Junghwan Back

Junghwan Back

Auto-generated profile, based on publicly available information

Junghwan Back


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2019 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
ZZZhongkai Zhang
Zhongkai Zhang
JDJeremie Dequidt
Jeremie Dequidt
JBJunghwan Back
Junghwan Back
HLHongbin Liu
Hongbin Liu
CDChristian Duriez
Christian Duriez

4 December 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LLLukas Lindenroth
Lukas Lindenroth
RHRichard James Housden
Richard James Housden
Shuangyi WangShuangyi Wang
Shuangyi Wang
JBJunghwan Back
Junghwan Back
Kawal RhodeKawal Rhode
Kawal Rhode
HLHongbin Liu
Hongbin Liu
Objective: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. Methods: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. Results: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of $\mathbf {1.18\pm 0.29}$ mm in position and $\mathbf {0.92\pm 0.47^{\circ }}$ in orientation. The derived controller is, with an average position error of 0.39 mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. Conclusion: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. Significance: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks.

13 October 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YNYohan Noh
Yohan Noh
SSSina Sareh
Sina Sareh
HWHelge Wurdemann
Helge Wurdemann
HLHongbin Liu
Hongbin Liu
JBJunghwan Back
Junghwan Back
Kaspar AlthoeferKaspar Althoefer
Kaspar Althoefer
This paper proposes a force/torque sensor structure that can be easily integrated into a flexible manipulator structure. The sensor's ring-like structure with its hollow inner section provides ample space for auxiliary components, such as cables and tubes, to be passed through and, hence, is very suitable for integration with tendon-driven and fluid-actuated manipulators. The sensor structure can also accommodate the wiring for a distributed sensor system as well as for diagnostic instruments that may be incorporated in the manipulator. Employing a sensing approach based on optical fibers as done here allows for the creation of sensors that are free of electrical currents at the point of sensing and immune to magnetic fields. These sensors are inherently safe when used in the close vicinity of humans and their measuring performance is not impaired when they are operated in or nearby machines, such as magnetic resonance imaging scanners. This type of sensor concept is particularly suitable for inclusion in instruments and robotic tools for minimally invasive surgery. This paper summarizes the design, integration challenges, and calibration of the proposed optical three-axis force sensor. The experimental results confirm the effectiveness of our optical sensing approach and show that after calibrating its stiffness matrix, force and momentum components can be determined accurately.

5 April 2021 in IEEE/CAA Journal of Automatica Sinica
Verified
Journal Article
Closed access
Shuangyi WangShuangyi Wang
Shuangyi Wang
James HousdenJames Housden
James Housden
TBTianxiang Bai
Tianxiang Bai
HLHongbin Liu
Hongbin Liu
JBJunghwan Back
Junghwan Back
FWFei-Yue Wang
Fei-Yue Wang
Robotic intra-operative ultrasound has the potential to improve the conventional practice of diagnosis and procedure guidance that are currently performed manually. Working towards automatic or semi-automatic ultrasound, being able to define ultrasound views and the corresponding probe poses via intelligent approaches become crucial. Based on the concept of parallel system which incorporates the ingredients of artificial systems, computational experiments, and parallel execution, this paper utilized a recent developed robotic trans-esophageal ultrasound system as the study object to explore the method for developing the corresponding virtual environments and present the potential applications of such systems. The proposed virtual system includes the use of 3D slicer as the main workspace and graphic user interface (GUI), Matlab engine to provide robotic control algorithms and customized functions, and PLUS (Public software Library for UltraSound imaging research) toolkit to generate simulated ultrasound images. Detailed implementation methods were presented and the proposed features of the system were explained. Based on this virtual system, example uses and case studies were presented to demonstrate its capabilities when used together with the physical TEE robot. This includes standard view definition and customized view optimization for pre-planning and navigation, as well as robotic control algorithm evaluations to facilitate real-time automatic probe pose adjustments. To conclude, the proposed virtual system would be a powerful tool to facilitate the further developments and clinical uses of the robotic intra-operative ultrasound systems.

18 February 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CYChen Yu
Chen Yu
LLLukas Lindenroth
Lukas Lindenroth
JHJIAN HU
JIAN HU
JBJunghwan Back
Junghwan Back
GAGeorge Abrahams
George Abrahams
HLHongbin Liu
Hongbin Liu
Emulating a human-like somatosensory system in instruments such as robotic hands and surgical grippers has the potential to revolutionize these domains. Using a combination of different sensing modalities is problematic due to the limited space and incompatibility of these sensing principles. Therefore, in contrast to the natural world, it is currently difficult to concurrently measure the force, geometry, and temperature of contact in conventional tactile sensing. To this end, here we present a soft multifunctional tactile sensing principle. The temperature is estimated using a thermochromic liquid crystal ink layer which exhibits colour variation under temperature change. The shape and force of contact is estimated through the 3D reconstruction of a deformed soft silicone surface. Our experiments have demonstrated high accuracy in all three modalities, which can be measured at the same time. The resolution of the distributed force and temperature sensing was found to be 0.7N and 0.4°C respectively.

7 January 2019 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
Shuangyi WangShuangyi Wang
Shuangyi Wang
James HousdenJames Housden
James Housden
YNYohan Noh
Yohan Noh
ASAnisha Singh
Anisha Singh
JBJunghwan Back
Junghwan Back
Kawal RhodeKawal Rhode
Kawal Rhode
With the potential for high precision, dexterity, and repeatability, a self-tracked robotic system can be employed to assist the acquisition of real-time ultrasound. However, limited numbers of robots designed for extra-corporeal ultrasound have been successfully translated into clinical use. In this study, we aim to build a bespoke robotic manipulator for extra-corporeal ultrasound examination, which is lightweight and has a small footprint. The robot is formed by five specially shaped links and custom-made joint mechanisms for probe manipulation, to cover the necessary range of motion with redundant degrees of freedom to ensure the patient's safety. The mechanical safety is emphasized with a clutch mechanism, to limit the force applied to patients. As a result of the design, the total weight of the manipulator is less than 2 kg and the length of the manipulator is about 25 cm. The design has been implemented, and simulation, phantom, and volunteer studies have been performed, to validate the range of motion, the ability to make fine adjustments, mechanical reliability, and the safe operation of the clutch. This paper details the design and implementation of the bespoke robotic ultrasound manipulator, with the design and assembly methods illustrated. Testing results to demonstrate the design features and clinical experience of using the system are presented. It is concluded that the current proposed robotic manipulator meets the requirements as a bespoke system for extra-corporeal ultrasound examination and has great potential to be translated into clinical use.