Giovanni Badiali

Prof. Giovanni Badiali

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Laura CercenelliLaura Cercenelli
Laura Cercenelli
ASAlessia De Stefano
Alessia De Stefano
ABAnna Maria Billi
Anna Maria Billi
ARAlessandra Ruggeri
Alessandra Ruggeri
EMEmanuela Marcelli
Emanuela Marcelli
GBGiovanni Badiali
Giovanni Badiali
Gross anatomy knowledge is an essential element for medical students in their education, and nowadays, cadaver-based instruction represents the main instructional tool able to provide three-dimensional (3D) and topographical comprehensions. The aim of the study was to develop and test a prototype of an innovative tool for medical education in human anatomy based on the combination of augmented reality (AR) technology and a tangible 3D printed model that can be explored and manipulated by trainees, thus favoring a three-dimensional and topographical learning approach. After development of the tool, called AEducaAR (Anatomical Education with Augmented Reality), it was tested and evaluated by 62 second-year degree medical students attending the human anatomy course at the International School of Medicine and Surgery of the University of Bologna. Students were divided into two groups: AEducaAR-based learning (“AEducaAR group”) was compared to standard learning using human anatomy atlas (“Control group”). Both groups performed an objective test and an anonymous questionnaire. In the objective test, the results showed no significant difference between the two learning methods; instead, in the questionnaire, students showed enthusiasm and interest for the new tool and highlighted its training potentiality in open-ended comments. Therefore, the presented AEducaAR tool, once implemented, may contribute to enhancing students’ motivation for learning, increasing long-term memory retention and 3D comprehension of anatomical structures. Moreover, this new tool might help medical students to approach to innovative medical devices and technologies useful in their future careers.

11 February 2020 in IEEE Access
Verified
Journal Article
Open access
GBGiovanni Badiali
Giovanni Badiali
Laura CercenelliLaura Cercenelli
Laura Cercenelli
SBSalvatore Battaglia
Salvatore Battaglia
EMEmanuela Marcelli
Emanuela Marcelli
CMClaudio Marchetti
Claudio Marchetti
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
In recent years, there has been an increasing interest towards the augmented reality as applied to the surgical field. We conducted a systematic review of literature classifying the augmented reality applications in oral and cranio-maxillofacial surgery (OCMS) in order to pave the way to future solutions that may ease the adoption of AR guidance in surgical practice. Publications containing the terms “augmented reality” AND “maxillofacial surgery”, and the terms “augmented reality” AND “oral surgery” were searched in the PubMed database. Through the selected studies, we performed a preliminary breakdown according to general aspects, such as surgical subspecialty, year of publication and country of research; then, a more specific breakdown was provided according to technical features of AR-based devices, such as virtual data source, visualization processing mode, tracking mode, registration technique and AR display type. The systematic search identified 30 eligible publications. Most studies (14) were in orthognatic surgery, the minority (2) concerned traumatology, while 6 studies were in oncology and 8 in general OCMS. In 8 of 30 studies the AR systems were based on a head-mounted approach using smart glasses or headsets. In most of these cases (7), a video-see-through mode was implemented, while only 1 study described an optical-see-through mode. In the remaining 22 studies, the AR content was displayed on 2D displays (10), full-parallax 3D displays (6) and projectors (5). In 1 case the AR display type is not specified. AR applications are of increasing interest and adoption in oral and cranio-maxillofacial surgery, however, the quality of the AR experience represents the key requisite for a successful result. Widespread use of AR systems in the operating room may be encouraged by the availability of “surgery-specific” head-mounted devices that should guarantee the accuracy required for surgical tasks and the optimal ergonomics.

5 November 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Laura CercenelliLaura Cercenelli
Laura Cercenelli
MCMarina Carbone
Marina Carbone
Sara CondinoSara Condino
Sara Condino
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
EMEmanuela Marcelli
Emanuela Marcelli
GBGiovanni Badiali
Giovanni Badiali
Background: In the context of guided surgery, augmented reality (AR) represents a groundbreaking improvement. The Video and Optical See-Through Augmented Reality Surgical System (VOSTARS) is a new AR wearable head-mounted display (HMD), recently developed as an advanced navigation tool for maxillofacial and plastic surgery and other non-endoscopic surgeries. In this study, we report results of phantom tests with VOSTARS aimed to evaluate its feasibility and accuracy in performing maxillofacial surgical tasks. Methods: An early prototype of VOSTARS was used. Le Fort 1 osteotomy was selected as the experimental task to be performed under VOSTARS guidance. A dedicated set-up was prepared, including the design of a maxillofacial phantom, an ad hoc tracker anchored to the occlusal splint, and cutting templates for accuracy assessment. Both qualitative and quantitative assessments were carried out. Results: VOSTARS, used in combination with the designed maxilla tracker, showed excellent tracking robustness under operating room lighting. Accuracy tests showed that 100% of Le Fort 1 trajectories were traced with an accuracy of ±1.0 mm, and on average, 88% of the trajectory’s length was within ±0.5 mm accuracy. Conclusions: Our preliminary results suggest that the VOSTARS system can be a feasible and accurate solution for guiding maxillofacial surgical tasks, paving the way to its validation in clinical trials and for a wide spectrum of maxillofacial applications.

12 December 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
FCFrancesco Ceccariglia
Francesco Ceccariglia
Laura CercenelliLaura Cercenelli
Laura Cercenelli
GBGiovanni Badiali
Giovanni Badiali
EMEmanuela Marcelli
Emanuela Marcelli
Achille TarsitanoAchille Tarsitano
Achille Tarsitano
In the relevant global context, although virtual reality, augmented reality, and mixed reality have been emerging methodologies for several years, only now have technological and scientific advances made them suitable for revolutionizing clinical care and medical settings through the provision of advanced features and improved healthcare services. Over the past fifteen years, tools and applications using augmented reality (AR) have been designed and tested in the context of various surgical and medical disciplines, including maxillofacial surgery. The purpose of this paper is to show how a marker-less AR guidance system using the Microsoft® HoloLens 2 can be applied in mandible and maxillary demolition surgery to guide maxillary osteotomies. We describe three mandibular and maxillary oncologic resections performed during 2021 using AR support. In these three patients, we applied a marker-less tracking method based on recognition of the patient’s facial profile. The surgeon, using HoloLens 2 smart glasses, could see the virtual surgical planning superimposed on the patient’s anatomy. We showed that performing osteotomies under AR guidance is feasible and viable, as demonstrated by comparison with osteotomies performed using CAD-CAM cutting guides. This technology has advantages and disadvantages. However, further research is needed to improve the stability and robustness of the marker-less tracking method applied to patient face recognition.

13 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Sara CondinoSara Condino
Sara Condino
BFBenish Fida
Benish Fida
MCMarina Carbone
Marina Carbone
Laura CercenelliLaura Cercenelli
Laura Cercenelli
GBGiovanni Badiali
Giovanni Badiali
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
Augmented reality (AR) Head-Mounted Displays (HMDs) are emerging as the most efficient output medium to support manual tasks performed under direct vision. Despite that, technological and human-factor limitations still hinder their routine use for aiding high-precision manual tasks in the peripersonal space. To overcome such limitations, in this work, we show the results of a user study aimed to validate qualitatively and quantitatively a recently developed AR platform specifically conceived for guiding complex 3D trajectory tracing tasks. The AR platform comprises a new-concept AR video see-through (VST) HMD and a dedicated software framework for the effective deployment of the AR application. In the experiments, the subjects were asked to perform 3D trajectory tracing tasks on 3D-printed replica of planar structures or more elaborated bony anatomies. The accuracy of the trajectories traced by the subjects was evaluated by using templates designed ad hoc to match the surface of the phantoms. The quantitative results suggest that the AR platform could be used to guide high-precision tasks: on average more than 94% of the traced trajectories stayed within an error margin lower than 1 mm. The results confirm that the proposed AR platform will boost the profitable adoption of AR HMDs to guide high precision manual tasks in the peripersonal space.

8 February 2022 in Information
Verified
Journal Article
Open access
PDF file
MCMarina Carbone
Marina Carbone
Fabrizio CutoloFabrizio Cutolo
Fabrizio Cutolo
Sara CondinoSara Condino
Sara Condino
Laura CercenelliLaura Cercenelli
Laura Cercenelli
RDRenzo D'Amato
Renzo D'Amato
Vincenzo FerrariVincenzo Ferrari
Vincenzo Ferrari
In the context of image-guided surgery, augmented reality (AR) represents a ground-breaking enticing improvement, mostly when paired with wearability in the case of open surgery. Commercially available AR head-mounted displays (HMDs), designed for general purposes, are increasingly used outside their indications to develop surgical guidance applications with the ambition to demonstrate the potential of AR in surgery. The applications proposed in the literature underline the hunger for AR-guidance in the surgical room together with the limitations that hinder commercial HMDs from being the answer to such a need. The medical domain demands specifically developed devices that address, together with ergonomics, the achievement of surgical accuracy objectives and compliance with medical device regulations. In the framework of an EU Horizon2020 project, a hybrid video and optical see-through augmented reality headset paired with a software architecture, both specifically designed to be seamlessly integrated into the surgical workflow, has been developed. In this paper, the overall architecture of the system is described. The developed AR HMD surgical navigation platform was positively tested on seven patients to aid the surgeon while performing Le Fort 1 osteotomy in cranio-maxillofacial surgery, demonstrating the value of the hybrid approach and the safety and usability of the navigation platform.