dielectrically realistic human head phantoms with virtually inserted strokes of arbitrary size, and different dielectric parameters in different positions. The generated synthetic data sets were used to test four different hypotheses, regarding the appropriate parameters of the training dataset, the appropriate frequency range and the number of frequency points, as well as the level of subject variability to reach the highest SVM classification accuracy. The results indicate that the SVM algorithm is able to detect the presence of the stroke and classify it (i.e., ischemic or hemorrhagic) even when trained with single-frequency data. Moreover, it is shown that data of subjects with smaller strokes appear to be the most suitable for training accurate SVM predictors with high generalization capabilities. Finally, the datasets created for this study are made available to the community for testing and developing their own algorithms.

30 January 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MNMarek Novak
Marek Novak
JRJozef Rosina
Jozef Rosina
HBHana Bendová
Hana Bendová
KKKristina Kejlová
Kristina Kejlová
AVAlena Vlková
Alena Vlková
JHJan Hajer
Jan Hajer
The research of novel implantable medical devices is one of the most attractive, yet complex areas in the biomedical field. The design and development of sufficiently small devices working in an in vivo environment is challenging but successful encapsulation of such devices is even more so. Industry-standard methods using glass and titanium are too expensive and tedious, and epoxy or silicone encapsulation is prone to water ingress with cable feedthroughs being the most frequent point of failure. This paper describes a universal and straightforward method for reliable encapsulation of circuit boards that achieves ISO10993 compliance. A two-part PVDF mold was machined using a conventional 3-axis machining center. Then, the circuit board with a hermetic feedthrough was placed in the mold and epoxy resin was injected into the mold under pressure to fill the cavity. Finally, the biocompatibility was further enhanced with an inert P3HT polymer coating which can be easily formulated into an ink. The biocompatibility of the encapsulants was assessed according to ISO10993. The endurance of the presented solution compared to silicone potting and epoxy potting was assessed by submersion in phosphate-buffered saline solution at 37 °C. The proposed method showed superior results to PDMS and simple epoxy potting.

7 April 2019 in Gastroenterology Research and Practice
Verified
Journal Article
Open access
PDF file
JHJ. Hajer
J. Hajer
MNMarek Novak
Marek Novak
JRJ. Rosina
J. Rosina
Gastroesophageal reflux disease (GERD) is a rather common disease with a prevalence reaching up to 10 or 20% in the western world. The most specific symptoms which point to the diagnosis of GERD are feelings of heartburn and the regurgitation of acidic stomach contents into the esophagus. However, a certain number of patients do not respond to standard therapy, and in these cases, it is necessary to resort to other treatment methods, such as laparoscopic fundoplication or electrostimulation of the lower esophageal sphincter. The aim of our work was to design and manufacture a miniature, battery-less stimulator to provide electric stimulation of the lower esophageal sphincter, which could be implanted deep into the submucosa of the distal esophagus. The main goal was to provide a battery-less system as opposed to traditional battery neurostimulators to reduce the size and weight of the device. An electronic prototype of a wirelessly powered implantable device was developed. We used animal models for the experiments. The device is designed to treat GERD via electrical stimulation of the muscularis propria. It is implanted into the submucosal pocket by the lower esophageal sphincter with an endoscope. This method of implantation is superior to esophageal stimulators used today because of very low invasiveness of the surgery. Bipolar neurostimulation via two gold-plated leads is provided. The device does not have any source of energy; it is powered wirelessly which reduces the risk of potential battery leakage and reduces the overall dimensions.

1 January 2017 in Gastroenterology Research and Practice
Verified
Journal Article
Open access
PDF file
JHJ. Hajer
J. Hajer
MNMarek Novak
Marek Novak
Gastric dysmotility can be a sign of common diseases such as longstanding diabetes mellitus. It is known that the application of high-frequency low-energetic stimulation can help to effectively moderate and alleviate the symptoms of gastric dysmotility. The goal of our research was the development of a miniature, endoscopically implantable device to a submucosal pocket. The implantable device is a fully customized electronics package which was specifically designed for the purpose of experiments in the submucosa. The device was endoscopically inserted into the submucosal pocket of a pig stomach and partially severed pig side in order to adequately simulate a live animal model. The experiment confirmed that the designed device can be implanted into the submucosa and is capable of the measurement of sensor data and the transmission of this data wirelessly in real time to a computer outside of the body. After proving that the device can be implanted submucosally and transmit data, further experiments can now be performed, primarily with an electrogastrography (EGG) instrument and implantable device with tissue stimulation capability.

16 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
ZLZdenek Linha
Zdenek Linha
JVJan Vrba
Jan Vrba
JKJakub Kollár
Jakub Kollár
Ondrej FiserOndrej Fiser
Ondrej Fiser
TPTomas Pokorny
Tomas Pokorny
DVDavid Vrba
David Vrba
Knowledge of the dielectric parameters of biological tissues is important in a wide range of medical applications of electromagnetic fields. Commercial systems using high-quality vector network analyzers (VNA) are expensive and can be a barrier to the development of existing and emerging applications. Therefore, the main objective of this work was to investigate the potential of using inexpensive VNA, which is available on the market, to measure the dielectric parameters of biological tissues. To accomplish this task, a system for the measurement of dielectric properties of biological tissues in the frequency range from 70 MHz to 3 GHz using inexpensive VNA was developed and presented. The system consists of pocketVNA 2.0 and a custom-made coaxial reflection probe with a diameter of 2.2 mm. The virtual line model of the coaxial probe was used to convert the measured reflection coefficients to the complex permittivity. A total of five ex-vivo tissues (heart, muscle, liver, kidney cortex, and fat) and two standard liquids (isopropanol and ethanol) were measured. The lower accuracy and lower signal-to-noise ratio of the inexpensive VNA were compensated for by post-processing of the measured data, including a time-domain gating and fitting of the evaluated dielectric properties to the Cole-Cole and Debye models for tissues and standard liquids, respectively. The measurement results were compared to the results obtained with a commercial measurement system, and both the standard deviation and mean absolute percentage error (MAPE) are evaluated and presented. The lowest achieved MAPE of biological tissues was for fitted relative permittivity 4.35% (fat, f < 200 MHz) and 0.66% (kidney cortex, f > 200 MHz) and for fitted equivalent electrical conductivity 2.58% (heart, f < 200 MHz) and 3.83% (heart, f > 200 MHz).

27 October 2022 in Cancers
Verified
Journal Article
Open access
PDF file
JKJakub Kollár
Jakub Kollár
TDTomas Drizdal
Tomas Drizdal
JVJan Vrba
Jan Vrba
DVDavid Vrba
David Vrba
TPTomas Pokorny
Tomas Pokorny
Ondrej FiserOndrej Fiser
Ondrej Fiser
Thermal ablation is a well-known method used in interventional radiology to treat cancer. The treatment success is closely related to the exact catheter location in the treated area. Current navigation methods are based mostly on ultrasound or computed tomography. This work explores the possibility of tracking the catheter position during ablation treatment of hepatocellular carcinomas (HCC) using an ultra-wideband (UWB) antenna array and microwave radar imaging based on the “Delay and Sum” (DAS) algorithm. The feasibility was first numerically studied on a simple homogeneous liver model. A heterogeneous anthropomorphic 3D model of the treated region consisting of the main organs within the treated area was then used. Various standard radiofrequency ablation (RFA) catheters were placed virtually in the heterogeneous model. The location and orientation of the antenna elements of the developed imaging system and the applied frequency band were studied. Subsequently, an experimental setup consisting of a 3D printed homogeneous anthropomorphic model, eight UWB dipole antennas, and catheters was created and used in a series of measurements. The average accuracy determining the catheter position from simulated and experimental data was 3.88 ± 0.19 and 6.13 ± 0.66 mm, which are close to the accuracy of clinical navigation systems.