Gross anatomy knowledge is an essential element for medical students in their education, and nowadays, cadaver-based instruction represents the main instructional tool able to provide three-dimensional (3D) and topographical comprehensions. The aim of the study was to develop and test a prototype of an innovative tool for medical education in human anatomy based on the combination of augmented reality (AR) technology and a tangible 3D printed model that can be explored and manipulated by trainees, thus favoring a three-dimensional and topographical learning approach. After development of the tool, called AEducaAR (Anatomical Education with Augmented Reality), it was tested and evaluated by 62 second-year degree medical students attending the human anatomy course at the International School of Medicine and Surgery of the University of Bologna. Students were divided into two groups: AEducaAR-based learning (“AEducaAR group”) was compared to standard learning using human anatomy atlas (“Control group”). Both groups performed an objective test and an anonymous questionnaire. In the objective test, the results showed no significant difference between the two learning methods; instead, in the questionnaire, students showed enthusiasm and interest for the new tool and highlighted its training potentiality in open-ended comments. Therefore, the presented AEducaAR tool, once implemented, may contribute to enhancing students’ motivation for learning, increasing long-term memory retention and 3D comprehension of anatomical structures. Moreover, this new tool might help medical students to approach to innovative medical devices and technologies useful in their future careers.
In recent years, there has been an increasing interest towards the augmented reality as applied to the surgical field. We conducted a systematic review of literature classifying the augmented reality applications in oral and cranio-maxillofacial surgery (OCMS) in order to pave the way to future solutions that may ease the adoption of AR guidance in surgical practice. Publications containing the terms “augmented reality” AND “maxillofacial surgery”, and the terms “augmented reality” AND “oral surgery” were searched in the PubMed database. Through the selected studies, we performed a preliminary breakdown according to general aspects, such as surgical subspecialty, year of publication and country of research; then, a more specific breakdown was provided according to technical features of AR-based devices, such as virtual data source, visualization processing mode, tracking mode, registration technique and AR display type. The systematic search identified 30 eligible publications. Most studies (14) were in orthognatic surgery, the minority (2) concerned traumatology, while 6 studies were in oncology and 8 in general OCMS. In 8 of 30 studies the AR systems were based on a head-mounted approach using smart glasses or headsets. In most of these cases (7), a video-see-through mode was implemented, while only 1 study described an optical-see-through mode. In the remaining 22 studies, the AR content was displayed on 2D displays (10), full-parallax 3D displays (6) and projectors (5). In 1 case the AR display type is not specified. AR applications are of increasing interest and adoption in oral and cranio-maxillofacial surgery, however, the quality of the AR experience represents the key requisite for a successful result. Widespread use of AR systems in the operating room may be encouraged by the availability of “surgery-specific” head-mounted devices that should guarantee the accuracy required for surgical tasks and the optimal ergonomics.
Background: In the context of guided surgery, augmented reality (AR) represents a groundbreaking improvement. The Video and Optical See-Through Augmented Reality Surgical System (VOSTARS) is a new AR wearable head-mounted display (HMD), recently developed as an advanced navigation tool for maxillofacial and plastic surgery and other non-endoscopic surgeries. In this study, we report results of phantom tests with VOSTARS aimed to evaluate its feasibility and accuracy in performing maxillofacial surgical tasks. Methods: An early prototype of VOSTARS was used. Le Fort 1 osteotomy was selected as the experimental task to be performed under VOSTARS guidance. A dedicated set-up was prepared, including the design of a maxillofacial phantom, an ad hoc tracker anchored to the occlusal splint, and cutting templates for accuracy assessment. Both qualitative and quantitative assessments were carried out. Results: VOSTARS, used in combination with the designed maxilla tracker, showed excellent tracking robustness under operating room lighting. Accuracy tests showed that 100% of Le Fort 1 trajectories were traced with an accuracy of ±1.0 mm, and on average, 88% of the trajectory’s length was within ±0.5 mm accuracy. Conclusions: Our preliminary results suggest that the VOSTARS system can be a feasible and accurate solution for guiding maxillofacial surgical tasks, paving the way to its validation in clinical trials and for a wide spectrum of maxillofacial applications.
Cardiac resynchronization therapy (CRT) involves time-consuming procedures to achieve an optimal programming of the system, at implant as well as during follow-up, when remodelling occurs. A device equipped with an implantable sensor able to measure peak endocardial acceleration (PEA) has been recently developed to monitor cardiac function and to guide CRT programming. During scanning of the atrioventricular delay (AVD), PEA reflects both left ventricle (LV) contractility (LV d P /d tmax ) and transmitral flow. A new CRT optimization algorithm, based on recording of PEA (PEA area method) was developed, and compared with measurements of LV d P /d tmax , to identify an optimal CRT configuration. We studied 15 patients in New York Heart Association classes II–IV and with a QRS duration >130 ms, who had undergone implantation of a biventricular (BiV) pulse generator connected to a right ventricular (RV) PEA sensor. At a mean of 39 ± 15 days after implantation of the CRT system, the patients underwent cardiac catheterization. During single-chamber LV or during BiV stimulation, with initial RV or LV stimulation, and at settings of interventricular intervals between 0 and 40 ms, the AVD was scanned between 60 and 220 ms, while LV d P /d tmax and PEA were measured. The area of PEA curve (PEA area method) was estimated as the average of PEA values measured during AVD scanning. A ≥10% increase in LV d P /d tmax was observed in 12 of 15 patients (80%), who were classified as responders to CRT. In nine of 12 responders (75%), the optimal pacing configuration identified by the PEA area method was associated with the greatest LV d P /d tmax . The concordance of the PEA area method with measurements of LV d P /d tmax suggests that this new, operator-independent algorithm is a reliable means of CRT optimization.
In the relevant global context, although virtual reality, augmented reality, and mixed reality have been emerging methodologies for several years, only now have technological and scientific advances made them suitable for revolutionizing clinical care and medical settings through the provision of advanced features and improved healthcare services. Over the past fifteen years, tools and applications using augmented reality (AR) have been designed and tested in the context of various surgical and medical disciplines, including maxillofacial surgery. The purpose of this paper is to show how a marker-less AR guidance system using the Microsoft® HoloLens 2 can be applied in mandible and maxillary demolition surgery to guide maxillary osteotomies. We describe three mandibular and maxillary oncologic resections performed during 2021 using AR support. In these three patients, we applied a marker-less tracking method based on recognition of the patient’s facial profile. The surgeon, using HoloLens 2 smart glasses, could see the virtual surgical planning superimposed on the patient’s anatomy. We showed that performing osteotomies under AR guidance is feasible and viable, as demonstrated by comparison with osteotomies performed using CAD-CAM cutting guides. This technology has advantages and disadvantages. However, further research is needed to improve the stability and robustness of the marker-less tracking method applied to patient face recognition.