The indoor environment that surrounds us and the elements in it affect not only our mood but also the air quality. Vegetation elements are currently more popular, especially for their aesthetic value but also because of the fact that they affect the physical parameters of the indoor environment such as temperature and humidity. Water elements are a similar example. The presented paper combines these two elements to achieve the best possible level of thermal comfort. Experimental verification of the influence of the living wall on air temperature and humidity took place during the heating season in the city of Brno in the space of the university, while three scenarios were created: the effect of the living wall in a semi-open space, an enclosed space, and a space with a water wall with regulated water temperature. The potential of the water wall is determined based on experimental verification in laboratory conditions. The results show that the synergy of the living and water wall in the indoor space may eliminate the risk of too-low humidity during the heating season.
Addressing climate change necessitates a conscious transition toward sustainable infrastructure solutions. Our vision involved transforming an experimental area into the University Experimental Center. This experimental building serves as a model for gray infrastructure implementation, taking into account its dimensions, layout, flooring, and material composition. Our study aims to compare the retention capacities of various types of vegetated roofs, as determined by different legislations. The findings indicate that the outcomes vary based on the regulations used. This variation subsequently influences the design of associated infrastructures, such as rainwater drainage systems, and the design of stressed structures. This is due to the impact of water quantity on the thermal response of a stressed structure. The water used to irrigate the vegetation layer, along with the water retained by the upper roof, has a positive impact on both the building and its surroundings. Initially, the system comprised two functional components: vegetated roofs and a reference roof. The integrated experimental roof shell, in conjunction with the frame, forms an autonomous system. This system serves as a segment for quantifying water retention, humidity, and temperature across diverse green infrastructure substrates. We analyzed the thermal response of experimental roof constructions and monitored the influence of water and precipitation. Our results indicate that the height of the substrate affects not only the retention capacity but also the thermal response of the vegetated roof.
Water elements with flowing water on the surface are common in buildings as a form of indoor decoration, and they are most often perceived as passive humidifiers. However, by controlling water temperature, they can be also used for air dehumidification. The dehumidification capacity of indoor water elements was investigated experimentally under laboratory conditions. For the experimental verification of dehumidification capacity, a water wall prototype with an effective area of falling water film of 1 m2 and a measuring system were designed and developed. A total of 15 measurements were carried out with air temperatures ranging from 22.1 °C to 32.5 °C and relative humidity from 58.9% to 85.6%. The observed dehumidification capacity varied in the range of 21.99–315.36 g/h for the tested measurements. The results show that the condensation rate is a dynamic process, and the dehumidification capacity of a water wall strongly depends on indoor air parameters (air humidity and temperature). To determine the dehumidification capacity of a water wall for any boundary conditions, the equations were determined based on measured data, and two methods were used: the linear dependence between humidity ratio and condensation rate, and nonlinear surface fitting based on the dependence between the condensation rate, air temperature, and relative humidity.