This paper presents a comprehensive analysis of the potential benefits and feasibility of integrating Building Energy Management Systems (BEMSs) with Building Information Modeling (BIM) in, but not limited to, the construction and building management sectors. By examining advantages, challenges, and real-world case studies, this study offers valuable insights into the impact of BEMS-BIM integration on building operations. The research methodology includes a literature review and bibliometric analysis to understand the subject domain and identify prevalent keywords. Additionally, case studies demonstrate the effectiveness of BEMS-BIM integration in real-world scenarios. This study investigates the possibilities and challenges of BIM to the BEMS methodology for energy-efficient industrial buildings, emphasizing the importance of addressing uncertainties and enhancing software interoperability. This research highlights the potential of BEMS-BIM integration to revolutionize building performance, enhance sustainability, and contribute to a greener and more efficient future for the construction and building management industries.
Accurate determination of river flows and variations is used for the efficient use of water resources, the planning of construction of water structures, and preventing flood disasters. However, accurate flow prediction is related to a good understanding of the hydrological and meteorological characteristics of the river basin. In this study, flow in the river was estimated using Multi Linear Regression (MLR), Artificial Neural Network (ANN), M5 Decision Tree (M5T), Adaptive Neuro-Fuzzy Inference System (ANFIS), Mamdani-Fuzzy Logic (M-FL) and Simple Membership Functions and Fuzzy Rules Generation Technique (SMRGT) models. The Stilwater River in the Sterling region of the USA was selected as the study area and the data obtained from this region were used. Daily rainfall, river flow, and water temperature data were used as input data in all models. In the paper, the performance of the methods is evaluated based on the statistical approach. The results obtained from the generated models were compared with the recorded values. The correlation coefficient (R), Mean Square Error (MSE), and Mean Absolute Error (MAE) statistics are computed separately for each model. According to the comparison criteria, as a final result, it is considered that Mamdani-Fuzzy Logic (M-FL) and Simple Membership Functions and Fuzzy Rules Generation Technique (SMRGT) model have better performance in river flow estimation than the other models.
In 2020, all the world has been confronted with COVID-19. Bringing people together in buildings is proving to be a risk factor that we have to deal with. Although the greatest attention is paid to the SARS-CoV-2 virus, there are a number of other pathogens (viruses, bacteria, fungi, etc.) that can be transmitted through the air. These pathogens are sensitive to UV-C radiation. UV-C fluorescent lamps have been developed with technical parameters that are adapted to HVAC operating conditions. By using germicidal sources to disinfect the transported air, more than 90% of the SARS-CoV-2 virus, more than 97% of Influenza A virus, and 100% of Legionella pneumophila can be inactivated. The use of UV-C emitters for air disinfection allows the use of circulation and recuperation. Total balance of energy and CO2 emissions by variants and energies used, including humidification were performed for Slovak conditions. The operation of germicidal sources during the heating period in selected cities in our example would represent only 0.45% of the difference in heat demand and 0.42% of the difference in energy demand between operation according to recommendations and operation with germicidal sources. It is therefore an effective means of ensuring health safety and energy efficiency for the future.
Energy-efficient buildings, sustainable buildings, smart buildings, nearly zero-energy buildings, passive and active buildings are construction concepts widely recognised as setting the latest trends. The purpose of their design is to create an optimal thermal microclimate by means of heat flows that are either formed within it or enter into it. This research paper presents an analysis of the measurements of the density of heat flows, their spread in building constructions, all of which is examined in laboratory conditions and confronted with calculation models. The hypothesis of this research is to confirm or refute whether the computational models match the laboratory simulations in terms of thermal-technical parameters. The research uses a methodology designed for examining building constructions under virtually stable conditions. Two variants of external sandwich walls based on prefab cross laminated timber panels (variant A) and structural insulated panel (variant B) were proposed as the subject of the study. Both variants were subjected to research in laboratory conditions and computational simulations. For the sake of comparison, the calculation simulations that manufacturers of wood construction systems typically declare were also performed. The results of the analyses show significant differences between the theoretical or declared parameters and the values measured in laboratory conditions (7.5–32.6%). The deviations of the experimental measurements from the calculated or declared parameters were not as significant for variant A as they were for variant B. These findings show that for these analysed sandwich structures based on wood, it is not always possible to reliably declare calculated values of thermal-technical parameters. The publication is also a contribution to the current needs in the field of heating technology in terms of sustainability and the quality of internal environments.
A balanced combination of heat flows creates suitable conditions for thermal comfort—a factor contributing to the quality of the internal environment of buildings. The presented analysis of selected thermal-technical parameters is up-to-date and suitable for verifying the parameters of building constructions. The research also applied a methodology for examining the acoustic parameters of structural parts of buildings in laboratory conditions. In this research, selected variant solutions of perimeter walls based on prefab cross laminated timber were investigated in terms of acoustic and thermal-technical properties. The variants structures were investigated in laboratory but also in model conditions. The results of the analyses show significant differences between the theoretical or declared parameters and the values measured in laboratory conditions. The deviations of experimental measurements from the calculated or declared parameters were not as significant for variant B as they were for variant A. These findings show that for these analyzed sandwich structures based on wood, it is not always possible to reliably declare calculated values of thermal-technical and acoustic parameters. It is necessary to thoroughly examine such design variants, which would contribute to the knowledge in this field of research of construction systems based on wood.
Water elements with flowing water on the surface are common in buildings as a form of indoor decoration, and they are most often perceived as passive humidifiers. However, by controlling water temperature, they can be also used for air dehumidification. The dehumidification capacity of indoor water elements was investigated experimentally under laboratory conditions. For the experimental verification of dehumidification capacity, a water wall prototype with an effective area of falling water film of 1 m2 and a measuring system were designed and developed. A total of 15 measurements were carried out with air temperatures ranging from 22.1 °C to 32.5 °C and relative humidity from 58.9% to 85.6%. The observed dehumidification capacity varied in the range of 21.99–315.36 g/h for the tested measurements. The results show that the condensation rate is a dynamic process, and the dehumidification capacity of a water wall strongly depends on indoor air parameters (air humidity and temperature). To determine the dehumidification capacity of a water wall for any boundary conditions, the equations were determined based on measured data, and two methods were used: the linear dependence between humidity ratio and condensation rate, and nonlinear surface fitting based on the dependence between the condensation rate, air temperature, and relative humidity.